5.0
2021-08-13T14:31:26Z
9 Templates Group
IPMI_HPDL360G10
IPMI_HPDL360G10
9 Templates Group
CPU
Drives
Fan
Health
LAN
Memory
Power
Temp
-
01-Inlet Ambient
IPMI
01-InletAmbient
300
30d
180d
FLOAT
°C
01-Inlet Ambient
Temp
{last()}>47
Critical Temp Inlet Ambient on {HOSTNAME} (HW)
HIGH
{last()}>42
Error Temp Inlet Ambient on {HOSTNAME} (HW)
AVERAGE
-
02-CPU 1
IPMI
02-CPU1
300
30d
180d
FLOAT
°C
02-CPU 1
CPU
Temp
-
03-CPU 2
IPMI
03-CPU2
300
30d
180d
FLOAT
°C
03-CPU 2
CPU
Temp
-
04-P1 DIMM 1-6
IPMI
04-P1DIMM1-6
300
30d
180d
FLOAT
°C
04-P1 DIMM 1-6
Memory
Temp
-
05-PMM 1-6
IPMI
05-PMM1-6
300
FLOAT
°C
05-PMM 1-6
Temp
-
06-P1 DIMM 7-12
IPMI
06-P1DIMM7-12
300
30d
180d
FLOAT
°C
06-P1 DIMM 7-12
Memory
Temp
-
07-PMM 7-12
IPMI
07-PMM7-12
300
FLOAT
°C
07-PMM 7-12
Temp
-
08-P2 DIMM 1-6
IPMI
08-P2DIMM1-6
300;50/1-7,00:00-24:00
30d
180d
FLOAT
°C
08-P2 DIMM 1-6
Memory
Temp
-
09-PMM 1-6
IPMI
09-PMM1-6
300
FLOAT
°C
09-PMM 1-6
Temp
-
10-P2 DIMM 7-12
IPMI
10-P2DIMM7-12
300
30d
180d
FLOAT
°C
10-P2 DIMM 7-12
Memory
Temp
-
11-PMM 7-12
IPMI
11-PMM7-12
300
FLOAT
°C
11-PMM 7-12
Temp
-
12-HD Max
IPMI
12-HDMax
300
30d
180d
FLOAT
°C
12-HD Max
Temp
{last()}>60
Error Temp HD Max on {HOSTNAME} (HW)
AVERAGE
-
13-Exp Bay Drive
IPMI
13-ExpBayDrive
300
30d
180d
FLOAT
°C
13-Exp Bay Drive
Temp
{last()}>60
Error Temp Exp Bay Drive on {HOSTNAME} (HW)
AVERAGE
-
14-Stor Batt 1
IPMI
14-StorBatt1
300
30d
180d
FLOAT
°C
14-Stor Batt 1
Temp
{last()}>60
Error Temp Stor Batt 1 on {HOSTNAME} (HW)
AVERAGE
-
15-Front Ambient
IPMI
15-FrontAmbient
300
30d
180d
FLOAT
°C
15-Front Ambient
Temp
{last()}>60
Error Temp Front Ambient on {HOSTNAME} (HW)
AVERAGE
-
16-VR P1
IPMI
16-VRP1
300
30d
180d
FLOAT
°C
16-VR P1
Temp
-
17-VR P2
IPMI
17-VRP2
300
30d
180d
FLOAT
°C
17-VR P2
Temp
-
18-VR P1 Mem 1
IPMI
18-VRP1Mem1
300
30d
180d
FLOAT
°C
18-VR P1 Mem 1
Temp
-
19-VR P1 Mem 2
IPMI
19-VRP1Mem2
300
30d
180d
FLOAT
°C
19-VR P1 Mem 2
Temp
-
20-VR P2 Mem 1
IPMI
20-VRP2Mem1
300
30d
180d
FLOAT
°C
20-VR P2 Mem 1
Temp
-
21-VR P2 Mem 2
IPMI
21-VRP2Mem2
300
30d
180d
FLOAT
°C
21-VR P2 Mem 2
Temp
-
22-Chipset
IPMI
22-Chipset
300
30d
180d
FLOAT
°C
22-Chipset
Temp
{last()}>100
Error Temp Chipset on {HOSTNAME} (HW)
AVERAGE
-
23-BMC
IPMI
23-BMC
300
30d
180d
FLOAT
°C
23-BMC
Temp
{last()}>115
Critical Temp BMC on {HOSTNAME} (HW)
HIGH
{last()}>110
Error Temp BMC on {HOSTNAME} (HW)
AVERAGE
-
24-BMC Zone
IPMI
24-BMCZone
300
30d
180d
FLOAT
°C
24-BMC Zone
Temp
{last()}>95
Critical Temp BMC Zone on {HOSTNAME} (HW)
HIGH
{last()}>90
Error Temp BMC Zone on {HOSTNAME} (HW)
AVERAGE
-
25-HD Controller
IPMI
25-HDController
300
30d
180d
FLOAT
°C
25-HD Controller
Temp
{last()}>100
Error Temp HD Controller on {HOSTNAME} (HW)
AVERAGE
-
26-HD Cntlr Zone
IPMI
26-HDCntlrZone
300
30d
180d
FLOAT
°C
26-HD Cntlr Zone
Temp
{last()}>90
Critical Temp HD Cntlr Zone on {HOSTNAME} (HW)
HIGH
{last()}>85
Error Temp HD Cntlr Zone on {HOSTNAME} (HW)
AVERAGE
-
27-LOM
IPMI
27-LOM
300
30d
180d
FLOAT
°C
27-LOM
Temp
-
28-LOM Card
IPMI
28-LOMCard
300
30d
180d
FLOAT
°C
28-LOM Card
Temp
-
29-I/O Zone
IPMI
29-IOZone
300
30d
180d
FLOAT
°C
29-I/O Zone
Temp
{last()}>95
Critical Temp I/O Zone on {HOSTNAME} (HW)
HIGH
{last()}>90
Error Temp I/O Zone on {HOSTNAME} (HW)
AVERAGE
-
30-PCI 1
IPMI
30-PCI1
300
30d
180d
FLOAT
°C
30-PCI 1
Temp
-
31-PCI 1 Zone
IPMI
31-PCI1Zone
300
30d
180d
FLOAT
°C
31-PCI 1 Zone
Temp
-
32-PCI 2
IPMI
32-PCI2
300
30d
180d
FLOAT
°C
32-PCI 2
Temp
-
33-PCI 2 Zone
IPMI
33-PCI2Zone
300
30d
180d
FLOAT
°C
33-PCI 2 Zone
Temp
-
34-PCI 3
IPMI
34-PCI3
300
30d
180d
FLOAT
°C
34-PCI 3
Temp
-
35-PCI 3 Zone
IPMI
35-PCI3Zone
300
30d
180d
FLOAT
°C
35-PCI 3 Zone
Temp
-
37-Rear HD Max
IPMI
37-RearHDMax
300
30d
180d
FLOAT
°C
37-Rear HD Max
Temp
{last()}>60
Error Temp Rear HD Max on {HOSTNAME} (HW)
AVERAGE
-
38-Battery Zone
IPMI
38-BatteryZone
300
30d
180d
FLOAT
°C
38-Battery Zone
Temp
{last()}>80
Critical Temp Battery Zone on {HOSTNAME} (HW)
HIGH
{last()}>75
Error Temp Battery Zone on {HOSTNAME} (HW)
AVERAGE
-
39-P/S 1 Inlet
IPMI
39-PS1Inlet
300
30d
180d
FLOAT
°C
39-P/S 1 Inlet
Temp
-
40-P/S 2 Inlet
IPMI
40-PS2Inlet
300
30d
180d
FLOAT
°C
40-P/S 2 Inlet
Temp
-
41-P/S 1
IPMI
41-PS1
300
30d
180d
FLOAT
°C
41-P/S 1
Temp
-
42-P/S 2
IPMI
42-PS2
300
30d
180d
FLOAT
°C
42-P/S 2
Temp
-
43-E-Fuse
IPMI
43-EFuse
300
30d
180d
FLOAT
°C
43-E-Fuse
Temp
{last()}>100
Error Temp E-Fuse on {HOSTNAME} (HW)
AVERAGE
-
44-P/S 2 Zone
IPMI
44-PS2Zone
300
30d
180d
FLOAT
°C
44-P/S 2 Zone
Temp
{last()}>80
Critical Temp P/S 2 Zone on {HOSTNAME} (HW)
HIGH
{last()}>75
Error Temp P/S 2 Zone on {HOSTNAME} (HW)
AVERAGE
-
61-AHCI HD Max
IPMI
61-AHCIHDMax
300
30d
180d
FLOAT
°C
61-AHCI HD Max
Temp
{last()}>60
Error Temp AHCI HD Max on {HOSTNAME} (HW)
AVERAGE
-
69-PCI 1 M2
IPMI
69-PCI1M2
300
30d
180d
FLOAT
°C
69-PCI 1 M2
Temp
-
70-PCI 1 M2 Zn
IPMI
70-PCI1M2Zn
300
30d
180d
FLOAT
°C
70-PCI 1 M2 Zn
Temp
-
71-PCI 2 M2
IPMI
71-PCI2M2
300
30d
180d
FLOAT
°C
71-PCI 2 M2
Temp
-
72-PCI 2 M2 Zn
IPMI
72-PCI2M2Zn
300
30d
180d
FLOAT
°C
72-PCI 2 M2 Zn
Temp
-
73-PCI 3 M2
IPMI
73-PCI3M2
300
30d
180d
FLOAT
°C
73-PCI 3 M2
Temp
-
74-PCI 3 M2 Zn
IPMI
74-PCI3M2Zn
300
30d
180d
FLOAT
°C
74-PCI 3 M2 Zn
Temp
-
ALOM_Link_P1
IPMI
ALOMLinkP1
300
30d
180d
ALOM_Link_P1
LAN
IPMI LAN
-
ALOM_Link_P2
IPMI
ALOMLinkP2
300
30d
180d
ALOM_Link_P2
LAN
IPMI LAN
-
ALOM_Link_P3
IPMI
ALOMLinkP3
300
30d
180d
ALOM_Link_P3
LAN
IPMI LAN
-
ALOM_Link_P4
IPMI
ALOMLinkP4
300
30d
180d
ALOM_Link_P4
LAN
IPMI LAN
-
CPU_Stat_C1
IPMI
CPUStatC1
600
30d
180d
CPU_Stat_C1
CPU
IPMI Processor
-
CPU_Stat_C2
IPMI
CPUStatC2
600
30d
180d
CPU_Stat_C2
CPU
IPMI Processor
-
CPU Utilization
IPMI
CPUUtilization
60
30d
180d
FLOAT
%
CPU Utilization
CPU
-
Dr_Stat_1I1_B001
IPMI
Dr_Stat_1I1_B001
300
30d
180d
Dr_Stat_1I1_B001
Drives
IPMI Drive Slot (Bay)
{last()}>1
Predictive failure Drive 1 on {HOSTNAME} (HW)
AVERAGE
-
Dr_Stat_1I1_B002
IPMI
Dr_Stat_1I1_B002
300
30d
180d
Dr_Stat_1I1_B002
Drives
IPMI Drive Slot (Bay)
{last()}>1
Predictive failure Drive 2 on {HOSTNAME} (HW)
AVERAGE
-
Dr_Stat_1I1_B003
IPMI
Dr_Stat_1I1_B003
300
30d
180d
Dr_Stat_1I1_B003
Drives
IPMI Drive Slot (Bay)
{last()}>1
Predictive failure Drive 3 on {HOSTNAME} (HW)
AVERAGE
-
Dr_Stat_1I1_B004
IPMI
Dr_Stat_1I1_B004
300
30d
180d
Dr_Stat_1I1_B004
Drives
IPMI Drive Slot (Bay)
{last()}>1
Predictive failure Drive 4 on {HOSTNAME} (HW)
AVERAGE
-
Dr_Stat_2I1_B005
IPMI
Dr_Stat_2I1_B005
300
30d
180d
Dr_Stat_2I1_B005
Drives
IPMI Drive Slot (Bay)
{last()}>1
Predictive failure Drive 5 on {HOSTNAME} (HW)
AVERAGE
-
Dr_Stat_2I1_B006
IPMI
Dr_Stat_2I1_B006
300
30d
180d
Dr_Stat_2I1_B006
Drives
IPMI Drive Slot (Bay)
{last()}>1
Predictive failure Drive 6 on {HOSTNAME} (HW)
AVERAGE
-
Dr_Stat_2I1_B007
IPMI
Dr_Stat_2I1_B007
300
30d
180d
Dr_Stat_2I1_B007
Drives
IPMI Drive Slot (Bay)
{last()}>1
Predictive failure Drive 7 on {HOSTNAME} (HW)
AVERAGE
-
Dr_Stat_2I1_B008
IPMI
Dr_Stat_2I1_B008
300
30d
180d
Dr_Stat_2I1_B008
Drives
IPMI Drive Slot (Bay)
{last()}>1
Predictive failure Drive 8 on {HOSTNAME} (HW)
AVERAGE
-
Fan 1
IPMI
Fan1
300
30d
180d
Fan 1
Fan
IPMI Severity Event States
-
Fan 1 DutyCycle
IPMI
Fan1DutyCycle
300
30d
180d
FLOAT
% Speed
Fan 1 DutyCycle
Fan
-
Fan 1 Presence
IPMI
Fan1Presence
600
30d
180d
Fan 1 Presence
Fan
IPMI Availability Status States
-
Fan 2
IPMI
Fan2
300
30d
180d
FLOAT
Fan 2
Fan
IPMI Severity Event States
-
Fan 2 DutyCycle
IPMI
Fan2DutyCycle
300
30d
180d
FLOAT
% Speed
Fan 2 DutyCycle
Fan
-
Fan 2 Presence
IPMI
Fan2Presence
600
30d
180d
Fan 2 Presence
Fan
IPMI Availability Status States
-
Fan 3
IPMI
Fan3
300
30d
180d
FLOAT
Fan 3
Fan
IPMI Severity Event States
-
Fan 3 DutyCycle
IPMI
Fan3DutyCycle
300
30d
180d
FLOAT
% Speed
Fan 3 DutyCycle
Fan
-
Fan 3 Presence
IPMI
Fan3Presence
600
30d
180d
Fan 3 Presence
Fan
IPMI Availability Status States
-
Fan 4
IPMI
Fan4
300
30d
180d
FLOAT
Fan 4
Fan
IPMI Severity Event States
-
Fan 4 DutyCycle
IPMI
Fan4DutyCycle
300
30d
180d
FLOAT
% Speed
Fan 4 DutyCycle
Fan
-
Fan 4 Presence
IPMI
Fan4Presence
600
30d
180d
Fan 4 Presence
Fan
IPMI Availability Status States
-
Fan 5
IPMI
Fan5
300
30d
180d
FLOAT
Fan 5
Fan
IPMI Severity Event States
-
Fan 5 DutyCycle
IPMI
Fan5DutyCycle
300
30d
180d
FLOAT
% Speed
Fan 5 DutyCycle
Fan
-
Fan 5 Presence
IPMI
Fan5Presence
600
30d
180d
Fan 5 Presence
Fan
IPMI Availability Status States
-
Fan 6
IPMI
Fan6
300
30d
180d
FLOAT
Fan 6
Fan
IPMI Severity Event States
-
Fan 6 DutyCycle
IPMI
Fan6DutyCycle
300
30d
180d
FLOAT
% Speed
Fan 6 DutyCycle
Fan
-
Fan 6 Presence
IPMI
Fan6Presence
600
30d
180d
Fan 6 Presence
Fan
IPMI Availability Status States
-
Fan 7
IPMI
Fan7
300
30d
180d
FLOAT
Fan 7
Fan
IPMI Severity Event States
-
Fan 7 DutyCycle
IPMI
Fan7DutyCycle
300
30d
180d
FLOAT
% Speed
Fan 7 DutyCycle
Fan
-
Fan 7 Presence
IPMI
Fan7Presence
600
30d
180d
Fan 7 Presence
Fan
IPMI Availability Status States
-
Fans
IPMI
Fans
300
30d
180d
Fans
Fan
Health
IPMI Redundancy States
-
Intrusion
IPMI
Intrusion
600
30d
180d
Intrusion
Health
IPMI Physical Security (Chassis Intrusion)
-
LOM_Link_P1
IPMI
LOMLinkP1
300
30d
180d
LOM_Link_P1
LAN
IPMI LAN
-
LOM_Link_P2
IPMI
LOMLinkP2
300
30d
180d
LOM_Link_P2
LAN
IPMI LAN
-
LOM_Link_P3
IPMI
LOMLinkP3
300
30d
180d
LOM_Link_P3
LAN
IPMI LAN
-
LOM_Link_P4
IPMI
LOMLinkP4
300
30d
180d
LOM_Link_P4
LAN
IPMI LAN
-
Megacell Status
IPMI
MegacellStatus
300
30d
180d
Megacell Status
Health
Power
IPMI Battery
{last()}<>4
Check Battery {HOSTNAME} (HW)
AVERAGE
-
Memory Status
IPMI
MemoryStatus
300
30d
180d
Memory Status
Health
Memory
IPMI Memory
{last()}<>64
Memory status changed - need check on {HOSTNAME}
WARNING
-
NIC_Link_01P1
IPMI
NIC_Link_01P1
300
30d
180d
NIC_Link_01P1
LAN
IPMI LAN
-
NIC_Link_01P2
IPMI
NIC_Link_01P2
300
30d
180d
NIC_Link_01P2
LAN
IPMI LAN
-
NIC_Link_01P3
IPMI
NIC_Link_01P3
300
30d
180d
NIC_Link_01P3
LAN
IPMI LAN
-
NIC_Link_01P4
IPMI
NIC_Link_01P4
300
30d
180d
NIC_Link_01P4
LAN
IPMI LAN
-
Power Meter
IPMI
PowerMeter
300
30d
180d
FLOAT
Watts
Power Meter
Power
-
Power Supplies
IPMI
PowerSupplies
120
30d
180d
Power Supplies
Power
IPMI Redundancy States
{last()}<>1
Power Supplies not fully redundant on {HOSTNAME} (HW)
HIGH
-
Power Supply 1
IPMI
PowerSupply1
120
30d
180d
Power Supply 1
Power
IPMI Power Supply
-
Power Supply 2
IPMI
PowerSupply2
120
30d
180d
Power Supply 2
Power
IPMI Power Supply
-
PS 1 Input
IPMI
PS1Input
300
30d
180d
FLOAT
Watts
PS 1 Input
Power
-
PS 1 Output
IPMI
PS1Output
300
30d
180d
FLOAT
Watts
PS 1 Output
Power
-
PS 2 Input
IPMI
PS2Input
300
30d
180d
FLOAT
Watts
PS 2 Input
Power
-
PS 2 Output
IPMI
PS2Output
300
30d
180d
FLOAT
Watts
PS 2 Output
Power
-
PS_Curr_In_01
IPMI
PS_Curr_In_01
300
30d
180d
FLOAT
Amps
PS_Curr_In_01
Power
-
PS_Curr_In_02
IPMI
PS_Curr_In_02
300
30d
180d
FLOAT
Amps
PS_Curr_In_02
Power
-
PS_Curr_Out_01
IPMI
PS_Curr_Out_01
300
30d
180d
FLOAT
Amps
PS_Curr_Out_01
Power
-
PS_Curr_Out_02
IPMI
PS_Curr_Out_02
300
30d
180d
FLOAT
Amps
PS_Curr_Out_02
Power
-
PS_Volt_In_01
IPMI
PS_Volt_In_01
300
30d
180d
FLOAT
Volts
PS_Volt_In_01
Power
-
PS_Volt_In_02
IPMI
PS_Volt_In_02
300
30d
180d
FLOAT
Volts
PS_Volt_In_02
Power
-
PS_Volt_Out_01
IPMI
PS_Volt_Out_01
300
30d
180d
FLOAT
Volts
PS_Volt_Out_01
Power
-
PS_Volt_Out_02
IPMI
PS_Volt_Out_02
300
30d
180d
FLOAT
Volts
PS_Volt_Out_02
Power
-
SysHealth_Stat
IPMI
SysHealthStat
90
30d
180d
SysHealth_Stat
Health
IPMI Severity Event States
{last()}<>1 or {nodata(600)}=1
Error SysHealth_Stat on {HOSTNAME} (HW)
HIGH
-
UID
IPMI
UID
90
30d
180d
UID
Health
IPMI OEM LED UID
{IPMI_HPDL360G10:31-PCI1Zone.last()}>95 or
{IPMI_HPDL360G10:33-PCI2Zone.last()}>95 or
{IPMI_HPDL360G10:35-PCI3Zone.last()}>95
Critical Temp PCI Zone on {HOSTNAME} (HW)
HIGH
{IPMI_HPDL360G10:16-VRP1.last()}>120 or
{IPMI_HPDL360G10:17-VRP2.last()}>120 or
{IPMI_HPDL360G10:18-VRP1Mem1.last()}>120 or
{IPMI_HPDL360G10:19-VRP1Mem2.last()}>120 or
{IPMI_HPDL360G10:20-VRP2Mem1.last()}>120 or
{IPMI_HPDL360G10:21-VRP2Mem2.last()}>120
Critical Temp VR P on {HOSTNAME} (HW)
HIGH
{IPMI_HPDL360G10:PowerSupply1.last()}=0 or {IPMI_HPDL360G10:PowerSupply2.last()}=0
Empty Power Supply on {HOSTNAME} (HW)
AVERAGE
({IPMI_HPDL360G10:CPUStatC1.last()}<>128 and {IPMI_HPDL360G10:CPUStatC1.last()}<>0) or ({IPMI_HPDL360G10:CPUStatC2.last()}<>128 and {IPMI_HPDL360G10:CPUStatC2.last()}<>0)
Error CPU on {HOSTNAME} (HW)
HIGH
{IPMI_HPDL360G10:Fan1.last()}<>1 or {IPMI_HPDL360G10:Fan2.last()}<>1 or {IPMI_HPDL360G10:Fan3.last()}<>1 or {IPMI_HPDL360G10:Fan4.last()}<>1 or {IPMI_HPDL360G10:Fan5.last()}<>1 or {IPMI_HPDL360G10:Fan6.last()}<>1 or
{IPMI_HPDL360G10:Fan7.last()}<>1 or {IPMI_HPDL360G10:Fans.last()}<>1
Error FANS on {HOSTNAME}
AVERAGE
{IPMI_HPDL360G10:PowerSupply1.last()}>1 or {IPMI_HPDL360G10:PowerSupply2.last()}>1
Error Power Supply on {HOSTNAME} (HW)
HIGH
{IPMI_HPDL360G10:02-CPU1.last()}>70 or {IPMI_HPDL360G10:03-CPU2.last()}>70
Error Temp CPU on {HOSTNAME} (HW)
AVERAGE
{IPMI_HPDL360G10:04-P1DIMM1-6.last()}>90 or
{IPMI_HPDL360G10:06-P1DIMM7-12.last()}>90 or
{IPMI_HPDL360G10:08-P2DIMM1-6.last()}>90 or
{IPMI_HPDL360G10:10-P2DIMM7-12.last()}>90
Error Temp DIMM on {HOSTNAME} (HW)
AVERAGE
{IPMI_HPDL360G10:27-LOM.last()}>100 or
{IPMI_HPDL360G10:28-LOMCard.last()}>100
Error Temp LOM on {HOSTNAME} (HW)
AVERAGE
{IPMI_HPDL360G10:69-PCI1M2.last()}>80 or
{IPMI_HPDL360G10:71-PCI2M2.last()}>80 or
{IPMI_HPDL360G10:73-PCI3M2.last()}>80
Error Temp PCI M2 on {HOSTNAME} (HW)
AVERAGE
{IPMI_HPDL360G10:30-PCI1.last()}>100 or
{IPMI_HPDL360G10:32-PCI2.last()}>100 or
{IPMI_HPDL360G10:34-PCI3.last()}>100
Error Temp PCI on {HOSTNAME} (HW)
AVERAGE
{IPMI_HPDL360G10:31-PCI1Zone.last()}>90 or
{IPMI_HPDL360G10:33-PCI2Zone.last()}>90 or
{IPMI_HPDL360G10:35-PCI3Zone.last()}>90
Error Temp PCI Zone on {HOSTNAME} (HW)
AVERAGE
{IPMI_HPDL360G10:05-PMM1-6.last()}>83 or {IPMI_HPDL360G10:07-PMM7-12.last()}>83 or {IPMI_HPDL360G10:09-PMM1-6.last()}>83 or {IPMI_HPDL360G10:11-PMM7-12.last()}>83
Error Temp PMM on {HOSTNAME} (HW)
AVERAGE
{IPMI_HPDL360G10:16-VRP1.last()}>115 or
{IPMI_HPDL360G10:17-VRP2.last()}>115 or
{IPMI_HPDL360G10:18-VRP1Mem1.last()}>115 or
{IPMI_HPDL360G10:19-VRP1Mem2.last()}>115 or
{IPMI_HPDL360G10:20-VRP2Mem1.last()}>115 or
{IPMI_HPDL360G10:21-VRP2Mem2.last()}>115
Error Temp VR P on {HOSTNAME} (HW)
AVERAGE
CPU Utilization
1
1A7C11
-
IPMI_HPDL360G10
CPUUtilization
Fan Speed
1A7C11
-
IPMI_HPDL360G10
Fan1DutyCycle
1
F63100
-
IPMI_HPDL360G10
Fan2DutyCycle
2
2774A4
-
IPMI_HPDL360G10
Fan3DutyCycle
3
A54F10
-
IPMI_HPDL360G10
Fan4DutyCycle
4
FC6EA3
-
IPMI_HPDL360G10
Fan5DutyCycle
5
6C59DC
-
IPMI_HPDL360G10
Fan6DutyCycle
6
AC8C14
-
IPMI_HPDL360G10
Fan7DutyCycle
Power
1
1A7C11
-
IPMI_HPDL360G10
PowerMeter
2
2774A4
-
IPMI_HPDL360G10
PS1Output
3
A54F10
-
IPMI_HPDL360G10
PS2Output
4
A54F10
-
IPMI_HPDL360G10
PS1Input
5
FC6EA3
-
IPMI_HPDL360G10
PS2Input
Temperature
0000EE
-
IPMI_HPDL360G10
02-CPU1
1
00C800
-
IPMI_HPDL360G10
03-CPU2
2
2774A4
-
IPMI_HPDL360G10
01-InletAmbient
3
A54F10
-
IPMI_HPDL360G10
04-P1DIMM1-6
4
FC6EA3
-
IPMI_HPDL360G10
06-P1DIMM7-12
5
6C59DC
-
IPMI_HPDL360G10
08-P2DIMM1-6
6
AC8C14
-
IPMI_HPDL360G10
10-P2DIMM7-12
7
611F27
-
IPMI_HPDL360G10
14-StorBatt1
8
F230E0
-
IPMI_HPDL360G10
15-FrontAmbient
9
5CCD18
-
IPMI_HPDL360G10
22-Chipset
10
BB2A02
-
IPMI_HPDL360G10
39-PS1Inlet
11
5A2B57
-
IPMI_HPDL360G10
40-PS2Inlet
12
89ABF8
-
IPMI_HPDL360G10
23-BMC
13
7EC25C
-
IPMI_HPDL360G10
41-PS1
14
274482
-
IPMI_HPDL360G10
42-PS2
15
2B5429
-
IPMI_HPDL360G10
43-EFuse
16
8048B4
-
IPMI_HPDL360G10
44-PS2Zone
IPMI Availability Status States
1
Device Removed / Device Absent
2
Device Inserted / Device Present
IPMI Battery
1
Battery low (predictive failure)
2
Battery failed
4
Battery presence detected
IPMI Drive Slot (Bay)
1
Drive Present
2
Drive Fault
4
Predictive Failure
8
Hot Spare
16
Consistency Check / Parity Check in progress
32
In Critical Array
33
Drive Present In Critical Array
35
Drive Fault In Critical Array
64
In Failed Array
128
Rebuild/Remap in progress
256
Rebuild/Remap Abortes (was not complete normally)
IPMI LAN
1
LAN Heartbeat Lost
2
LAN Heartbeat
IPMI Memory
1
Correctable ECC
2
Uncorrectable ECC
4
Parity
8
Memory Scrub Failed
16
Memory Device Disabled
32
Correctable ECC / other correctable memory error logging limit r
64
Presence detected
128
Configuration error
256
Spare
512
Memory Automatically Throttled
1024
Critical Overtemperature
IPMI OEM LED UID
1
On
2
Off
4
Blink
IPMI Physical Security (Chassis Intrusion)
0
OK
1
General Chassis Intrusion
2
Drive Bay intrusion
4
I/O Card area intrusion
8
Processor area intrusion
16
LAN Leash Lost
32
Unauthorized dock
64
FAN area intrusion
IPMI Power Supply
0
Power supply not installed
1
Presence detected
2
Failure detected
4
Predictive Failure
8
Input lost (AC/DC)
16
Input lost or out-of-range
32
Input out-of-range but present
64
Configuration error
128
Inactive
IPMI Processor
0
Processor not installed
1
IERR
2
Thermal Trip
4
FRB1/BIST failure
8
FRB2/Hang in POST failure
16
FRB3/Processor Startup/Initialization failure
32
Configuration Error
64
SM BIOS Uncorrectable CPU-complex Error
128
Processor Presence detected
256
Processor disabled
512
Terminator Presence Detected
1024
Processor Automatically Throttled
2048
Machine Check Exception Uncorrectable
4096
Correctable Machine Check Error
IPMI Redundancy States
1
Fully Redundant
2
Redundancy Lost
4
Redundancy Degraded
8
Non-Redundant
16
Non-Redundant
32
Non-Redundant
64
Redundancy Degraded
128
Redundancy Degraded
IPMI Severity Event States
1
Transition to OK
2
Transition to Non-Critical from OK
4
Transition to Critical from less severe
8
Transition to Non-recoverable from less severe
16
Transition to Non-Critical from more severe
32
Transition to Critical from Non-recoverable
64
Transition to Non-recoverable
128
Monitor
256
Informational