5.0
2021-08-03T12:05:41Z
9 Templates Group
IPMI_HPDL560G10
IPMI_HPDL560G10
9 Templates Group
CPU
Drives
Fan
Health
LAN
Memory
Power
Temp
-
01-Inlet Ambient
IPMI
01-InletAmbient
300
30d
360d
FLOAT
°C
01-Inlet Ambient
Temp
{last()}>47
Critical Temp Inlet Ambient on {HOSTNAME} (HW)
HIGH
{last()}>42
Error Temp Inlet Ambient on {HOSTNAME} (HW)
AVERAGE
-
02-CPU 1
IPMI
02-CPU1
300
30d
360d
FLOAT
°C
02-CPU 1
CPU
Temp
-
03-CPU 2
IPMI
03-CPU2
300
30d
360d
FLOAT
°C
03-CPU 2
CPU
Temp
-
04-CPU 3
IPMI
04-CPU3
300
30d
360d
FLOAT
°C
04-CPU 3
CPU
Temp
-
05-CPU 4
IPMI
05-CPU4
300
30d
360d
FLOAT
°C
05-CPU 4
CPU
Temp
-
06-P1 DIMM 1-6
IPMI
06-P1DIMM1-6
300
30d
360d
FLOAT
°C
06-P1 DIMM 1-6
Memory
Temp
-
08-P1 DIMM 7-12
IPMI
08-P1DIMM7-12
300
30d
360d
FLOAT
°C
08-P1 DIMM 7-12
Memory
Temp
-
10-P2 DIMM 1-6
IPMI
10-P2DIMM1-6
300;50/1-7,00:00-24:00
30d
360d
FLOAT
°C
10-P2 DIMM 1-6
Memory
Temp
-
12-P2 DIMM 7-12
IPMI
12-P2DIMM7-12
300
30d
360d
FLOAT
°C
12-P2 DIMM 7-12
Memory
Temp
-
14-P3 DIMM 1-6
IPMI
14-P3DIMM1-6
300;50/1-7,00:00-24:00
30d
360d
FLOAT
°C
14-P3 DIMM 1-6
Memory
Temp
-
16-P3 DIMM 7-12
IPMI
16-P3DIMM7-12
300
30d
360d
FLOAT
°C
16-P3 DIMM 7-12
Memory
Temp
-
18-P4 DIMM 1-6
IPMI
18-P4DIMM1-6
300;50/1-7,00:00-24:00
30d
360d
FLOAT
°C
18-P4 DIMM 1-6
Memory
Temp
-
20-P4 DIMM 7-12
IPMI
20-P4DIMM7-12
300
30d
360d
FLOAT
°C
20-P4 DIMM 7-12
Memory
Temp
-
22-HD Max
IPMI
22-HDMax
300
30d
360d
FLOAT
°C
22-HD Max
Temp
{last()}>60
Error Temp HD Max on {HOSTNAME} (HW)
AVERAGE
-
23-Exp Bay Drive
IPMI
23-ExpBayDrive
300
30d
360d
FLOAT
°C
23-Exp Bay Drive
Temp
{last()}>60
Error Temp Exp Bay Drive on {HOSTNAME} (HW)
AVERAGE
-
24-Stor Batt 1
IPMI
24-StorBatt1
300
30d
360d
FLOAT
°C
24-Stor Batt 1
Temp
-
25-Stor Batt 2
IPMI
25-StorBatt2
300
30d
360d
FLOAT
°C
25-Stor Batt 2
Temp
-
26-VR P1
IPMI
26-VRP1
300
30d
360d
FLOAT
°C
26-VR P1
Temp
-
27-VR P2
IPMI
27-VRP2
300
30d
360d
FLOAT
°C
27-VR P2
Temp
-
28-VR P3
IPMI
28-VRP3
300
30d
360d
FLOAT
°C
28-VR P3
Temp
-
29-VR P4
IPMI
29-VRP4
300
30d
360d
FLOAT
°C
29-VR P4
Temp
-
30-VR P1 Mem 1
IPMI
30-VRP1Mem1
300
30d
360d
FLOAT
°C
30-VR P1 Mem 1
Temp
-
31-VR P1 Mem 2
IPMI
31-VRP1Mem2
300
30d
360d
FLOAT
°C
31-VR P1 Mem 2
Temp
-
32-VR P2 Mem 1
IPMI
32-VRP2Mem1
300
30d
360d
FLOAT
°C
32-VR P2 Mem 1
Temp
-
33-VR P2 Mem 2
IPMI
33-VRP2Mem2
300
30d
360d
FLOAT
°C
33-VR P2 Mem 2
Temp
-
34-VR P3 Mem 1
IPMI
34-VRP3Mem1
300
30d
360d
FLOAT
°C
34-VR P3 Mem 1
Temp
-
35-VR P3 Mem 2
IPMI
35-VRP3Mem2
300
30d
360d
FLOAT
°C
35-VR P3 Mem 2
Temp
-
36-VR P4 Mem 1
IPMI
36-VRP4Mem1
300
30d
360d
FLOAT
°C
36-VR P4 Mem 1
Temp
-
37-VR P4 Mem 2
IPMI
37-VRP4Mem2
300
30d
360d
FLOAT
°C
37-VR P4 Mem 2
Temp
-
38-Front Ambient
IPMI
38-FrontAmbient
300
30d
360d
FLOAT
°C
38-Front Ambient
Temp
{last()}>60
Error Temp Front Ambient on {HOSTNAME} (HW)
AVERAGE
-
40-Chipset
IPMI
40-Chipset
300
30d
360d
FLOAT
°C
40-Chipset
Temp
{last()}>100
Error Temp Chipset on {HOSTNAME} (HW)
AVERAGE
-
41-BMC
IPMI
41-BMC
300
30d
360d
FLOAT
°C
41-BMC
Temp
{last()}>115
Critical Temp BMC on {HOSTNAME} (HW)
HIGH
{last()}>110
Error Temp BMC on {HOSTNAME} (HW)
AVERAGE
-
42-BMC Zone
IPMI
42-BMCZone
300
30d
360d
FLOAT
°C
42-BMC Zone
Temp
{last()}>95
Critical Temp BMC Zone on {HOSTNAME} (HW)
HIGH
{last()}>90
Error Temp BMC Zone on {HOSTNAME} (HW)
AVERAGE
-
43-HD Controller
IPMI
43-HDController
300
30d
360d
FLOAT
°C
43-HD Controller
Temp
{last()}>100
Error Temp HD Controller on {HOSTNAME} (HW)
AVERAGE
-
44-HD Cntlr Zone
IPMI
44-HDCntlrZone
300
30d
360d
FLOAT
°C
44-HD Cntlr Zone
Temp
{last()}>90
Critical Temp HD Cntlr Zone on {HOSTNAME} (HW)
HIGH
{last()}>85
Error Temp HD Cntlr Zone on {HOSTNAME} (HW)
AVERAGE
-
45-LOM Card
IPMI
45-LOMCard
300
30d
360d
FLOAT
°C
45-LOM Card
Temp
{last()}>100
Error Temp LOM Card on {HOSTNAME} (HW)
AVERAGE
-
46-I/O Zone
IPMI
46-IOZone
300
30d
360d
FLOAT
°C
46-I/O Zone
Temp
{last()}>95
Critical Temp I/O Zone on {HOSTNAME} (HW)
HIGH
{last()}>90
Error Temp I/O Zone on {HOSTNAME} (HW)
AVERAGE
-
47-PCI 1
IPMI
47-PCI1
300
30d
360d
FLOAT
°C
47-PCI 1
Temp
-
48-PCI 1 Zone
IPMI
48-PCI1Zone
300
30d
360d
FLOAT
°C
48-PCI 1 Zone
Temp
-
49-PCI 2
IPMI
49-PCI2
300
30d
360d
FLOAT
°C
49-PCI 2
Temp
-
50-PCI 2 Zone
IPMI
50-PCI2Zone
300
30d
360d
FLOAT
°C
50-PCI 2 Zone
Temp
-
51-PCI 3
IPMI
51-PCI3
300
30d
360d
FLOAT
°C
51-PCI 3
Temp
-
52-PCI 3 Zone
IPMI
52-PCI3Zone
300
30d
360d
FLOAT
°C
52-PCI 3 Zone
Temp
-
53-PCI 4
IPMI
53-PCI4
300
30d
360d
FLOAT
°C
53-PCI 4
Temp
-
54-PCI 4 Zone
IPMI
54-PCI4Zone
300
30d
360d
FLOAT
°C
54-PCI 4 Zone
Temp
-
55-PCI 5
IPMI
55-PCI5
300
30d
360d
FLOAT
°C
55-PCI 5
Temp
-
56-PCI 5 Zone
IPMI
56-PCI5Zone
300
30d
360d
FLOAT
°C
56-PCI 5 Zone
Temp
-
57-PCI 6
IPMI
57-PCI6
300
30d
360d
FLOAT
°C
57-PCI 6
Temp
-
58-PCI 6 Zone
IPMI
58-PCI6Zone
300
30d
360d
FLOAT
°C
58-PCI 6 Zone
Temp
-
59-PCI 7
IPMI
59-PCI7
300
30d
360d
FLOAT
°C
59-PCI 7
Temp
-
60-PCI 7 Zone
IPMI
60-PCI7Zone
300
30d
360d
FLOAT
°C
60-PCI 7 Zone
Temp
-
61-PCI 8
IPMI
61-PCI8
300
30d
360d
FLOAT
°C
61-PCI 8
Temp
-
62-PCI 8 Zone
IPMI
62-PCI8Zone
300
30d
360d
FLOAT
°C
62-PCI 8 Zone
Temp
-
63-Battery Zone
IPMI
63-BatteryZone
300
30d
360d
FLOAT
°C
63-Battery Zone
Temp
{last()}>80
Critical Temp Battery Zone on {HOSTNAME} (HW)
HIGH
{last()}>75
Error Temp Battery Zone on {HOSTNAME} (HW)
AVERAGE
-
64-P/S 1 Inlet
IPMI
64-PS1Inlet
300
30d
360d
FLOAT
°C
64-P/S 1 Inlet
Temp
-
65-P/S 2 Inlet
IPMI
65-PS2Inlet
300
30d
360d
FLOAT
°C
65-P/S 2 Inlet
Temp
-
66-P/S 3 Inlet
IPMI
66-PS3Inlet
300
30d
360d
FLOAT
°C
66-P/S 3 Inlet
Temp
-
67-P/S 4 Inlet
IPMI
67-PS4Inlet
300
30d
360d
FLOAT
°C
67-P/S 4 Inlet
Temp
-
68-P/S 1
IPMI
68-PS1
300
30d
360d
FLOAT
°C
68-P/S 1
Temp
-
69-P/S 2
IPMI
69-PS2
300
30d
360d
FLOAT
°C
69-P/S 2
Temp
-
70-P/S 3
IPMI
70-PS3
300
30d
360d
FLOAT
°C
70-P/S 3
Temp
-
71-P/S 4
IPMI
71-PS4
300
30d
360d
FLOAT
°C
71-P/S 4
Temp
-
72-P/S 2 Zone
IPMI
72-PS2Zone
300
30d
360d
FLOAT
°C
72-P/S 2 Zone
Temp
{last()}>80
Critical Temp P/S 2 Zone on {HOSTNAME} (HW)
HIGH
{last()}>75
Error Temp P/S 2 Zone on {HOSTNAME} (HW)
AVERAGE
-
73-E-Fuse
IPMI
73-EFuse
300
30d
360d
FLOAT
°C
73-E-Fuse
Temp
{last()}>100
Error Temp E-Fuse on {HOSTNAME} (HW)
AVERAGE
-
108-PCI 1 M2
IPMI
108-PCI1M2
300
30d
360d
FLOAT
°C
108-PCI 1 M2
Temp
-
109-PCI 1 M2 Zn
IPMI
109-PCI1M2Zn
300
30d
360d
FLOAT
°C
109-PCI 1 M2 Zn
Temp
-
110-PCI 2 M2
IPMI
110-PCI2M2
300
30d
360d
FLOAT
°C
110-PCI 2 M2
Temp
-
111-PCI 2 M2 Zn
IPMI
111-PCI2M2Zn
300
30d
360d
FLOAT
°C
111-PCI 2 M2 Zn
Temp
-
112-PCI 3 M2
IPMI
112-PCI3M2
300
30d
360d
FLOAT
°C
112-PCI 3 M2
Temp
-
113-PCI 3 M2 Zn
IPMI
113-PCI3M2Zn
300
30d
360d
FLOAT
°C
113-PCI 3 M2 Zn
Temp
-
114-PCI 4 M2
IPMI
114-PCI4M2
300
30d
360d
FLOAT
°C
114-PCI 4 M2
Temp
-
115-PCI 4 M2 Zn
IPMI
115-PCI4M2Zn
300
30d
360d
FLOAT
°C
115-PCI 4 M2 Zn
Temp
-
116-PCI 5 M2
IPMI
116-PCI5M2
300
30d
360d
FLOAT
°C
116-PCI 5 M2
Temp
-
117-PCI 5 M2 Zn
IPMI
117-PCI5M2Zn
300
30d
360d
FLOAT
°C
117-PCI 5 M2 Zn
Temp
-
118-PCI 6 M2
IPMI
118-PCI6M2
300
30d
360d
FLOAT
°C
118-PCI 6 M2
Temp
-
119-PCI 6 M2 Zn
IPMI
119-PCI6M2Zn
300
30d
360d
FLOAT
°C
119-PCI 6 M2 Zn
Temp
-
120-PCI 7 M2
IPMI
120-PCI7M2
300
30d
360d
FLOAT
°C
120-PCI 7 M2
Temp
-
121-PCI 7 M2 Zn
IPMI
121-PCI7M2Zn
300
30d
360d
FLOAT
°C
121-PCI 7 M2 Zn
Temp
-
122-PCI 8 M2
IPMI
122-PCI8M2
300
30d
360d
FLOAT
°C
122-PCI 8 M2
Temp
-
123-PCI 8 M2 Zn
IPMI
123-PCI8M2Zn
300
30d
360d
FLOAT
°C
123-PCI 8 M2 Zn
Temp
-
ALOM_Link_P1
IPMI
ALOMLinkP1
300
30d
180d
ALOM_Link_P1
LAN
IPMI LAN
-
ALOM_Link_P2
IPMI
ALOMLinkP2
300
30d
180d
ALOM_Link_P2
LAN
IPMI LAN
-
ALOM_Link_P3
IPMI
ALOMLinkP3
300
30d
180d
ALOM_Link_P3
LAN
IPMI LAN
-
ALOM_Link_P4
IPMI
ALOMLinkP4
300
30d
180d
ALOM_Link_P4
LAN
IPMI LAN
-
CPU_Stat_C1
IPMI
CPUStatC1
600
30d
180d
CPU_Stat_C1
CPU
IPMI Processor
-
CPU_Stat_C2
IPMI
CPUStatC2
600
30d
180d
CPU_Stat_C2
CPU
IPMI Processor
-
CPU_Stat_C3
IPMI
CPUStatC3
600
30d
180d
CPU_Stat_C3
CPU
IPMI Processor
-
CPU_Stat_C4
IPMI
CPUStatC4
600
30d
180d
CPU_Stat_C4
CPU
IPMI Processor
-
CPU Utilization
IPMI
CPUUtilization
60
30d
360d
FLOAT
%
CPU Utilization
CPU
-
Dr_Stat_1I3_B001
IPMI
Dr_Stat_1I3_B001
300
30d
180d
Dr_Stat_1I3_B001
Drives
IPMI Drive Slot (Bay)
{last()}>1
Predictive failure Drive 1 on {HOSTNAME} (HW)
AVERAGE
-
Dr_Stat_1I3_B002
IPMI
Dr_Stat_1I3_B002
300
30d
180d
Dr_Stat_1I3_B002
Drives
IPMI Drive Slot (Bay)
{last()}>1
Predictive failure Drive 2 on {HOSTNAME} (HW)
AVERAGE
-
Dr_Stat_1I3_B003
IPMI
Dr_Stat_1I3_B003
300
30d
180d
Dr_Stat_1I3_B003
Drives
IPMI Drive Slot (Bay)
{last()}>1
Predictive failure Drive 3 on {HOSTNAME} (HW)
AVERAGE
-
Dr_Stat_1I3_B004
IPMI
Dr_Stat_1I3_B004
300
30d
180d
Dr_Stat_1I3_B004
Drives
IPMI Drive Slot (Bay)
{last()}>1
Predictive failure Drive 4 on {HOSTNAME} (HW)
AVERAGE
-
Dr_Stat_2I3_B005
IPMI
Dr_Stat_2I3_B005
300
30d
180d
Dr_Stat_2I3_B005
Drives
IPMI Drive Slot (Bay)
{last()}>1
Predictive failure Drive 5 on {HOSTNAME} (HW)
AVERAGE
-
Dr_Stat_2I3_B006
IPMI
Dr_Stat_2I3_B006
300
30d
180d
Dr_Stat_2I3_B006
Drives
IPMI Drive Slot (Bay)
{last()}>1
Predictive failure Drive 6 on {HOSTNAME} (HW)
AVERAGE
-
Dr_Stat_2I3_B007
IPMI
Dr_Stat_2I3_B007
300
30d
180d
Dr_Stat_2I3_B007
Drives
IPMI Drive Slot (Bay)
{last()}>1
Predictive failure Drive 7 on {HOSTNAME} (HW)
AVERAGE
-
Dr_Stat_2I3_B008
IPMI
Dr_Stat_2I3_B008
300
30d
180d
Dr_Stat_2I3_B008
Drives
IPMI Drive Slot (Bay)
{last()}>1
Predictive failure Drive 8 on {HOSTNAME} (HW)
AVERAGE
-
Fan 1
IPMI
Fan1
300
30d
180d
Fan 1
Fan
IPMI Severity Event States
-
Fan 1 DutyCycle
IPMI
Fan1DutyCycle
300
30d
180d
FLOAT
% Speed
Fan 1 DutyCycle
Fan
-
Fan 1 Presence
IPMI
Fan1Presence
600
30d
180d
Fan 1 Presence
Fan
IPMI Availability Status States
-
Fan 2
IPMI
Fan2
300
30d
180d
FLOAT
Fan 2
Fan
IPMI Severity Event States
-
Fan 2 DutyCycle
IPMI
Fan2DutyCycle
300
30d
180d
FLOAT
% Speed
Fan 2 DutyCycle
Fan
-
Fan 2 Presence
IPMI
Fan2Presence
600
30d
180d
Fan 2 Presence
Fan
IPMI Availability Status States
-
Fan 3
IPMI
Fan3
300
30d
180d
FLOAT
Fan 3
Fan
IPMI Severity Event States
-
Fan 3 DutyCycle
IPMI
Fan3DutyCycle
300
30d
180d
FLOAT
% Speed
Fan 3 DutyCycle
Fan
-
Fan 3 Presence
IPMI
Fan3Presence
600
30d
180d
Fan 3 Presence
Fan
IPMI Availability Status States
-
Fan 4
IPMI
Fan4
300
30d
180d
FLOAT
Fan 4
Fan
IPMI Severity Event States
-
Fan 4 DutyCycle
IPMI
Fan4DutyCycle
300
30d
180d
FLOAT
% Speed
Fan 4 DutyCycle
Fan
-
Fan 4 Presence
IPMI
Fan4Presence
600
30d
180d
Fan 4 Presence
Fan
IPMI Availability Status States
-
Fan 5
IPMI
Fan5
300
30d
180d
FLOAT
Fan 5
Fan
IPMI Severity Event States
-
Fan 5 DutyCycle
IPMI
Fan5DutyCycle
300
30d
180d
FLOAT
% Speed
Fan 5 DutyCycle
Fan
-
Fan 5 Presence
IPMI
Fan5Presence
600
30d
180d
Fan 5 Presence
Fan
IPMI Availability Status States
-
Fan 6
IPMI
Fan6
300
30d
180d
FLOAT
Fan 6
Fan
IPMI Severity Event States
-
Fan 6 DutyCycle
IPMI
Fan6DutyCycle
300
30d
180d
FLOAT
% Speed
Fan 6 DutyCycle
Fan
-
Fan 6 Presence
IPMI
Fan6Presence
600
30d
180d
Fan 6 Presence
Fan
IPMI Availability Status States
-
Fan 7
IPMI
Fan7
300
30d
180d
FLOAT
Fan 7
Fan
IPMI Severity Event States
-
Fan 7 DutyCycle
IPMI
Fan7DutyCycle
300
30d
180d
FLOAT
% Speed
Fan 7 DutyCycle
Fan
-
Fan 7 Presence
IPMI
Fan7Presence
600
30d
180d
Fan 7 Presence
Fan
IPMI Availability Status States
-
Fans
IPMI
Fans
90
30d
180d
Fans
Fan
Health
IPMI Redundancy States
-
Intrusion
IPMI
Intrusion
600
30d
180d
Intrusion
Health
IPMI Physical Security (Chassis Intrusion)
-
Megacell Status1
IPMI
MegacellStatus1
300
30d
180d
Megacell Status1
Health
Power
IPMI Battery
-
Megacell Status2
IPMI
MegacellStatus2
300
30d
180d
Megacell Status2
Health
Power
IPMI Battery
-
Memory Status
IPMI
MemoryStatus
300
30d
180d
Memory Status
Health
Memory
IPMI Memory
{last()}<>64
Memory status changed - need check on {HOSTNAME}
WARNING
-
Power Meter
IPMI
PowerMeter
300
30d
180d
FLOAT
Watts
Power Meter
Power
-
Power Supplies
IPMI
PowerSupplies
120
30d
180d
FLOAT
Power Supplies
Power
IPMI Redundancy States
{last()}<>1
Power Supplies not fully redundant on {HOSTNAME} (HW)
HIGH
-
Power Supply 1
IPMI
PowerSupply1
90
30d
180d
Power Supply 1
Power
IPMI Power Supply
-
Power Supply 2
IPMI
PowerSupply2
90
30d
180d
Power Supply 2
Power
IPMI Power Supply
-
Power Supply 3
IPMI
PowerSupply3
90
30d
180d
Power Supply 3
Power
IPMI Power Supply
-
Power Supply 4
IPMI
PowerSupply4
90
30d
180d
Power Supply 4
Power
IPMI Power Supply
-
PS 1 Output
IPMI
PS1Output
300
30d
180d
FLOAT
Watts
PS 1 Output
Power
-
PS 2 Output
IPMI
PS2Output
300
30d
180d
FLOAT
Watts
PS 2 Output
Power
-
PS 3 Output
IPMI
PS3Output
300
30d
180d
FLOAT
Watts
PS 3 Output
Power
-
PS 4 Output
IPMI
PS4Output
300
30d
180d
FLOAT
Watts
PS 4 Output
Power
-
SysHealth_Stat
IPMI
SysHealthStat
90
30d
180d
SysHealth_Stat
Health
IPMI Severity Event States
{last()}<>1 or {nodata(600)}=1
Error SysHealth_Stat on {HOSTNAME} (HW)
HIGH
-
UID
IPMI
UID
90
30d
180d
UID
Health
IPMI OEM LED UID
{IPMI_HPDL560G10:MegacellStatus1.last()}<>4 or {IPMI_HPDL560G10:MegacellStatus2.last()}<>4
Check Battery {HOSTNAME} (HW)
AVERAGE
{IPMI_HPDL560G10:48-PCI1Zone.last()}>95 or
{IPMI_HPDL560G10:50-PCI2Zone.last()}>95 or
{IPMI_HPDL560G10:52-PCI3Zone.last()}>95 or
{IPMI_HPDL560G10:54-PCI4Zone.last()}>95 or
{IPMI_HPDL560G10:56-PCI5Zone.last()}>95 or
{IPMI_HPDL560G10:58-PCI6Zone.last()}>95 or
{IPMI_HPDL560G10:60-PCI7Zone.last()}>95 or
{IPMI_HPDL560G10:62-PCI8Zone.last()}>95
Critical Temp PCI Zone on {HOSTNAME} (HW)
HIGH
{IPMI_HPDL560G10:26-VRP1.last()}>120 or
{IPMI_HPDL560G10:27-VRP2.last()}>120 or
{IPMI_HPDL560G10:28-VRP3.last()}>120 or
{IPMI_HPDL560G10:29-VRP4.last()}>120 or
{IPMI_HPDL560G10:30-VRP1Mem1.last()}>120 or
{IPMI_HPDL560G10:31-VRP1Mem2.last()}>120 or
{IPMI_HPDL560G10:32-VRP2Mem1.last()}>120 or
{IPMI_HPDL560G10:33-VRP2Mem2.last()}>120 or
{IPMI_HPDL560G10:34-VRP3Mem1.last()}>120 or
{IPMI_HPDL560G10:35-VRP3Mem2.last()}>120 or
{IPMI_HPDL560G10:36-VRP4Mem1.last()}>120 or
{IPMI_HPDL560G10:37-VRP4Mem2.last()}>120
Critical Temp VR P on {HOSTNAME} (HW)
HIGH
{IPMI_HPDL560G10:PowerSupply1.last()}=0 or {IPMI_HPDL560G10:PowerSupply2.last()}=0 or {IPMI_HPDL560G10:PowerSupply3.last()}=0 or {IPMI_HPDL560G10:PowerSupply4.last()}=0
Empty Power Supply on {HOSTNAME} (HW)
AVERAGE
({IPMI_HPDL560G10:CPUStatC1.last()}<>128 and {IPMI_HPDL560G10:CPUStatC1.last()}<>0) or ({IPMI_HPDL560G10:CPUStatC2.last()}<>128 and {IPMI_HPDL560G10:CPUStatC2.last()}<>0) or ({IPMI_HPDL560G10:CPUStatC3.last()}<>128 and {IPMI_HPDL560G10:CPUStatC3.last()}<>0) or ({IPMI_HPDL560G10:CPUStatC4.last()}<>128 and {IPMI_HPDL560G10:CPUStatC4.last()}<>0)
Error CPU on {HOSTNAME} (HW)
HIGH
{IPMI_HPDL560G10:Fan1.last()}<>1 or {IPMI_HPDL560G10:Fan2.last()}<>1 or {IPMI_HPDL560G10:Fan3.last()}<>1 or {IPMI_HPDL560G10:Fan4.last()}<>1 or {IPMI_HPDL560G10:Fan5.last()}<>1 or {IPMI_HPDL560G10:Fan6.last()}<>1 or
{IPMI_HPDL560G10:Fan7.last()}<>1 or {IPMI_HPDL560G10:Fans.last()}<>1
Error FANS on {HOSTNAME}
AVERAGE
{IPMI_HPDL560G10:PowerSupply1.last()}>1 or {IPMI_HPDL560G10:PowerSupply2.last()}>1 or {IPMI_HPDL560G10:PowerSupply3.last()}>1 or {IPMI_HPDL560G10:PowerSupply4.last()}>1
Error Power Supply on {HOSTNAME} (HW)
HIGH
{IPMI_HPDL560G10:02-CPU1.last()}>70 or {IPMI_HPDL560G10:03-CPU2.last()}>70 or {IPMI_HPDL560G10:04-CPU3.last()}>70 or {IPMI_HPDL560G10:05-CPU4.last()}>70
Error Temp CPU on {HOSTNAME} (HW)
AVERAGE
{IPMI_HPDL560G10:06-P1DIMM1-6.last()}>90 or
{IPMI_HPDL560G10:08-P1DIMM7-12.last()}>90 or
{IPMI_HPDL560G10:10-P2DIMM1-6.last()}>90 or
{IPMI_HPDL560G10:12-P2DIMM7-12.last()}>90 or
{IPMI_HPDL560G10:14-P3DIMM1-6.last()}>90 or
{IPMI_HPDL560G10:16-P3DIMM7-12.last()}>90 or
{IPMI_HPDL560G10:18-P4DIMM1-6.last()}>90 or
{IPMI_HPDL560G10:20-P4DIMM7-12.last()}>90
Error Temp DIMM on {HOSTNAME} (HW)
AVERAGE
{IPMI_HPDL560G10:108-PCI1M2.last()}>80 or
{IPMI_HPDL560G10:110-PCI2M2.last()}>80 or
{IPMI_HPDL560G10:112-PCI3M2.last()}>80 or
{IPMI_HPDL560G10:114-PCI4M2.last()}>80 or
{IPMI_HPDL560G10:116-PCI5M2.last()}>80 or
{IPMI_HPDL560G10:118-PCI6M2.last()}>80 or
{IPMI_HPDL560G10:120-PCI7M2.last()}>80 or
{IPMI_HPDL560G10:122-PCI8M2.last()}>80
Error Temp PCI M2 on {HOSTNAME} (HW)
AVERAGE
{IPMI_HPDL560G10:47-PCI1.last()}>100 or
{IPMI_HPDL560G10:49-PCI2.last()}>100 or
{IPMI_HPDL560G10:51-PCI3.last()}>100 or
{IPMI_HPDL560G10:53-PCI4.last()}>100 or
{IPMI_HPDL560G10:55-PCI5.last()}>100 or
{IPMI_HPDL560G10:57-PCI6.last()}>100 or
{IPMI_HPDL560G10:59-PCI7.last()}>100 or
{IPMI_HPDL560G10:61-PCI8.last()}>100
Error Temp PCI on {HOSTNAME} (HW)
AVERAGE
{IPMI_HPDL560G10:48-PCI1Zone.last()}>90 or
{IPMI_HPDL560G10:50-PCI2Zone.last()}>90 or
{IPMI_HPDL560G10:52-PCI3Zone.last()}>90 or
{IPMI_HPDL560G10:54-PCI4Zone.last()}>90 or
{IPMI_HPDL560G10:56-PCI5Zone.last()}>90 or
{IPMI_HPDL560G10:58-PCI6Zone.last()}>90 or
{IPMI_HPDL560G10:60-PCI7Zone.last()}>90 or
{IPMI_HPDL560G10:62-PCI8Zone.last()}>90
Error Temp PCI Zone on {HOSTNAME} (HW)
AVERAGE
{IPMI_HPDL560G10:24-StorBatt1.last()}>60 or {IPMI_HPDL560G10:25-StorBatt2.last()}>60
Error Temp Stor Batt 1 on {HOSTNAME} (HW)
AVERAGE
{IPMI_HPDL560G10:26-VRP1.last()}>115 or
{IPMI_HPDL560G10:27-VRP2.last()}>115 or
{IPMI_HPDL560G10:28-VRP3.last()}>115 or
{IPMI_HPDL560G10:29-VRP4.last()}>115 or
{IPMI_HPDL560G10:30-VRP1Mem1.last()}>115 or
{IPMI_HPDL560G10:31-VRP1Mem2.last()}>115 or
{IPMI_HPDL560G10:32-VRP2Mem1.last()}>115 or
{IPMI_HPDL560G10:33-VRP2Mem2.last()}>115 or
{IPMI_HPDL560G10:34-VRP3Mem1.last()}>115 or
{IPMI_HPDL560G10:35-VRP3Mem2.last()}>115 or
{IPMI_HPDL560G10:36-VRP4Mem1.last()}>115 or
{IPMI_HPDL560G10:37-VRP4Mem2.last()}>115
Error Temp VR P on {HOSTNAME} (HW)
AVERAGE
CPU Utilization
1
1A7C11
-
IPMI_HPDL560G10
CPUUtilization
Fan Speed
1A7C11
-
IPMI_HPDL560G10
Fan1DutyCycle
1
F63100
-
IPMI_HPDL560G10
Fan2DutyCycle
2
2774A4
-
IPMI_HPDL560G10
Fan3DutyCycle
3
A54F10
-
IPMI_HPDL560G10
Fan4DutyCycle
4
FC6EA3
-
IPMI_HPDL560G10
Fan5DutyCycle
5
6C59DC
-
IPMI_HPDL560G10
Fan6DutyCycle
6
AC8C14
-
IPMI_HPDL560G10
Fan7DutyCycle
Power
1A7C11
-
IPMI_HPDL560G10
PowerMeter
1
2774A4
-
IPMI_HPDL560G10
PS1Output
2
A54F10
-
IPMI_HPDL560G10
PS2Output
3
A54F10
-
IPMI_HPDL560G10
PS3Output
4
A54F10
-
IPMI_HPDL560G10
PS4Output
Temperature
0000EE
-
IPMI_HPDL560G10
02-CPU1
1
00C800
-
IPMI_HPDL560G10
03-CPU2
2
2774A4
-
IPMI_HPDL560G10
01-InletAmbient
3
A54F10
-
IPMI_HPDL560G10
06-P1DIMM1-6
4
FC6EA3
-
IPMI_HPDL560G10
08-P1DIMM7-12
5
6C59DC
-
IPMI_HPDL560G10
10-P2DIMM1-6
6
AC8C14
-
IPMI_HPDL560G10
12-P2DIMM7-12
7
611F27
-
IPMI_HPDL560G10
24-StorBatt1
8
F230E0
-
IPMI_HPDL560G10
38-FrontAmbient
9
5CCD18
-
IPMI_HPDL560G10
40-Chipset
10
BB2A02
-
IPMI_HPDL560G10
64-PS1Inlet
11
5A2B57
-
IPMI_HPDL560G10
65-PS2Inlet
12
89ABF8
-
IPMI_HPDL560G10
41-BMC
13
7EC25C
-
IPMI_HPDL560G10
68-PS1
14
274482
-
IPMI_HPDL560G10
69-PS2
15
2B5429
-
IPMI_HPDL560G10
73-EFuse
16
8048B4
-
IPMI_HPDL560G10
72-PS2Zone
17
00C800
-
IPMI_HPDL560G10
04-CPU3
18
00C800
-
IPMI_HPDL560G10
05-CPU4
19
A54F10
-
IPMI_HPDL560G10
14-P3DIMM1-6
20
FC6EA3
-
IPMI_HPDL560G10
16-P3DIMM7-12
21
A54F10
-
IPMI_HPDL560G10
18-P4DIMM1-6
22
FC6EA3
-
IPMI_HPDL560G10
20-P4DIMM7-12
IPMI Availability Status States
1
Device Removed / Device Absent
2
Device Inserted / Device Present
IPMI Battery
1
Battery low (predictive failure)
2
Battery failed
4
Battery presence detected
IPMI Drive Slot (Bay)
1
Drive Present
2
Drive Fault
4
Predictive Failure
8
Hot Spare
16
Consistency Check / Parity Check in progress
32
In Critical Array
33
Drive Present In Critical Array
35
Drive Fault In Critical Array
64
In Failed Array
128
Rebuild/Remap in progress
256
Rebuild/Remap Abortes (was not complete normally)
IPMI LAN
1
LAN Heartbeat Lost
2
LAN Heartbeat
IPMI Memory
1
Correctable ECC
2
Uncorrectable ECC
4
Parity
8
Memory Scrub Failed
16
Memory Device Disabled
32
Correctable ECC / other correctable memory error logging limit r
64
Presence detected
128
Configuration error
256
Spare
512
Memory Automatically Throttled
1024
Critical Overtemperature
IPMI OEM LED UID
1
On
2
Off
4
Blink
IPMI Physical Security (Chassis Intrusion)
0
OK
1
General Chassis Intrusion
2
Drive Bay intrusion
4
I/O Card area intrusion
8
Processor area intrusion
16
LAN Leash Lost
32
Unauthorized dock
64
FAN area intrusion
IPMI Power Supply
0
Power supply not installed
1
Presence detected
2
Failure detected
4
Predictive Failure
8
Input lost (AC/DC)
16
Input lost or out-of-range
32
Input out-of-range but present
64
Configuration error
128
Inactive
IPMI Processor
0
Processor not installed
1
IERR
2
Thermal Trip
4
FRB1/BIST failure
8
FRB2/Hang in POST failure
16
FRB3/Processor Startup/Initialization failure
32
Configuration Error
64
SM BIOS Uncorrectable CPU-complex Error
128
Processor Presence detected
256
Processor disabled
512
Terminator Presence Detected
1024
Processor Automatically Throttled
2048
Machine Check Exception Uncorrectable
4096
Correctable Machine Check Error
IPMI Redundancy States
1
Fully Redundant
2
Redundancy Lost
4
Redundancy Degraded
8
Non-Redundant
16
Non-Redundant
32
Non-Redundant
64
Redundancy Degraded
128
Redundancy Degraded
IPMI Severity Event States
1
Transition to OK
2
Transition to Non-Critical from OK
4
Transition to Critical from less severe
8
Transition to Non-recoverable from less severe
16
Transition to Non-Critical from more severe
32
Transition to Critical from Non-recoverable
64
Transition to Non-recoverable
128
Monitor
256
Informational