3.4
2018-10-08T09:19:38Z
PDU
APC Rack PDU
APC Rack PDU
PDU
SNMP traps
-
трап
17
snmptrap.fallback
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
1. SEVERE:Communication to the UPS has been lost. Steps to reestablish communication are in progress.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.1\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
2. SEVERE:The UPS has sensed a load greater than 100 percent of its rated capacity.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.2\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
3. SEVERE:The UPS failed its internal diagnostic self-test.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.3\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
4. SEVERE:The UPS batteries are discharged;if utility power fails an immediate low battery condition will exist. Sufficient runtime for necessary action cannot be guaranteed.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.4\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
5. WARNING:The UPS has switched to battery backup power.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.5\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
6. WARNING:The UPS has enabled SmartBoost(TM).
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.6\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
7. SEVERE:The UPS batteries are low and will soon be exhausted. If utility power is not restored the UPS will put itself to 'sleep' and immediately cut power to the load.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.7\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
8. INFORMATIONAL:Communication with the UPS has been established.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.8\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
9. INFORMATIONAL:Utility power has been restored.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.9\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
10. INFORMATIONAL:The UPS passed its internal self-test.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.10\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
11. INFORMATIONAL:The UPS has returned from a low battery condition.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.11\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
12. WARNING:The UPS has been turned 'off' by the management station.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.12\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
13. WARNING:The UPS is entering 'sleep' mode. Power to the load will be cut off.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.13\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
14. INFORMATION:The UPS has returned from 'sleep' mode. Power to the load has been restored.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.14\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
15. WARNING:The UPS has started its reboot sequence. The UPS will reboot itself at this time.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.15\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
16. WARNING:The dip switch settings on the UPS have been changed, possibly altering UPS performance.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.16\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
17. SEVERE:The batteries of the UPS need immediate replacement.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.17\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
18. SEVERE:One of the contacts on the Environmental Monitor has changed from its default position. The first variable is the contact number that is faulted.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.18\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
19. INFORMATIONAL:A fault on one of the Environmental Monitor contacts has been resolved. The first variable is the contact number that has been resolved.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.19\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
20. SEVERE:UPS on bypass due to internal fault
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.20\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
21. WARNING:UPS on bypass - user set via software or panel
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.21\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
22. WARNING:UPS on bypass - initiated by user
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.22\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
23. INFORMATIONAL:UPS has returned from bypass
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.23\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
24. SEVERE:Base module bypass power supply needs repair
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.24\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
25. SEVERE:Base module fan needs repair
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.25\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
26. SEVERE:Check installation of external battery packs signal cable
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.26\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
27. INFORMATIONAL:UPS is communicating with the external battery packs.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.27\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
28. INFORMATIONAL:A battery calibration test has been initiated on the UPS.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.28\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
29. INFORMATIONAL:Agent restarting as commanded by manager.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.29\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
30. INFORMATIONAL:A UPS is turned on.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.30\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
31. WARNING:The UPS is reducing the line voltage via SmartTrim(TM).
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.31\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
32. INFORMATIONAL:Authentication on agent code image is done.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.32\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
33. INFORMATIONAL:The overload condition has been cleared.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.33\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
34. INFORMATIONAL:The UPS has returned from SmartBoost(TM).
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.34\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
35. INFORMATIONAL:The UPS has returned from SmartTrim(TM).
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.35\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
36. INFORMATIONAL:A bad battery fault has been cleared.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.36\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
37. INFORMATIONAL:The UPS has finished calibrating.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.37\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
38. INFORMATIONAL:A UPS discharge condition has been cleared.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.38\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
39. INFORMATIONAL:A graceful shutdown has been initiated.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.39\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
41. WARNING:The specified PDU outlet has turned on. If sPDUOutletControlIndex equals zero, then all outlets have turned on.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.41\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
42. WARNING:The specified PDU outlet has turned off. If sPDUOutletControlIndex equals zero, then all outlets have turned off.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.42\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
43. WARNING:The specified PDU outlet has rebooted. If sPDUOutletControlIndex equals zero, then all outlets have rebooted.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.43\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
44. WARNING:The SNMP configuration has been changed.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.44\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
45. WARNING:The specified PDU outlet has changed configuration. If sPDUOutletConfigIndex equals zero, then the Master outlet has changed configuration.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.45\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
46. WARNING:Someone has attempted to login via the console with the incorrect password.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.46\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
47. WARNING:Someone has attempted to login via HTTP with the incorrect password.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.47\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
48. WARNING:The password for the device has been changed.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.48\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
49. WARNING:The output voltage is not within acceptable range.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.49\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
50. INFORMATIONAL:The output voltage has returned to an acceptable level.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.50\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
51. WARNING:The battery charger has failed.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.51\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
52. INFORMATIONAL:The battery charger failure condition has been cleared.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.52\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
53. WARNING:The battery temperature threshold has been violated.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.53\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
54. INFORMATIONAL:The battery over temperature has been cleared.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.54\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
55. WARNING:SmartBoost(TM) or SmartTrim(TM) relay fault.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.55\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
56. INFORMATIONAL:SmartBoost(TM) or SmartTrim(TM) relay fault has been cleared.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.56\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
57. SEVERE:Probe 1 humidity threshold violated. The first variable is the current humidity.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.57\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
58. INFORMATIONAL:An Environmental Monitor humidity threshold violation has been cleared on probe 1.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.58\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
59. SEVERE:An Environmental Monitor temperature threshold has been violated on probe 1. The first variable is the current temperature.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.59\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
60. INFORMATIONAL:An Environmental Monitor temperature threshold violation has been cleared on probe 1.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.60\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
61. SEVERE:An Environmental Monitor humidity threshold has been violated on probe 2. The first variable is the current humidity.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.61\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
62. INFORMATIONAL:An Environmental Monitor humidity threshold violation has been cleared on probe 2.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.62\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
63. SEVERE:An Environmental Monitor temperature threshold has been violated on probe 2. The first variable is the current temperature.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.63\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
64. INFORMATIONAL:An Environmental Monitor temperature threshold violation has been cleared on probe 2.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.64\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
65. INFORMATIONAL:Communication with the Environmental Monitor has been established.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.65\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
66. SEVERE:Communication to the Environmental Monitor has been lost. Steps to reestablish communication are in progress.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.66\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
67. INFORMATIONAL:The number of batteries has increased.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.67\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
68. INFORMATIONAL:The number of batteries has decreased.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.68\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
69. INFORMATIONAL:The number of power modules has increased.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.69\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
70. INFORMATIONAL:The number of power modules has decreased.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.70\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
71. INFORMATIONAL:An intelligence module has been inserted.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.71\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
72. INFORMATIONAL:An intelligence module has been removed.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.72\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
73. INFORMATIONAL:A redundant intelligence module has been inserted.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.73\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
74. INFORMATIONAL:A redundant intelligence module has been removed.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.74\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
75. INFORMATIONAL:An external battery frame has been added.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.75\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
76. INFORMATIONAL:An external battery frame has been removed.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.76\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
77. SEVERE:An abnormal condition has been detected. The first variable is the fault condition.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.77\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
78. INFORMATIONAL:An abnormal condition has been cleared. The first variable is the fault condition.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.78\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
79. INFORMATIONAL:The status of the device being monitored has changed.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.79\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
80. WARNING:The UPS has no batteries attached.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.80\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
81. INFORMATIONAL:The UPS's batteries have been attached.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.81\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
82. INFORMATIONAL:A new user has been added.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.82\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
83. INFORMATIONAL:A user has been deleted.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.83\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
84. INFORMATIONAL:A user has been modified.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.84\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
85. INFORMATIONAL:Communications with the MasterSwitch VM has been established.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.85\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
86. SEVERE:Communications with the MasterSwitch VM has been lost.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.86\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
87. SEVERE:The MasterSwitch VM in an overload condition."
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.87\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
88. INFORMATIONAL:The overload condition on the MasterSwitch VM has been cleared.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.88\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
89. INFORMATIONAL:An outlet on the MasterSwitch VM has turned on.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.89\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
90. INFORMATIONAL:An outlet on the MasterSwitch VM has turned off.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.90\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
91. INFORMATIONAL:A device configuration change has been made on a MasterSwitch VM.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.91\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
92. INFORMATIONAL:An outlet configuration change has been made on a MasterSwitch VM.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.92\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
93. INFORMATIONAL:The MasterSwitch VM has violated the low load threshold.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.93\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
94. INFORMATIONAL:The low load condition on the MasterSwitch VM has been cleared.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.94\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
95. SEVERE:The MasterSwitch VM is approaching an overload condition.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.95\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
96. INFORMATIONAL:The near overload condition on the MasterSwitch VM has been cleared.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.96\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
97. WARNING:The power supply status of the MasterSwitch VM has changed."
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.97\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
98. INFORMATIONAL:Communications with the MasterSwitch plus has been established.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.98\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
99. SEVERE:Communications with the MasterSwitch plus has been lost.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.99\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
100. INFORMATIONAL:An outlet on the MasterSwitch plus has turned on.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.100\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
101. INFORMATIONAL:An outlet on the MasterSwitch plus has turned off.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.101\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
102. INFORMATIONAL:A device configuration change has been made on a MasterSwitch plus.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.102\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
103. INFORMATIONAL:An outlet configuration change has been made on a MasterSwitch plus.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.103\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
104. INFORMATIONAL:The Redundant Switch has switched source.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.104\s"]
0
30d
0
0
2
0
0
0
0
INFORMATIONAL:The Redundant Switch has switched source.
The first variable is an integer representing the current source:0=A, 1=B.
The second variable is the 32-character name of the current source.
The third variable is an integer representing the transfer cause:
0=No Transfers Recorded, 1=Due to user action or preferred switching,
3=Due to line notch or spike, 5=Due to low line voltage,
7=Transfer due to high line voltage,
9=Transfer due to frequency out of range.
The fourth variable is a character string listing the transfer cause.
0
SNMP traps
-
105. SEVERE:The Redundant Switch has lost redundancy.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.105\s"]
0
30d
0
0
2
0
0
0
0
SEVERE:The Redundant Switch has lost redundancy.
The first variable is an integer representing the source which is no longer available:0=A, 1=B.
The second variable is the 32-character name of the source which is no longer available.
0
SNMP traps
-
106. INFORMATIONAL:Redundancy has been restored to the Redundant Switch.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.106\s"]
0
30d
0
0
2
0
0
0
0
INFORMATIONAL:Redundancy has been restored to the Redundant Switch.
The first variable is an integer representing the source which has been restored:0=A, 1=B.
The second variable is the 32-character name of the source which has been restored.
0
SNMP traps
-
107. INFORMATIONAL:A configuration change has been made on a Redundant Switch.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.107\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
108. INFORMATIONAL:Communications with the Redundant Switch has been established.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.108\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
109. SEVERE:Communications with the Redundant Switch has been lost.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.109\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
110. INFORMATIONAL:Communications with the DC power plant has been established.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.110\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
-
636. INFORMATIONAL:Trap used to test SNMP trap functionality. The first argument is a place holder for test variables.
17
snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.636\s"]
0
30d
0
0
2
0
0
0
0
0
SNMP traps
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.1\s"].nodata(86400)}=0
0
1. SEVERE:Communication to the UPS has been lost. Steps to reestablish communication are in progress.
0
0
3
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.2\s"].nodata(86400)}=0
0
2. SEVERE:The UPS has sensed a load greater than 100 percent of its rated capacity.
0
0
3
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.3\s"].nodata(86400)}=0
0
3. SEVERE:The UPS failed its internal diagnostic self-test.
0
0
3
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.4\s"].nodata(86400)}=0
0
4. SEVERE:The UPS batteries are discharged;if utility power fails an immediate low battery condition will exist. Sufficient runtime for necessary action cannot be guaranteed.
0
0
3
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.5\s"].nodata(86400)}=0
0
5. WARNING:The UPS has switched to battery backup power.
0
0
2
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.6\s"].nodata(86400)}=0
0
6. WARNING:The UPS has enabled SmartBoost(TM).
0
0
2
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.7\s"].nodata(86400)}=0
0
7. SEVERE:The UPS batteries are low and will soon be exhausted. If utility power is not restored the UPS will put itself to 'sleep' and immediately cut power to the load.
0
0
3
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.8\s"].nodata(86400)}=0
0
8. INFORMATIONAL:Communication with the UPS has been established.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.9\s"].nodata(86400)}=0
0
9. INFORMATIONAL:Utility power has been restored.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.10\s"].nodata(86400)}=0
0
10. INFORMATIONAL:The UPS passed its internal self-test.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.11\s"].nodata(86400)}=0
0
11. INFORMATIONAL:The UPS has returned from a low battery condition.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.12\s"].nodata(86400)}=0
0
12. WARNING:The UPS has been turned 'off' by the management station.
0
0
2
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.13\s"].nodata(86400)}=0
0
13. WARNING:The UPS is entering 'sleep' mode. Power to the load will be cut off.
0
0
2
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.14\s"].nodata(86400)}=0
0
14. INFORMATION:The UPS has returned from 'sleep' mode. Power to the load has been restored.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.15\s"].nodata(86400)}=0
0
15. WARNING:The UPS has started its reboot sequence. The UPS will reboot itself at this time.
0
0
2
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.16\s"].nodata(86400)}=0
0
16. WARNING:The dip switch settings on the UPS have been changed, possibly altering UPS performance.
0
0
2
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.17\s"].nodata(86400)}=0
0
17. SEVERE:The batteries of the UPS need immediate replacement.
0
0
3
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.18\s"].nodata(86400)}=0
0
18. SEVERE:One of the contacts on the Environmental Monitor has changed from its default position. The first variable is the contact number that is faulted.
0
0
3
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.19\s"].nodata(86400)}=0
0
19. INFORMATIONAL:A fault on one of the Environmental Monitor contacts has been resolved. The first variable is the contact number that has been resolved.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.20\s"].nodata(86400)}=0
0
20. SEVERE:UPS on bypass due to internal fault
0
0
3
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.21\s"].nodata(86400)}=0
0
21. WARNING:UPS on bypass - user set via software or panel
0
0
2
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.22\s"].nodata(86400)}=0
0
22. WARNING:UPS on bypass - initiated by user
0
0
2
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.23\s"].nodata(86400)}=0
0
23. INFORMATIONAL:UPS has returned from bypass
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.24\s"].nodata(86400)}=0
0
24. SEVERE:Base module bypass power supply needs repair
0
0
3
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.25\s"].nodata(86400)}=0
0
25. SEVERE:Base module fan needs repair
0
0
3
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.26\s"].nodata(86400)}=0
0
26. SEVERE:Check installation of external battery packs signal cable
0
0
3
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.27\s"].nodata(86400)}=0
0
27. INFORMATIONAL:UPS is communicating with the external battery packs.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.28\s"].nodata(86400)}=0
0
28. INFORMATIONAL:A battery calibration test has been initiated on the UPS.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.29\s"].nodata(86400)}=0
0
29. INFORMATIONAL:Agent restarting as commanded by manager.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.30\s"].nodata(86400)}=0
0
30. INFORMATIONAL:A UPS is turned on.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.31\s"].nodata(86400)}=0
0
31. WARNING:The UPS is reducing the line voltage via SmartTrim(TM).
0
0
2
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.32\s"].nodata(86400)}=0
0
32. INFORMATIONAL:Authentication on agent code image is done.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.33\s"].nodata(86400)}=0
0
33. INFORMATIONAL:The overload condition has been cleared.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.34\s"].nodata(86400)}=0
0
34. INFORMATIONAL:The UPS has returned from SmartBoost(TM).
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.35\s"].nodata(86400)}=0
0
35. INFORMATIONAL:The UPS has returned from SmartTrim(TM).
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.36\s"].nodata(86400)}=0
0
36. INFORMATIONAL:A bad battery fault has been cleared.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.37\s"].nodata(86400)}=0
0
37. INFORMATIONAL:The UPS has finished calibrating.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.38\s"].nodata(86400)}=0
0
38. INFORMATIONAL:A UPS discharge condition has been cleared.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.39\s"].nodata(86400)}=0
0
39. INFORMATIONAL:A graceful shutdown has been initiated.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.41\s"].nodata(86400)}=0
0
41. WARNING:The specified PDU outlet has turned on. If sPDUOutletControlIndex equals zero, then all outlets have turned on.
0
0
2
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.42\s"].nodata(86400)}=0
0
42. WARNING:The specified PDU outlet has turned off. If sPDUOutletControlIndex equals zero, then all outlets have turned off.
0
0
2
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.43\s"].nodata(86400)}=0
0
43. WARNING:The specified PDU outlet has rebooted. If sPDUOutletControlIndex equals zero, then all outlets have rebooted.
0
0
2
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.44\s"].nodata(86400)}=0
0
44. WARNING:The SNMP configuration has been changed.
0
0
2
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.45\s"].nodata(86400)}=0
0
45. WARNING:The specified PDU outlet has changed configuration. If sPDUOutletConfigIndex equals zero, then the Master outlet has changed configuration.
0
0
2
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.46\s"].nodata(86400)}=0
0
46. WARNING:Someone has attempted to login via the console with the incorrect password.
0
0
2
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.47\s"].nodata(86400)}=0
0
47. WARNING:Someone has attempted to login via HTTP with the incorrect password.
0
0
2
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.48\s"].nodata(86400)}=0
0
48. WARNING:The password for the device has been changed.
0
0
2
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.49\s"].nodata(86400)}=0
0
49. WARNING:The output voltage is not within acceptable range.
0
0
2
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.50\s"].nodata(86400)}=0
0
50. INFORMATIONAL:The output voltage has returned to an acceptable level.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.51\s"].nodata(86400)}=0
0
51. WARNING:The battery charger has failed.
0
0
2
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.52\s"].nodata(86400)}=0
0
52. INFORMATIONAL:The battery charger failure condition has been cleared.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.53\s"].nodata(86400)}=0
0
53. WARNING:The battery temperature threshold has been violated.
0
0
2
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.54\s"].nodata(86400)}=0
0
54. INFORMATIONAL:The battery over temperature has been cleared.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.55\s"].nodata(86400)}=0
0
55. WARNING:SmartBoost(TM) or SmartTrim(TM) relay fault.
0
0
2
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.56\s"].nodata(86400)}=0
0
56. INFORMATIONAL:SmartBoost(TM) or SmartTrim(TM) relay fault has been cleared.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.57\s"].nodata(86400)}=0
0
57. SEVERE:Probe 1 humidity threshold violated. The first variable is the current humidity.
0
0
3
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.58\s"].nodata(86400)}=0
0
58. INFORMATIONAL:An Environmental Monitor humidity threshold violation has been cleared on probe 1.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.59\s"].nodata(86400)}=0
0
59. SEVERE:An Environmental Monitor temperature threshold has been violated on probe 1. The first variable is the current temperature.
0
0
3
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.60\s"].nodata(86400)}=0
0
60. INFORMATIONAL:An Environmental Monitor temperature threshold violation has been cleared on probe 1.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.61\s"].nodata(86400)}=0
0
61. SEVERE:An Environmental Monitor humidity threshold has been violated on probe 2. The first variable is the current humidity.
0
0
3
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.62\s"].nodata(86400)}=0
0
62. INFORMATIONAL:An Environmental Monitor humidity threshold violation has been cleared on probe 2.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.63\s"].nodata(86400)}=0
0
63. SEVERE:An Environmental Monitor temperature threshold has been violated on probe 2. The first variable is the current temperature.
0
0
3
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.64\s"].nodata(86400)}=0
0
64. INFORMATIONAL:An Environmental Monitor temperature threshold violation has been cleared on probe 2.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.65\s"].nodata(86400)}=0
0
65. INFORMATIONAL:Communication with the Environmental Monitor has been established.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.66\s"].nodata(86400)}=0
0
66. SEVERE:Communication to the Environmental Monitor has been lost. Steps to reestablish communication are in progress.
0
0
3
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.67\s"].nodata(86400)}=0
0
67. INFORMATIONAL:The number of batteries has increased.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.68\s"].nodata(86400)}=0
0
68. INFORMATIONAL:The number of batteries has decreased.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.69\s"].nodata(86400)}=0
0
69. INFORMATIONAL:The number of power modules has increased.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.70\s"].nodata(86400)}=0
0
70. INFORMATIONAL:The number of power modules has decreased.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.71\s"].nodata(86400)}=0
0
71. INFORMATIONAL:An intelligence module has been inserted.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.72\s"].nodata(86400)}=0
0
72. INFORMATIONAL:An intelligence module has been removed.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.73\s"].nodata(86400)}=0
0
73. INFORMATIONAL:A redundant intelligence module has been inserted.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.74\s"].nodata(86400)}=0
0
74. INFORMATIONAL:A redundant intelligence module has been removed.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.75\s"].nodata(86400)}=0
0
75. INFORMATIONAL:An external battery frame has been added.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.76\s"].nodata(86400)}=0
0
76. INFORMATIONAL:An external battery frame has been removed.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.77\s"].nodata(86400)}=0
0
77. SEVERE:An abnormal condition has been detected. The first variable is the fault condition.
0
0
3
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.78\s"].nodata(86400)}=0
0
78. INFORMATIONAL:An abnormal condition has been cleared. The first variable is the fault condition.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.79\s"].nodata(86400)}=0
0
79. INFORMATIONAL:The status of the device being monitored has changed.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.80\s"].nodata(86400)}=0
0
80. WARNING:The UPS has no batteries attached.
0
0
2
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.81\s"].nodata(86400)}=0
0
81. INFORMATIONAL:The UPS's batteries have been attached.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.82\s"].nodata(86400)}=0
0
82. INFORMATIONAL:A new user has been added.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.83\s"].nodata(86400)}=0
0
83. INFORMATIONAL:A user has been deleted.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.84\s"].nodata(86400)}=0
0
84. INFORMATIONAL:A user has been modified.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.85\s"].nodata(86400)}=0
0
85. INFORMATIONAL:Communications with the MasterSwitch VM has been established.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.86\s"].nodata(86400)}=0
0
86. SEVERE:Communications with the MasterSwitch VM has been lost.
0
0
3
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.87\s"].nodata(86400)}=0
0
87. SEVERE:The MasterSwitch VM in an overload condition."
0
0
3
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.88\s"].nodata(86400)}=0
0
88. INFORMATIONAL:The overload condition on the MasterSwitch VM has been cleared.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.89\s"].nodata(86400)}=0
0
89. INFORMATIONAL:An outlet on the MasterSwitch VM has turned on.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.90\s"].nodata(86400)}=0
0
90. INFORMATIONAL:An outlet on the MasterSwitch VM has turned off.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.91\s"].nodata(86400)}=0
0
91. INFORMATIONAL:A device configuration change has been made on a MasterSwitch VM.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.92\s"].nodata(86400)}=0
0
92. INFORMATIONAL:An outlet configuration change has been made on a MasterSwitch VM.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.93\s"].nodata(86400)}=0
0
93. INFORMATIONAL:The MasterSwitch VM has violated the low load threshold.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.94\s"].nodata(86400)}=0
0
94. INFORMATIONAL:The low load condition on the MasterSwitch VM has been cleared.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.95\s"].nodata(86400)}=0
0
95. SEVERE:The MasterSwitch VM is approaching an overload condition.
0
0
3
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.96\s"].nodata(86400)}=0
0
96. INFORMATIONAL:The near overload condition on the MasterSwitch VM has been cleared.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.97\s"].nodata(86400)}=0
0
97. WARNING:The power supply status of the MasterSwitch VM has changed."
0
0
2
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.98\s"].nodata(86400)}=0
0
98. INFORMATIONAL:Communications with the MasterSwitch plus has been established.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.99\s"].nodata(86400)}=0
0
99. SEVERE:Communications with the MasterSwitch plus has been lost.
0
0
3
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.100\s"].nodata(86400)}=0
0
100. INFORMATIONAL:An outlet on the MasterSwitch plus has turned on.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.101\s"].nodata(86400)}=0
0
101. INFORMATIONAL:An outlet on the MasterSwitch plus has turned off.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.102\s"].nodata(86400)}=0
0
102. INFORMATIONAL:A device configuration change has been made on a MasterSwitch plus."
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.103\s"].nodata(86400)}=0
0
103. INFORMATIONAL:An outlet configuration change has been made on a MasterSwitch plus.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.104\s"].nodata(86400)}=0
0
104. INFORMATIONAL:The Redundant Switch has switched source.
0
0
1
INFORMATIONAL:The Redundant Switch has switched source.
The first variable is an integer representing the current source:0=A, 1=B.
The second variable is the 32-character name of the current source.
The third variable is an integer representing the transfer cause:
0=No Transfers Recorded, 1=Due to user action or preferred switching,
3=Due to line notch or spike, 5=Due to low line voltage,
7=Transfer due to high line voltage,
9=Transfer due to frequency out of range.
The fourth variable is a character string listing the transfer cause.
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.105\s"].nodata(86400)}=0
0
105. SEVERE:The Redundant Switch has lost redundancy.
0
0
3
SEVERE:The Redundant Switch has lost redundancy.
The first variable is an integer representing the source which is no longer available:0=A, 1=B.
The second variable is the 32-character name of the source which is no longer available.
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.106\s"].nodata(86400)}=0
0
106. INFORMATIONAL:Redundancy has been restored to the Redundant Switch.
0
0
1
INFORMATIONAL:Redundancy has been restored to the Redundant Switch.
The first variable is an integer representing the source which has been restored:0=A, 1=B.
The second variable is the 32-character name of the source which has been restored.
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.107\s"].nodata(86400)}=0
0
107. INFORMATIONAL:A configuration change has been made on a Redundant Switch.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.108\s"].nodata(86400)}=0
0
108. INFORMATIONAL:Communications with the Redundant Switch has been established.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.109\s"].nodata(86400)}=0
0
109. SEVERE:Communications with the Redundant Switch has been lost.
0
0
3
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.110\s"].nodata(86400)}=0
0
110. INFORMATIONAL:Communications with the DC power plant has been established.
0
0
1
0
0
{APC Rack PDU:snmptrap["\s\.1\.3\.6\.1\.4\.1\.318\.0\.636\s"].nodata(86400)}=0
0
636. INFORMATIONAL:Trap used to test SNMP trap functionality. The first argument is a place holder for test variables.
0
0
1
0
0
{APC Rack PDU:snmptrap.fallback.nodata(172800)}=0
0
Неизвестная ошибка
0
0
0
0
0