<?xml version="1.0" encoding="UTF-8"?>
<zabbix_export>
    <version>5.0</version>
    <date>2021-08-03T14:46:40Z</date>
    <groups>
        <group>
            <name>9 Templates Group</name>
        </group>
    </groups>
    <templates>
        <template>
            <template>IPMI_HPDL380G9</template>
            <name>IPMI_HPDL380G9</name>
            <groups>
                <group>
                    <name>9 Templates Group</name>
                </group>
            </groups>
            <applications>
                <application>
                    <name>Drives</name>
                </application>
                <application>
                    <name>Fan</name>
                </application>
                <application>
                    <name>Health</name>
                </application>
                <application>
                    <name>Power</name>
                </application>
                <application>
                    <name>Temp</name>
                </application>
            </applications>
            <items>
                <item>
                    <name>01-Inlet Ambient</name>
                    <type>IPMI</type>
                    <key>01-InletAmbient</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>°C</units>
                    <ipmi_sensor>01-Inlet Ambient</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Temp</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>02-CPU 1</name>
                    <type>IPMI</type>
                    <key>02-CPU1</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>°C</units>
                    <ipmi_sensor>02-CPU 1</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Temp</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>03-CPU 2</name>
                    <type>IPMI</type>
                    <key>03-CPU2</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>°C</units>
                    <ipmi_sensor>03-CPU 2</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Temp</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>04-P1 DIMM 1-6</name>
                    <type>IPMI</type>
                    <key>04-P1DIMM1-6</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>°C</units>
                    <ipmi_sensor>04-P1 DIMM 1-6</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Temp</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>05-P1 DIMM 7-12</name>
                    <type>IPMI</type>
                    <key>05-P1DIMM7-12</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>°C</units>
                    <ipmi_sensor>05-P1 DIMM 7-12</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Temp</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>06-P2 DIMM 1-6</name>
                    <type>IPMI</type>
                    <key>06-P2DIMM1-6</key>
                    <delay>300;50/1-7,00:00-24:00</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>°C</units>
                    <ipmi_sensor>06-P2 DIMM 1-6</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Temp</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>07-P2 DIMM 7-12</name>
                    <type>IPMI</type>
                    <key>07-P2DIMM7-12</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>°C</units>
                    <ipmi_sensor>07-P2 DIMM 7-12</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Temp</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>08-HD Max</name>
                    <type>IPMI</type>
                    <key>08-HDMax</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>°C</units>
                    <ipmi_sensor>08-HD Max</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Temp</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>09-Exp Bay Drive</name>
                    <type>IPMI</type>
                    <key>09-ExpBayDrive</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>°C</units>
                    <ipmi_sensor>09-Exp Bay Drive</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Temp</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>10-Chipset</name>
                    <type>IPMI</type>
                    <key>10-Chipset</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>°C</units>
                    <ipmi_sensor>10-Chipset</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Temp</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>11-PS 1 Inlet</name>
                    <type>IPMI</type>
                    <key>11-PS1Inlet</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>°C</units>
                    <ipmi_sensor>11-PS 1 Inlet</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Temp</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>12-PS 2 Inlet</name>
                    <type>IPMI</type>
                    <key>12-PS2Inlet</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>°C</units>
                    <ipmi_sensor>12-PS 2 Inlet</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Temp</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>13-VR P1</name>
                    <type>IPMI</type>
                    <key>13-VRP1</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>°C</units>
                    <ipmi_sensor>13-VR P1</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Temp</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>14-VR P2</name>
                    <type>IPMI</type>
                    <key>14-VRP2</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>°C</units>
                    <ipmi_sensor>14-VR P2</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Temp</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>15-VR P1 Mem</name>
                    <type>IPMI</type>
                    <key>15-VRP1Mem</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>°C</units>
                    <ipmi_sensor>15-VR P1 Mem</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Temp</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>16-VR P1 Mem</name>
                    <type>IPMI</type>
                    <key>16-VRP1Mem</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>°C</units>
                    <ipmi_sensor>16-VR P1 Mem</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Temp</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>17-VR P2 Mem</name>
                    <type>IPMI</type>
                    <key>17-VRP2Mem</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>°C</units>
                    <ipmi_sensor>17-VR P2 Mem</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Temp</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>18-VR P2 Mem</name>
                    <type>IPMI</type>
                    <key>18-VRP2Mem</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>°C</units>
                    <ipmi_sensor>18-VR P2 Mem</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Temp</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>19-PS 1 Internal</name>
                    <type>IPMI</type>
                    <key>19-PS1Internal</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>°C</units>
                    <ipmi_sensor>19-PS 1 Internal</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Temp</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>20-PS 2 Internal</name>
                    <type>IPMI</type>
                    <key>20-PS2Internal</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>°C</units>
                    <ipmi_sensor>20-PS 2 Internal</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Temp</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>21-PCI 1</name>
                    <type>IPMI</type>
                    <key>21-PCI1</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>°C</units>
                    <ipmi_sensor>21-PCI 1</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Temp</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>22-PCI 2</name>
                    <type>IPMI</type>
                    <key>22-PCI2</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>°C</units>
                    <ipmi_sensor>22-PCI 2</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Temp</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>23-PCI 3</name>
                    <type>IPMI</type>
                    <key>23-PCI3</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>°C</units>
                    <ipmi_sensor>23-PCI 3</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Temp</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>24-PCI 4</name>
                    <type>IPMI</type>
                    <key>24-PCI4</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>°C</units>
                    <ipmi_sensor>24-PCI 4</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Temp</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>25-PCI 5</name>
                    <type>IPMI</type>
                    <key>25-PCI5</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>°C</units>
                    <ipmi_sensor>25-PCI 5</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Temp</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>26-PCI 6</name>
                    <type>IPMI</type>
                    <key>26-PCI6</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>°C</units>
                    <ipmi_sensor>26-PCI 6</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Temp</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>27-HD Controller</name>
                    <type>IPMI</type>
                    <key>27-HDController</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>°C</units>
                    <ipmi_sensor>27-HD Controller</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Temp</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>28-LOM Card</name>
                    <type>IPMI</type>
                    <key>28-LOMCard</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>°C</units>
                    <ipmi_sensor>28-LOM Card</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Temp</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>29-LOM</name>
                    <type>IPMI</type>
                    <key>29-LOM</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>°C</units>
                    <ipmi_sensor>29-LOM</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Temp</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>30-Front Ambient</name>
                    <type>IPMI</type>
                    <key>30-FrontAmbient</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>°C</units>
                    <ipmi_sensor>30-Front Ambient</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Temp</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>31-PCI 1 Zone</name>
                    <type>IPMI</type>
                    <key>31-PCI1Zone</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>°C</units>
                    <ipmi_sensor>31-PCI 1 Zone.</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Temp</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>32-PCI 2 Zone</name>
                    <type>IPMI</type>
                    <key>32-PCI2Zone</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>°C</units>
                    <ipmi_sensor>32-PCI 2 Zone.</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Temp</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>33-PCI 3 Zone</name>
                    <type>IPMI</type>
                    <key>33-PCI3Zone</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>°C</units>
                    <ipmi_sensor>33-PCI 3 Zone.</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Temp</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>34-PCI 4 Zone</name>
                    <type>IPMI</type>
                    <key>34-PCI4Zone</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>°C</units>
                    <ipmi_sensor>34-PCI 4 Zone</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Temp</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>35-PCI 5 Zone</name>
                    <type>IPMI</type>
                    <key>35-PCI5Zone</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>°C</units>
                    <ipmi_sensor>35-PCI 5 Zone</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Temp</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>36-PCI 6 Zone</name>
                    <type>IPMI</type>
                    <key>36-PCI6Zone</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>°C</units>
                    <ipmi_sensor>36-PCI 6 Zone</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Temp</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>37-HD Cntlr Zone</name>
                    <type>IPMI</type>
                    <key>37-HDCntlrZone</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>°C</units>
                    <ipmi_sensor>37-HD Cntlr Zone</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Temp</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>38-I/O Zone</name>
                    <type>IPMI</type>
                    <key>38-IOZone</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>°C</units>
                    <ipmi_sensor>38-I/O Zone</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Temp</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>39-P/S 2 Zone</name>
                    <type>IPMI</type>
                    <key>39-PS2Zone</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>°C</units>
                    <ipmi_sensor>39-P/S 2 Zone</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Temp</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>40-Battery Zone</name>
                    <type>IPMI</type>
                    <key>40-BatteryZone</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>°C</units>
                    <ipmi_sensor>40-Battery Zone</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Temp</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>41-iLO Zone</name>
                    <type>IPMI</type>
                    <key>41-iLOZone</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>°C</units>
                    <ipmi_sensor>41-iLO Zone</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Temp</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>42-Rear HD Max</name>
                    <type>IPMI</type>
                    <key>42-RearHDMax</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>°C</units>
                    <ipmi_sensor>42-Rear HD Max</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Temp</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>43-Storage Batt</name>
                    <type>IPMI</type>
                    <key>43-StorageBatt</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>°C</units>
                    <ipmi_sensor>43-Storage Batt</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Temp</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>44-Fuse</name>
                    <type>IPMI</type>
                    <key>44-Fuse</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>°C</units>
                    <ipmi_sensor>44-Fuse</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Temp</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>C1 P1I Bay 1</name>
                    <type>IPMI</type>
                    <key>C1P1IBay1</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <ipmi_sensor>C1 P1I Bay 1</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Drives</name>
                        </application>
                    </applications>
                    <valuemap>
                        <name>IPMI Drive Slot (Bay)</name>
                    </valuemap>
                    <triggers>
                        <trigger>
                            <expression>{last()}&gt;1</expression>
                            <name>Predictive failure Drive 1 on {HOSTNAME} (HW)</name>
                            <priority>AVERAGE</priority>
                        </trigger>
                    </triggers>
                </item>
                <item>
                    <name>C1 P1I Bay 2</name>
                    <type>IPMI</type>
                    <key>C1P1IBay2</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <ipmi_sensor>C1 P1I Bay 2</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Drives</name>
                        </application>
                    </applications>
                    <valuemap>
                        <name>IPMI Drive Slot (Bay)</name>
                    </valuemap>
                    <triggers>
                        <trigger>
                            <expression>{last()}&gt;1</expression>
                            <name>Predictive failure Drive 2 on {HOSTNAME} (HW)</name>
                            <priority>AVERAGE</priority>
                        </trigger>
                    </triggers>
                </item>
                <item>
                    <name>C1 P1I Bay 3</name>
                    <type>IPMI</type>
                    <key>C1P1IBay3</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <ipmi_sensor>C1 P1I Bay 3</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Drives</name>
                        </application>
                    </applications>
                    <valuemap>
                        <name>IPMI Drive Slot (Bay)</name>
                    </valuemap>
                    <triggers>
                        <trigger>
                            <expression>{last()}&gt;1</expression>
                            <name>Predictive failure Drive 3 on {HOSTNAME} (HW)</name>
                            <priority>AVERAGE</priority>
                        </trigger>
                    </triggers>
                </item>
                <item>
                    <name>C1 P1I Bay 4</name>
                    <type>IPMI</type>
                    <key>C1P1IBay4</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <ipmi_sensor>C1 P1I Bay 4</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Drives</name>
                        </application>
                    </applications>
                    <valuemap>
                        <name>IPMI Drive Slot (Bay)</name>
                    </valuemap>
                    <triggers>
                        <trigger>
                            <expression>{last()}&gt;1</expression>
                            <name>Predictive failure Drive 4 on {HOSTNAME} (HW)</name>
                            <priority>AVERAGE</priority>
                        </trigger>
                    </triggers>
                </item>
                <item>
                    <name>C1 P1I Bay 5</name>
                    <type>IPMI</type>
                    <key>C1P1IBay5</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <ipmi_sensor>C1 P1I Bay 5</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Drives</name>
                        </application>
                    </applications>
                    <valuemap>
                        <name>IPMI Drive Slot (Bay)</name>
                    </valuemap>
                    <triggers>
                        <trigger>
                            <expression>{last()}&gt;1</expression>
                            <name>Predictive failure Drive 5 on {HOSTNAME} (HW)</name>
                            <priority>AVERAGE</priority>
                        </trigger>
                    </triggers>
                </item>
                <item>
                    <name>C1 P1I Bay 6</name>
                    <type>IPMI</type>
                    <key>C1P1IBay6</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <ipmi_sensor>C1 P1I Bay 6</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Drives</name>
                        </application>
                    </applications>
                    <valuemap>
                        <name>IPMI Drive Slot (Bay)</name>
                    </valuemap>
                    <triggers>
                        <trigger>
                            <expression>{last()}&gt;1</expression>
                            <name>Predictive failure Drive 6 on {HOSTNAME} (HW)</name>
                            <priority>AVERAGE</priority>
                        </trigger>
                    </triggers>
                </item>
                <item>
                    <name>C1 P1I Bay 7</name>
                    <type>IPMI</type>
                    <key>C1P1IBay7</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <ipmi_sensor>C1 P1I Bay 7</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Drives</name>
                        </application>
                    </applications>
                    <valuemap>
                        <name>IPMI Drive Slot (Bay)</name>
                    </valuemap>
                    <triggers>
                        <trigger>
                            <expression>{last()}&gt;1</expression>
                            <name>Predictive failure Drive 7 on {HOSTNAME} (HW)</name>
                            <priority>AVERAGE</priority>
                        </trigger>
                    </triggers>
                </item>
                <item>
                    <name>C1 P1I Bay 8</name>
                    <type>IPMI</type>
                    <key>C1P1IBay8</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <ipmi_sensor>C1 P1I Bay 8</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Drives</name>
                        </application>
                    </applications>
                    <valuemap>
                        <name>IPMI Drive Slot (Bay)</name>
                    </valuemap>
                    <triggers>
                        <trigger>
                            <expression>{last()}&gt;1</expression>
                            <name>Predictive failure Drive 8 on {HOSTNAME} (HW)</name>
                            <priority>AVERAGE</priority>
                        </trigger>
                    </triggers>
                </item>
                <item>
                    <name>C1 P2I Bay 1</name>
                    <type>IPMI</type>
                    <key>C1P2IBay1</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <ipmi_sensor>C1 P2I Bay 1</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Drives</name>
                        </application>
                    </applications>
                    <valuemap>
                        <name>IPMI Drive Slot (Bay)</name>
                    </valuemap>
                    <triggers>
                        <trigger>
                            <expression>{last()}&gt;1</expression>
                            <name>Predictive failure Drive 9 on {HOSTNAME} (HW)</name>
                            <priority>AVERAGE</priority>
                        </trigger>
                    </triggers>
                </item>
                <item>
                    <name>C1 P2I Bay 2</name>
                    <type>IPMI</type>
                    <key>C1P2IBay2</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <ipmi_sensor>C1 P2I Bay 2</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Drives</name>
                        </application>
                    </applications>
                    <valuemap>
                        <name>IPMI Drive Slot (Bay)</name>
                    </valuemap>
                    <triggers>
                        <trigger>
                            <expression>{last()}&gt;1</expression>
                            <name>Predictive failure Drive 10 on {HOSTNAME} (HW)</name>
                            <priority>AVERAGE</priority>
                        </trigger>
                    </triggers>
                </item>
                <item>
                    <name>C1 P2I Bay 3</name>
                    <type>IPMI</type>
                    <key>C1P2IBay3</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <ipmi_sensor>C1 P2I Bay 3</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Drives</name>
                        </application>
                    </applications>
                    <valuemap>
                        <name>IPMI Drive Slot (Bay)</name>
                    </valuemap>
                    <triggers>
                        <trigger>
                            <expression>{last()}&gt;1</expression>
                            <name>Predictive failure Drive 11 on {HOSTNAME} (HW)</name>
                            <priority>AVERAGE</priority>
                        </trigger>
                    </triggers>
                </item>
                <item>
                    <name>C1 P2I Bay 4</name>
                    <type>IPMI</type>
                    <key>C1P2IBay4</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <ipmi_sensor>C1 P2I Bay 4</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Drives</name>
                        </application>
                    </applications>
                    <valuemap>
                        <name>IPMI Drive Slot (Bay)</name>
                    </valuemap>
                    <triggers>
                        <trigger>
                            <expression>{last()}&gt;1</expression>
                            <name>Predictive failure Drive 12 on {HOSTNAME} (HW)</name>
                            <priority>AVERAGE</priority>
                        </trigger>
                    </triggers>
                </item>
                <item>
                    <name>Fan 1</name>
                    <type>IPMI</type>
                    <key>Fan1</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <ipmi_sensor>Fan 1</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Fan</name>
                        </application>
                    </applications>
                    <valuemap>
                        <name>IPMI Severity Event States</name>
                    </valuemap>
                </item>
                <item>
                    <name>Fan 1 DutyCycle</name>
                    <type>IPMI</type>
                    <key>Fan1DutyCycle</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>% Speed</units>
                    <ipmi_sensor>Fan 1 DutyCycle</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Fan</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>Fan 1 Presence</name>
                    <type>IPMI</type>
                    <key>Fan1Presence</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <ipmi_sensor>Fan 1 Presence</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Fan</name>
                        </application>
                    </applications>
                    <valuemap>
                        <name>IPMI Availability Status States</name>
                    </valuemap>
                </item>
                <item>
                    <name>Fan 2</name>
                    <type>IPMI</type>
                    <key>Fan2</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <ipmi_sensor>Fan 2</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Fan</name>
                        </application>
                    </applications>
                    <valuemap>
                        <name>IPMI Severity Event States</name>
                    </valuemap>
                </item>
                <item>
                    <name>Fan 2 DutyCycle</name>
                    <type>IPMI</type>
                    <key>Fan2DutyCycle</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>% Speed</units>
                    <ipmi_sensor>Fan 2 DutyCycle</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Fan</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>Fan 2 Presence</name>
                    <type>IPMI</type>
                    <key>Fan2Presence</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <ipmi_sensor>Fan 2 Presence</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Fan</name>
                        </application>
                    </applications>
                    <valuemap>
                        <name>IPMI Availability Status States</name>
                    </valuemap>
                </item>
                <item>
                    <name>Fan 3</name>
                    <type>IPMI</type>
                    <key>Fan3</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <ipmi_sensor>Fan 3</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Fan</name>
                        </application>
                    </applications>
                    <valuemap>
                        <name>IPMI Severity Event States</name>
                    </valuemap>
                </item>
                <item>
                    <name>Fan 3 DutyCycle</name>
                    <type>IPMI</type>
                    <key>Fan3DutyCycle</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>% Speed</units>
                    <ipmi_sensor>Fan 3 DutyCycle</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Fan</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>Fan 3 Presence</name>
                    <type>IPMI</type>
                    <key>Fan3Presence</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <ipmi_sensor>Fan 3 Presence</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Fan</name>
                        </application>
                    </applications>
                    <valuemap>
                        <name>IPMI Availability Status States</name>
                    </valuemap>
                </item>
                <item>
                    <name>Fan 4</name>
                    <type>IPMI</type>
                    <key>Fan4</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <ipmi_sensor>Fan 4</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Fan</name>
                        </application>
                    </applications>
                    <valuemap>
                        <name>IPMI Severity Event States</name>
                    </valuemap>
                </item>
                <item>
                    <name>Fan 4 DutyCycle</name>
                    <type>IPMI</type>
                    <key>Fan4DutyCycle</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>% Speed</units>
                    <ipmi_sensor>Fan 4 DutyCycle</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Fan</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>Fan 4 Presence</name>
                    <type>IPMI</type>
                    <key>Fan4Presence</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <ipmi_sensor>Fan 4 Presence</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Fan</name>
                        </application>
                    </applications>
                    <valuemap>
                        <name>IPMI Availability Status States</name>
                    </valuemap>
                </item>
                <item>
                    <name>Fan 5</name>
                    <type>IPMI</type>
                    <key>Fan5</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <ipmi_sensor>Fan 5</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Fan</name>
                        </application>
                    </applications>
                    <valuemap>
                        <name>IPMI Severity Event States</name>
                    </valuemap>
                </item>
                <item>
                    <name>Fan 5 DutyCycle</name>
                    <type>IPMI</type>
                    <key>Fan5DutyCycle</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>% Speed</units>
                    <ipmi_sensor>Fan 5 DutyCycle</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Fan</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>Fan 5 Presence</name>
                    <type>IPMI</type>
                    <key>Fan5Presence</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <ipmi_sensor>Fan 5 Presence</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Fan</name>
                        </application>
                    </applications>
                    <valuemap>
                        <name>IPMI Availability Status States</name>
                    </valuemap>
                </item>
                <item>
                    <name>Fan 6</name>
                    <type>IPMI</type>
                    <key>Fan6</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <ipmi_sensor>Fan 6</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Fan</name>
                        </application>
                    </applications>
                    <valuemap>
                        <name>IPMI Severity Event States</name>
                    </valuemap>
                </item>
                <item>
                    <name>Fan 6 DutyCycle</name>
                    <type>IPMI</type>
                    <key>Fan6DutyCycle</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>% Speed</units>
                    <ipmi_sensor>Fan 6 DutyCycle</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Fan</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>Fan 6 Presence</name>
                    <type>IPMI</type>
                    <key>Fan6Presence</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <ipmi_sensor>Fan 6 Presence</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Fan</name>
                        </application>
                    </applications>
                    <valuemap>
                        <name>IPMI Availability Status States</name>
                    </valuemap>
                </item>
                <item>
                    <name>Fans</name>
                    <type>IPMI</type>
                    <key>Fans</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <ipmi_sensor>Fans</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Health</name>
                        </application>
                    </applications>
                    <valuemap>
                        <name>IPMI Severity Event States</name>
                    </valuemap>
                </item>
                <item>
                    <name>Megacell Status</name>
                    <type>IPMI</type>
                    <key>MegacellStatus</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <ipmi_sensor>Megacell Status</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Health</name>
                        </application>
                    </applications>
                    <valuemap>
                        <name>IPMI Battery</name>
                    </valuemap>
                    <triggers>
                        <trigger>
                            <expression>{last()}&lt;&gt;4</expression>
                            <name>Check Battery {HOSTNAME} (HW)</name>
                            <priority>AVERAGE</priority>
                        </trigger>
                    </triggers>
                </item>
                <item>
                    <name>Memory Status</name>
                    <type>IPMI</type>
                    <key>MemoryStatus</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <ipmi_sensor>Memory Status</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Health</name>
                        </application>
                    </applications>
                    <valuemap>
                        <name>IPMI Memory</name>
                    </valuemap>
                    <triggers>
                        <trigger>
                            <expression>{last()}&lt;&gt;64</expression>
                            <name>Memory status changed - need check on {HOSTNAME}</name>
                            <priority>WARNING</priority>
                        </trigger>
                    </triggers>
                </item>
                <item>
                    <name>Power Meter</name>
                    <type>IPMI</type>
                    <key>PowerMeter</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <ipmi_sensor>Power Meter</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Power</name>
                        </application>
                    </applications>
                    <valuemap>
                        <name>IPMI Availability Status States</name>
                    </valuemap>
                </item>
                <item>
                    <name>Power Supplies</name>
                    <type>IPMI</type>
                    <key>PowerSupplies</key>
                    <delay>120</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <ipmi_sensor>Power Supplies</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Power</name>
                        </application>
                    </applications>
                    <valuemap>
                        <name>IPMI Redundancy States</name>
                    </valuemap>
                </item>
                <item>
                    <name>Power Supply 1</name>
                    <type>IPMI</type>
                    <key>PowerSupply1</key>
                    <delay>120</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <ipmi_sensor>Power Supply 1</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Power</name>
                        </application>
                    </applications>
                    <valuemap>
                        <name>IPMI Power Supply</name>
                    </valuemap>
                </item>
                <item>
                    <name>Power Supply 2</name>
                    <type>IPMI</type>
                    <key>PowerSupply2</key>
                    <delay>120</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <ipmi_sensor>Power Supply 2</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Power</name>
                        </application>
                    </applications>
                    <valuemap>
                        <name>IPMI Power Supply</name>
                    </valuemap>
                </item>
                <item>
                    <name>PS 1 Output</name>
                    <type>IPMI</type>
                    <key>PS1Output</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>Watts</units>
                    <ipmi_sensor>PS 1 Output</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Power</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>PS 1 Presence</name>
                    <type>IPMI</type>
                    <key>PS1Presence</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <ipmi_sensor>PS 1 Presence</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Power</name>
                        </application>
                    </applications>
                    <valuemap>
                        <name>IPMI Availability Status States</name>
                    </valuemap>
                </item>
                <item>
                    <name>PS 2 Output</name>
                    <type>IPMI</type>
                    <key>PS2Output</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>Watts</units>
                    <ipmi_sensor>PS 2 Output</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Power</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>PS 2 Presence</name>
                    <type>IPMI</type>
                    <key>PS2Presence</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <ipmi_sensor>PS 2 Presence</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Power</name>
                        </application>
                    </applications>
                    <valuemap>
                        <name>IPMI Availability Status States</name>
                    </valuemap>
                </item>
                <item>
                    <name>PwrMeter Output</name>
                    <type>IPMI</type>
                    <key>PwrMeterOutput</key>
                    <delay>300</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <value_type>FLOAT</value_type>
                    <units>Watts</units>
                    <ipmi_sensor>PwrMeter Output</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Power</name>
                        </application>
                    </applications>
                </item>
                <item>
                    <name>Sys Health LED</name>
                    <type>IPMI</type>
                    <key>SysHealthLED</key>
                    <delay>90</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <ipmi_sensor>Sys Health LED</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Health</name>
                        </application>
                    </applications>
                    <valuemap>
                        <name>IPMI Severity Event States</name>
                    </valuemap>
                    <triggers>
                        <trigger>
                            <expression>{last()}&lt;&gt;1 or {nodata(600)}=1</expression>
                            <name>Error Sys. Health LED on {HOSTNAME} (HW)</name>
                            <priority>HIGH</priority>
                        </trigger>
                    </triggers>
                </item>
                <item>
                    <name>UID</name>
                    <type>IPMI</type>
                    <key>UID</key>
                    <delay>90</delay>
                    <history>30d</history>
                    <trends>180d</trends>
                    <ipmi_sensor>UID</ipmi_sensor>
                    <applications>
                        <application>
                            <name>Health</name>
                        </application>
                    </applications>
                    <valuemap>
                        <name>IPMI OEM LED UID</name>
                    </valuemap>
                </item>
            </items>
        </template>
    </templates>
    <triggers>
        <trigger>
            <expression>{IPMI_HPDL380G9:PowerSupply1.last()}=0 or {IPMI_HPDL380G9:PowerSupply2.last()}=0</expression>
            <name>Empty Power Supply on {HOSTNAME} (HW)</name>
            <priority>HIGH</priority>
        </trigger>
        <trigger>
            <expression>{IPMI_HPDL380G9:Fan1.last()}=0 or {IPMI_HPDL380G9:Fan2.last()}=0 or {IPMI_HPDL380G9:Fan3.last()}=0 or {IPMI_HPDL380G9:Fan4.last()}=0 or {IPMI_HPDL380G9:Fan5.last()}=0 or {IPMI_HPDL380G9:Fan6.last()}=0</expression>
            <name>Error FANS on {HOSTNAME}</name>
            <priority>AVERAGE</priority>
        </trigger>
        <trigger>
            <expression>{IPMI_HPDL380G9:PowerSupply1.last()}&gt;1 or {IPMI_HPDL380G9:PowerSupply2.last()}&gt;1</expression>
            <name>Error Power Supply on {HOSTNAME} (HW)</name>
            <priority>HIGH</priority>
        </trigger>
        <trigger>
            <expression>{IPMI_HPDL380G9:02-CPU1.last()}&gt;70 or {IPMI_HPDL380G9:03-CPU2.last()}&gt;70</expression>
            <name>Error Temp CPU on {HOSTNAME} (HW)</name>
            <priority>HIGH</priority>
        </trigger>
    </triggers>
    <graphs>
        <graph>
            <name>Fan Speed</name>
            <graph_items>
                <graph_item>
                    <sortorder>1</sortorder>
                    <color>1A7C11</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>Fan1DutyCycle</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>2</sortorder>
                    <color>F63100</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>Fan2DutyCycle</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>3</sortorder>
                    <color>2774A4</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>Fan3DutyCycle</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>4</sortorder>
                    <color>A54F10</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>Fan4DutyCycle</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>5</sortorder>
                    <color>FC6EA3</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>Fan5DutyCycle</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>6</sortorder>
                    <color>6C59DC</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>Fan6DutyCycle</key>
                    </item>
                </graph_item>
            </graph_items>
        </graph>
        <graph>
            <name>Power</name>
            <graph_items>
                <graph_item>
                    <sortorder>1</sortorder>
                    <color>1A7C11</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>PS1Output</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>2</sortorder>
                    <color>F63100</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>PS2Output</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>3</sortorder>
                    <color>2774A4</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>PwrMeterOutput</key>
                    </item>
                </graph_item>
            </graph_items>
        </graph>
        <graph>
            <name>Temperature</name>
            <graph_items>
                <graph_item>
                    <sortorder>1</sortorder>
                    <color>1A7C11</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>01-InletAmbient</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>2</sortorder>
                    <color>F63100</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>02-CPU1</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>3</sortorder>
                    <color>2774A4</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>03-CPU2</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>4</sortorder>
                    <color>A54F10</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>04-P1DIMM1-6</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>5</sortorder>
                    <color>FC6EA3</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>05-P1DIMM7-12</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>6</sortorder>
                    <color>6C59DC</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>06-P2DIMM1-6</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>7</sortorder>
                    <color>AC8C14</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>07-P2DIMM7-12</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>8</sortorder>
                    <color>611F27</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>08-HDMax</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>9</sortorder>
                    <color>F230E0</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>09-ExpBayDrive</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>10</sortorder>
                    <color>5CCD18</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>10-Chipset</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>11</sortorder>
                    <color>BB2A02</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>11-PS1Inlet</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>12</sortorder>
                    <color>5A2B57</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>12-PS2Inlet</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>13</sortorder>
                    <color>89ABF8</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>13-VRP1</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>14</sortorder>
                    <color>7EC25C</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>14-VRP2</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>15</sortorder>
                    <color>274482</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>15-VRP1Mem</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>16</sortorder>
                    <color>2B5429</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>16-VRP1Mem</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>17</sortorder>
                    <color>8048B4</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>17-VRP2Mem</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>18</sortorder>
                    <color>FD5434</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>18-VRP2Mem</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>19</sortorder>
                    <color>790E1F</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>19-PS1Internal</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>20</sortorder>
                    <color>87AC4D</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>20-PS2Internal</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>21</sortorder>
                    <color>E89DF4</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>21-PCI1</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>22</sortorder>
                    <color>1A7C11</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>22-PCI2</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>23</sortorder>
                    <color>F63100</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>23-PCI3</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>24</sortorder>
                    <color>2774A4</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>24-PCI4</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>25</sortorder>
                    <color>A54F10</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>25-PCI5</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>26</sortorder>
                    <color>FC6EA3</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>26-PCI6</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>27</sortorder>
                    <color>6C59DC</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>27-HDController</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>28</sortorder>
                    <color>AC8C14</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>28-LOMCard</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>29</sortorder>
                    <color>611F27</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>29-LOM</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>30</sortorder>
                    <color>F230E0</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>30-FrontAmbient</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>31</sortorder>
                    <color>5CCD18</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>31-PCI1Zone</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>32</sortorder>
                    <color>BB2A02</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>32-PCI2Zone</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>33</sortorder>
                    <color>5A2B57</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>33-PCI3Zone</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>34</sortorder>
                    <color>89ABF8</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>34-PCI4Zone</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>35</sortorder>
                    <color>7EC25C</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>35-PCI5Zone</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>36</sortorder>
                    <color>274482</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>36-PCI6Zone</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>37</sortorder>
                    <color>2B5429</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>37-HDCntlrZone</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>38</sortorder>
                    <color>8048B4</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>38-IOZone</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>39</sortorder>
                    <color>FD5434</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>39-PS2Zone</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>40</sortorder>
                    <color>790E1F</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>40-BatteryZone</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>41</sortorder>
                    <color>87AC4D</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>41-iLOZone</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>42</sortorder>
                    <color>E89DF4</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>42-RearHDMax</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>43</sortorder>
                    <color>1A7C11</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>43-StorageBatt</key>
                    </item>
                </graph_item>
                <graph_item>
                    <sortorder>44</sortorder>
                    <color>F63100</color>
                    <item>
                        <host>IPMI_HPDL380G9</host>
                        <key>44-Fuse</key>
                    </item>
                </graph_item>
            </graph_items>
        </graph>
    </graphs>
    <value_maps>
        <value_map>
            <name>IPMI Availability Status States</name>
            <mappings>
                <mapping>
                    <value>1</value>
                    <newvalue>Device Removed / Device Absent</newvalue>
                </mapping>
                <mapping>
                    <value>2</value>
                    <newvalue>Device Inserted / Device Present</newvalue>
                </mapping>
            </mappings>
        </value_map>
        <value_map>
            <name>IPMI Battery</name>
            <mappings>
                <mapping>
                    <value>1</value>
                    <newvalue>Battery low (predictive failure)</newvalue>
                </mapping>
                <mapping>
                    <value>2</value>
                    <newvalue>Battery failed</newvalue>
                </mapping>
                <mapping>
                    <value>4</value>
                    <newvalue>Battery presence detected</newvalue>
                </mapping>
            </mappings>
        </value_map>
        <value_map>
            <name>IPMI Drive Slot (Bay)</name>
            <mappings>
                <mapping>
                    <value>1</value>
                    <newvalue>Drive Present</newvalue>
                </mapping>
                <mapping>
                    <value>2</value>
                    <newvalue>Drive Fault</newvalue>
                </mapping>
                <mapping>
                    <value>4</value>
                    <newvalue>Predictive Failure</newvalue>
                </mapping>
                <mapping>
                    <value>8</value>
                    <newvalue>Hot Spare</newvalue>
                </mapping>
                <mapping>
                    <value>16</value>
                    <newvalue>Consistency Check / Parity Check in progress</newvalue>
                </mapping>
                <mapping>
                    <value>32</value>
                    <newvalue>In Critical Array</newvalue>
                </mapping>
                <mapping>
                    <value>33</value>
                    <newvalue>Drive Present In Critical Array</newvalue>
                </mapping>
                <mapping>
                    <value>35</value>
                    <newvalue>Drive Fault In Critical Array</newvalue>
                </mapping>
                <mapping>
                    <value>64</value>
                    <newvalue>In Failed Array</newvalue>
                </mapping>
                <mapping>
                    <value>128</value>
                    <newvalue>Rebuild/Remap in progress</newvalue>
                </mapping>
                <mapping>
                    <value>256</value>
                    <newvalue>Rebuild/Remap Abortes (was not complete normally)</newvalue>
                </mapping>
            </mappings>
        </value_map>
        <value_map>
            <name>IPMI Memory</name>
            <mappings>
                <mapping>
                    <value>1</value>
                    <newvalue>Correctable ECC</newvalue>
                </mapping>
                <mapping>
                    <value>2</value>
                    <newvalue>Uncorrectable ECC</newvalue>
                </mapping>
                <mapping>
                    <value>4</value>
                    <newvalue>Parity</newvalue>
                </mapping>
                <mapping>
                    <value>8</value>
                    <newvalue>Memory Scrub Failed</newvalue>
                </mapping>
                <mapping>
                    <value>16</value>
                    <newvalue>Memory Device Disabled</newvalue>
                </mapping>
                <mapping>
                    <value>32</value>
                    <newvalue>Correctable ECC / other correctable memory error logging limit r</newvalue>
                </mapping>
                <mapping>
                    <value>64</value>
                    <newvalue>Presence detected</newvalue>
                </mapping>
                <mapping>
                    <value>128</value>
                    <newvalue>Configuration error</newvalue>
                </mapping>
                <mapping>
                    <value>256</value>
                    <newvalue>Spare</newvalue>
                </mapping>
                <mapping>
                    <value>512</value>
                    <newvalue>Memory Automatically Throttled</newvalue>
                </mapping>
                <mapping>
                    <value>1024</value>
                    <newvalue>Critical Overtemperature</newvalue>
                </mapping>
            </mappings>
        </value_map>
        <value_map>
            <name>IPMI OEM LED UID</name>
            <mappings>
                <mapping>
                    <value>1</value>
                    <newvalue>On</newvalue>
                </mapping>
                <mapping>
                    <value>2</value>
                    <newvalue>Off</newvalue>
                </mapping>
                <mapping>
                    <value>4</value>
                    <newvalue>Blink</newvalue>
                </mapping>
            </mappings>
        </value_map>
        <value_map>
            <name>IPMI Power Supply</name>
            <mappings>
                <mapping>
                    <value>0</value>
                    <newvalue>Power supply not installed</newvalue>
                </mapping>
                <mapping>
                    <value>1</value>
                    <newvalue>Presence detected</newvalue>
                </mapping>
                <mapping>
                    <value>2</value>
                    <newvalue>Failure detected</newvalue>
                </mapping>
                <mapping>
                    <value>4</value>
                    <newvalue>Predictive Failure</newvalue>
                </mapping>
                <mapping>
                    <value>8</value>
                    <newvalue>Input lost (AC/DC)</newvalue>
                </mapping>
                <mapping>
                    <value>16</value>
                    <newvalue>Input lost or out-of-range</newvalue>
                </mapping>
                <mapping>
                    <value>32</value>
                    <newvalue>Input out-of-range but present</newvalue>
                </mapping>
                <mapping>
                    <value>64</value>
                    <newvalue>Configuration error</newvalue>
                </mapping>
                <mapping>
                    <value>128</value>
                    <newvalue>Inactive</newvalue>
                </mapping>
            </mappings>
        </value_map>
        <value_map>
            <name>IPMI Redundancy States</name>
            <mappings>
                <mapping>
                    <value>1</value>
                    <newvalue>Fully Redundant</newvalue>
                </mapping>
                <mapping>
                    <value>2</value>
                    <newvalue>Redundancy Lost</newvalue>
                </mapping>
                <mapping>
                    <value>4</value>
                    <newvalue>Redundancy Degraded</newvalue>
                </mapping>
                <mapping>
                    <value>8</value>
                    <newvalue>Non-Redundant</newvalue>
                </mapping>
                <mapping>
                    <value>16</value>
                    <newvalue>Non-Redundant</newvalue>
                </mapping>
                <mapping>
                    <value>32</value>
                    <newvalue>Non-Redundant</newvalue>
                </mapping>
                <mapping>
                    <value>64</value>
                    <newvalue>Redundancy Degraded</newvalue>
                </mapping>
                <mapping>
                    <value>128</value>
                    <newvalue>Redundancy Degraded</newvalue>
                </mapping>
            </mappings>
        </value_map>
        <value_map>
            <name>IPMI Severity Event States</name>
            <mappings>
                <mapping>
                    <value>1</value>
                    <newvalue>Transition to OK</newvalue>
                </mapping>
                <mapping>
                    <value>2</value>
                    <newvalue>Transition to Non-Critical from OK</newvalue>
                </mapping>
                <mapping>
                    <value>4</value>
                    <newvalue>Transition to Critical from less severe</newvalue>
                </mapping>
                <mapping>
                    <value>8</value>
                    <newvalue>Transition to Non-recoverable from less severe</newvalue>
                </mapping>
                <mapping>
                    <value>16</value>
                    <newvalue>Transition to Non-Critical from more severe</newvalue>
                </mapping>
                <mapping>
                    <value>32</value>
                    <newvalue>Transition to Critical from Non-recoverable</newvalue>
                </mapping>
                <mapping>
                    <value>64</value>
                    <newvalue>Transition to Non-recoverable</newvalue>
                </mapping>
                <mapping>
                    <value>128</value>
                    <newvalue>Monitor</newvalue>
                </mapping>
                <mapping>
                    <value>256</value>
                    <newvalue>Informational</newvalue>
                </mapping>
            </mappings>
        </value_map>
    </value_maps>
</zabbix_export>
