Events and Messages

Events and Messages

This topic lists the MegaRAID Storage Manager events that can appear in the event log.

The MegaRAID Storage Manager software monitors the activity and the performance of all controllers in the server and the devices attached to them. When an event occurs, such as the removal of a drive or the creation of a new drive group, an event message appears in the log at the bottom of the MegaRAID Storage Manager main menu. The messages are also logged in the Windows Application log (Event Viewer).

Each message that appears in the event log has a severity level that indicates the category of the event, as the following table shows.

Table 3. Event Error Levels

Severity Level

Meaning

Information

Informational message. No user action is necessary.

Warning

Some component might be close to a failure point.

Critical

A component has failed, but the system has not lost data.

Fatal

A component has failed, and data loss has occurred or will occur.

The following table lists all of the MegaRAID Storage Manager event messages. The event message descriptions include placeholders for specific values that are determined when the event is generated. For example, in message No. 1 (0x0001) in the Event Messages table, %s is replaced by the firmware version, which is read from the firmware when the event is generated.

Table 4. Event Messages

Number

Type

Event Text

0x0000

Information

MegaRAID firmware initialization started (PCI ID %04x/%04x/%04x/%04x)

0x0001

Information

MegaRAID firmware version %s

0x0002

Fatal

Unable to recover cache data from TBBU

0x0003

Information

Cache data recovered from TBBU successfully

0x0004

Information

Configuration cleared

0x0005

Warning

Cluster down; communication with peer lost

0x0006

Information

Virtual drive %s ownership changed from %02x to %02x

0x0009

Information

Background initialization rate changed to %d%%

0x000a

Fatal

Controller cache discarded due to memory/battery problems

0x000b

Fatal

Unable to recover cache data due to configuration mismatch

0x000c

Information

Cache data recovered successfully

0x000d

Fatal

Controller cache discarded due to firmware version incompatibility

0x000e

Information

Consistency Check rate changed to %d%%

0x000f

Fatal

Fatal firmware error: %s

0x0010

Information

Factory defaults restored

0x0011

Information

Flash downloaded image corrupt

0x0012

Critical

Flash erase error

0x0013

Critical

Flash timeout during erase

0x0014

Critical

Flash error

0x0015

Information

Flashing image: %s

0x0016

Information

Flash of new firmware image(s) complete

0x0017

Critical

Flash programming error

0x0018

Critical

Flash timeout during programming

0x0019

Critical

Flash chip type unknown

0x001a

Critical

Flash command set unknown

0x001b

Critical

Flash verify failure

0x001c

Information

Flush rate changed to %d seconds

0x001d

Information

Hibernate command received from host

0x001e

Information

Event log cleared

0x001f

Information

Event log wrapped

0x0020

Fatal

Multi-bit ECC error: ECAR=%x, ELOG=%x, (%s)

0x0021

Warning

Single-bit ECC error: ECAR=%x, ELOG=%x, (%s)

0x0022

Fatal

Not enough controller memory

0x002a

Information

Shutdown command received from host

0x002b

Information

Test event: %s

0x002c

Information

Time established as %s; (%d seconds since power on)

0x002d

Information

User entered firmware debugger

0x002e

Warning

Background Initialization aborted on %s

0x002f

Warning

Background Initialization corrected medium error (%s at %lx

0x0030

Information

Background Initialization completed on %s

0x0031

Fatal

Background Initialization completed with uncorrectable errors on %s

0x0032

Fatal

Background Initialization detected uncorrectable double medium errors (%s at %lx on %s)

0x0033

Critical

Background Initialization failed on %s

0x0034

Progress

Background Initialization progress on %s is %s

0x0035

Information

Background Initialization started on %s

0x0036

Information

Policy change on %s from %s to %s

0x0038

Warning

Consistency Check aborted on %s

0x0039

Warning

Consistency Check corrected medium error on %s at %lx

0x003a

Information

Consistency Check done on %s

0x003b

Information

Consistency Check done with corrections on %s

0x003c

Fatal

Consistency Check detected uncorrectable double medium errors (%s at %lx on %s)

0x003d

Critical

Consistency Check failed on %s

0x003e

Fatal

Consistency Check completed with uncorrectable data on %s

0x003f

Warning

Consistency Check found inconsistent parity on %s at strip %lx

0x0040

Warning

Consistency Check inconsistency logging disabled on %s (too many inconsistencies)

0x0041

Progress

Consistency Check progress on %s is %s

0x0042

Information

Consistency Check started on %s

0x0043

Warning

Initialization aborted on %s

0x0044

Critical

Initialization failed on %s

0x0045

Progress

Initialization progress on %s is %s

0x0046

Information

Fast initialization started on %s

0x0047

Information

Full initialization started on %s

0x0048

Information

Initialization complete on %s

0x0049

Information

LD Properties updated to %s (from %s)

0x0050

Information

Modifying drive group started on %s

0x0051

Information

State change on %s from %s to %s

0x0052

Information

Drive Clear aborted on %s

0x0053

Critical

Drive Clear failed on %s (Error %02x)

0x0054

Progress

Drive Clear progress on %s is %s

0x0055

Information

Drive Clear started on %s

0x0056

Information

Drive Clear completed on %s

0x0057

Warning

Error on %s (Error %02x)

0x0058

Information

Format complete on %s

0x0059

Information

Format started on %s

0x005a

Critical

Hot Spare SMART polling failed on %s (Error %02x)

0x005b

Information

Drive inserted: %s

0x005c

Warning

Drive %s is not supported

0x0060

Critical

Predictive failure: CDB: %s

0x0063

Information

Rebuild complete on %s

0x0064

Information

Rebuild complete on %s

0x0065

Critical

Rebuild failed on %s due to source drive error

0x0066

Critical

Rebuild failed on %s due to target drive error

0x0067

Progress

Rebuild progress on %s is %s

0x0069

Information

Rebuild started on %s

0x006a

Information

Rebuild automatically started on %s

0x006b

Critical

Rebuild stopped on %s due to loss of cluster ownership

0x006c

Fatal

Reassign write operation failed on %s at %lx

0x006d

Fatal

Unrecoverable medium error during rebuild on %s at %lx

0x006e

Information

Corrected medium error during recovery on %s at %lx

0x006f

Fatal

Unrecoverable medium error during recovery on %s at %lx

0x0070

Information

Drive removed: %s

0x0071

Warning

Unexpected sense: %s, CDB%s, Sense: %s

0x0072

Information

State change on %s from %s to %s

0x0073

Information

State change by user on %s from %s to %s

0x0074

Warning

Redundant path to %s broken

0x0075

Information

Redundant path to %s restored

0x0077

Critical

SAS topology error: Loop detected

0x0078

Critical

SAS topology error: Unaddressable device

0x0079

Critical

SAS topology error: Multiple ports to the same SAS address

0x007a

Critical

SAS topology error: Expander error

0x007b

Critical

SAS topology error: SMP timeout

0x007c

Critical

SAS topology error: Out of route entries

0x007d

Critical

SAS topology error: Index not found

0x007e

Critical

SAS topology error: SMP function failed

0x007f

Critical

SAS topology error: SMP CRC error

0x0080

Critical

SAS topology error: Multiple subtractive

0x0081

Critical

SAS topology error: Table to table

0x0082

Critical

SAS topology error: Multiple paths

0x0083

Fatal

Unable to access device %s

0x0087

Information

Global Hot Spare created on %s (%s)

0x0088

Information

Global Hot Spare %s disabled

0x0089

Critical

Global Hot Spare does not cover all drive groups

0x008a

Information

Created %s

0x008b

Information

Deleted %s

0x008c

Information

Marking LD %s inconsistent due to active writes at shutdown

0x00a4

Information

Enclosure (SES) discovered on %s

0x00a5

Information

Enclosure (SAFTE) discovered on %s

0x00a6

Critical

Enclosure %s communication lost

0x00a7

Information

Enclosure %s communication restored

0x00a8

Critical

Enclosure %s fan %d failed

0x00a9

Information

Enclosure %s fan %d inserted

0x00aa

Critical

Enclosure %s fan %d removed

0x00ab

Critical

Enclosure %s power supply %d failed

0x00ac

Information

Enclosure %s power supply %d inserted

0x00ad

Critical

Enclosure %s power supply %d removed

0x00ae

Critical

Enclosure %s SIM %d failed

0x00af

Information

Enclosure %s SIM %d inserted

0x00b0

Critical

Enclosure %s SIM %d removed

0x00b1

Warning

Enclosure %s temperature sensor %d below warning threshold

0x00b2

Critical

Enclosure %s temperature sensor %d below error threshold

0x00b3

Warning

Enclosure %s temperature sensor %d above warning threshold

0x00b4

Critical

Enclosure %s temperature sensor %d above error threshold

0x00b5

Critical

Enclosure %s shutdown

0x00b6

Warning

Enclosure %s not supported; too many enclosures connected to port

0x00b7

Critical

Enclosure %s firmware mismatch

0x00b8

Warning

Enclosure %s sensor %d bad

0x00b9

Critical

Enclosure %s phy %d bad

0x00ba

Critical

Enclosure %s is unstable

0x00bb

Critical

Enclosure %s hardware error

0x00bc

Critical

Enclosure %s not responding

0x00bd

Information

SAS/SATA mixing not supported in enclosure; Drive %s disabled

0x00be

Information

Enclosure (SES) hotplug on %s was detected, but is not supported

0x00bf

Information

Clustering enabled

0x00c0

Information

Clustering disabled

0x00c1

Information

Drive too small to be used for auto-rebuild on %s

0x00c4

Warning

Bad block table on drive %s is 80% full

0x00c5

Fatal

Bad block table on drive %s is full; unable to log block %lx

0x00c6

Information

Consistency Check Aborted due to ownership loss on %s

0x00c7

Information

Background Initialization (BGI) Aborted Due to Ownership Loss on %s

0x00c9

Warning

Single-bit ECC error: ECAR=%x, ELOG=%x, (%s); warning threshold exceeded

0x00ca

Critical

Single-bit ECC error: ECAR=%x, ELOG=%x, (%s); critical threshold exceeded

0x00cb

Critical

Single-bit ECC error: ECAR=%x, ELOG=%x, (%s); further reporting disabled

0x00cc

Critical

Enclosure %s Power supply %d switched off

0x00cd

Information

Enclosure %s Power supply %d switched on

0x00ce

Critical

Enclosure %s Power supply %d cable removed

0x00cf

Information

Enclosure %s Power supply %d cable inserted

0x00d0

Information

Enclosure %s Fan %d returned to normal

0x00d4

Information

NVRAM Retention test was initiated on previous boot

0x00d5

Information

NVRAM Retention test passed

0x00d6

Critical

NVRAM Retention test failed!

0x00d7

Information

%s test completed %d passes successfully

0x00d8

Critical

%s test FAILED on %d pass. Fail data: errorOffset=%x goodData=%x badData=%x

0x00d9

Information

Self check diagnostics completed

0x00da

Information

Foreign Configuration detected

0x00db

Information

Foreign Configuration imported

0x00dc

Information

Foreign Configuration cleared

0x00dd

Warning

NVRAM is corrupt; reinitializing

0x00de

Warning

NVRAM mismatch occurred

0x00df

Warning

SAS wide port %d lost link on PHY %d

0x00e0

Information

SAS wide port %d restored link on PHY %d

0x00e1

Warning

SAS port %d, PHY %d has exceeded the allowed error rate

0x00e2

Warning

Bad block reassigned on %s at %lx to %lx

0x00e3

Information

Controller Hot Plug detected

0x00e4

Warning

Enclosure %s temperature sensor %d differential detected

0x00e5

Information

Drive test cannot start. No qualifying drives found

0x00e6

Information

Time duration provided by host is not sufficient for self check

0x00e9

Information

Enclosure %s Temperature %d returned to normal

0x00ea

Information

Enclosure %s Firmware download in progress

0x00eb

Warning

Enclosure %s Firmware download failed

0x00ec

Warning

%s is not a certified drive

0x00ed

Information

Dirty cache data discarded by user

0x00ee

Information

Drives missing from configuration at boot

0x00ef

Information

Virtual drives (VDs) missing drives and will go offline at boot: %s

0x00f0

Information

VDs missing at boot: %s

0x00f1

Information

Previous configuration completely missing at boot

0x00f3

Information

Enclosure %s fan %d speed changed

0x00f5

Information

%s rebuild not possible as SAS/SATA is not supported in an array

0x00f6

Information

SEP %s has been rebooted as a part of enclosure firmware download. SEP will be unavailable until this process completes.

0x00f7

Information

Inserted physical drive (PD): %s Info: %s

0x00f8

Information

Removed PD: %s Info: %s

0x00f9

Information

VD %s is now OPTIMAL

0x00fa

Warning

VD %s is now PARTIALLY DEGRADED

0x00fb

Critical

VD %s is now DEGRADED

0x00fc

Fatal

VD %s is now OFFLINE

0x00fe

Warning

VD %s disabled because RAID-5 is not supported by this RAID key

0x00ff

Warning

VD %s disabled because RAID-6 is not supported by this controller

0x0100

Warning

VD %s disabled because SAS drives are not supported by this RAID key

0x0101

Warning

PD missing: %s

0x0102

Warning

Puncturing of LBAs enabled

0x0103

Warning

Puncturing of LBAs disabled

0x0104

Critical

Enclosure %s EMM %d not installed

0x0105

Information

Package version %s

0x0106

Warning

Global affinity Hot Spare %s commissioned in a different enclosure

0x0107

Warning

Foreign configuration table overflow

0x0108

Warning

Partial foreign configuration imported, PDs not imported:%s

0x0109

Information

Connector %s is active

0x010a

Information

Board Revision %s

0x010b

Warning

Command timeout on PD %s, CDB:%s

0x010c

Warning

PD %s reset (Type %02x)

0x010d

Warning

VD bad block table on %s is 80% full

0x010e

Fatal

VD bad block table on %s is full; unable to log block %lx (on %s at %lx)

0x010f

Fatal

Uncorrectable medium error logged for %s at %lx (on %s at %lx)

0x0110

Information

VD medium error corrected on %s at %lx

0x0111

Warning

Bad block table on PD %s is 100% full

0x0112

Warning

VD bad block table on PD %s is 100% full

0x0113

Fatal

Controller needs replacement, IOP is faulty

0x011b

Warning

Early Power off warning was unsuccessful

0x011d

Information

%s FRU is %s

0x011e

Information

Controller hardware revision ID %s

0x011f

Warning

Foreign import shall result in a backward incompatible upgrade of configuration metadata

0x0120

Information

Redundant path restored for PD %s

0x0121

Warning

Redundant path broken for PD %s

0x0122

Information

Redundant enclosure EMM %s inserted for EMM %s

0x0123

Information

Redundant enclosure EMM %s removed for EMM %s

0x0128

Fatal

Controller cache discarded for missing or offline VD %s When a VD with cached data goes offline or missing during runtime, the cache for the VD is discarded. Because the VD is offline, the cache cannot be saved.

0x012b

Information

Microcode update started on PD %s

0x012c

Information

Microcode update completed on PD %s

0x012d

Warning

Microcode update timeout on PD %s

0x012e

Warning

Microcode update failed on PD %s

0x012f

Information

Controller properties changed

0x0131

Information

CC Schedule properties changed

0x0133

Warning

Periodic Battery Relearn is pending. Please initiate manual learn cycle as Automatic learn is not enabled

0x013c

Information

VD %s is now secured

0x013d

Warning

VD %s is partially secured

0x013e

Information

PD %s security activated

0x013f

Information

PD %s security disabled

0x0140

Information

PD %s is reprovisioned

0x0141

Information

PD %s security key changed

0x0142

Fatal

Security subsystem problems detected for PD %s

0x0143

Fatal

Controller cache pinned for missing or offline VD %s

0x0144

Fatal

Controller cache pinned for missing or offline VDs: %s

0x0145

Information

Controller cache discarded by user for VDs: %s

0x0146

Information

Controller cache destaged for VD %s

0x0147

Warning

Consistency Check started on an inconsistent VD %s

0x014a

Warning

Detected error with the remote battery connector cable

0x014b

Information

Power state change on PD %s from %s to %s

0x014c

Information

Enclosure %s element (SES code 0x%x) status changed

0x014d

Information

PD %s rebuild not possible as HDD/SSD mix is not supported in a drive group

0x014f

Information

VD bad block table on %s is cleared

0x0150

Information

SAS topology error: 0x%lx

0x0151

Information

VD cluster of medium errors corrected for %s at %lx (on %s at %lx)

0x0152

Information

Controller requests a host bus rescan

0x0153

Information

Controller repurposed and factory defaults restored

0x0157

Information

%s needs key to be %s %s

0x0158

Warning

%s secure failed

0x0159

Critical

Controller encountered a fatal error and was reset

0x016e

Critical

Configuration command could not be committed to disk, please retry

0x016f

Information

COD on %s updated as it was stale

0x0170

Warning

Power state change failed on %s (from %s to %s)

0x0171

Warning

%s is not available

0x0172

Information

%s is available

0x0173

Information

%s is used for CacheCade with capacity 0x%lx logical blocks

0x0174

Information

%s is using CacheCade %s

0x0175

Information

%s is no longer using CacheCade %s

0x0176

Critical

Snapshot deleted due to resource constraints for %s in snapshot repository %s

0x0177

Warning

Auto Snapshot failed for %s in snapshot repository %s

0x0178

Warning

Controller reset on-board expander

0x0179

Warning

CacheCade (%s) capacity changed and is now 0x%lx logical blocks

0x017b

Information

Advanced Software Options %s key was applied for %s

0x017c

Information

Snapshot schedule properties changed on %s

0x017d

Information

Snapshot scheduled action is due on %s

0x017e

Information

Performance Metrics: collection command 0x%lx

0x017f

Information

Advanced Software Options %s key was transferred -%s

0x0180

Information

Advanced Software Options Serial number %s

0x0181

Warning

Advanced Software Options Serial number mismatched. Key Vault Serial number %s

0x0183

Information

%s power policy changed to %s (from %s)

0x0184

Warning

%s cannot transition to max power savings

0x0185

Information

Host driver is loaded and operational

0x0186

Information

%s mirror broken

0x0187

Information

%s mirror joined

0x0188

Warning

%s link %d failure in wide port

0x0189

Information

%s link %d restored in wide port

0x018a

Information

Memory module FRU is %s

0x018b

Warning

Cache-vault power pack is sub-optimal. Please replace the pack

0x018c

Warning

Foreign configuration auto-import did not import any drives

0x018d

Warning

Cache-vault microcode update required

0x018e

Warning

CacheCade(TM) (%s) capacity exceeds maximum allowed size, extra capacity is not used

0x018f

Warning

LD (%s) protection information lost

0x0190

Information

Diagnostics passed for %s

0x0191

Critical

Diagnostics failed for %s

0x0192

Information

Server Power capability Diagnostic Test Started

0x0193

Information

Drive Cache settings enabled during rebuild for %s

0x0194

Information

Drive Cache settings restored after rebuild for %s

0x0195

Information

Drive %s commissioned as Emergency spare

0x0196

Warning

Reminder: Potential non-optimal configuration due to drive %s commissioned as emergency spare

0x01ae

Warning

Potential leakage during erase on %s

0x01b0

Information

NVCache firmware update was successful

0x01b1

Warning

NVCache firmware update failed

0x01b2

Fatal

%s access blocked as cached data in CacheCade(TM) is unavailable

0x01b3

Information

CacheCade(TM) disassociate started on %s

0x01b4

Information

CacheCade(TM) disassociate completed on %s

0x01b5

Critical

CacheCade(TM) disassociate failed on %s

0x01b7

Information

CacheCade(TM) disassociate aborted by user on %s

0x01b8

Information

Link speed changed on SAS port %d and PHY %d

0x01b9

Warning

Advanced Software Options was deactivated for - %s

0x01ba

Information

%s is now accessible

0x01bb

Information

%s is using CacheCade(TM)

0x01bc

Information

%s is no longer using CacheCade(TM)

0xfff9

Critical

Temperature %04x on sensor %04x has exceeded critical temperature threshold %04x

0xfffa

Warning

Temperature %04x on sensor %04x has exceeded warning temperature threshold %04x

0xfffb

Critical

Backup Rail Monitor has failed on %s. Check %s

0xffc

Critical

SSD Life is exhausted Slot Number %04x (Cage %04x Location %s)

0xfffd

Warning

SSD Life is at warning level Slot Number %04x (Cage %04x Location %s) Drive Life %04x Warning Level %04x Error Level %04x" }

0xfffe

Information

SSD throttling is now removed Slot Number %04x (Cage %04x Location %s) Throttle %04x" }

0xffff

Information

SSD is being throttled Slot Number %04x (Cage %04x Location %s)