If a drive in a redundant virtual drive (RAID 1, 5, 6, 10, 50, or 60) fails, the MegaRAID Storage Manager software automatically rebuilds the data on a hot spare drive to prevent data loss. The rebuild is a fully automatic process, so it is not necessary to issue a Rebuild command. You can monitor the progress of drive rebuilds in the Group Show Progress window. To open this window, select Manage > Show Progress.
A red circle to the right of the drive icon indicates that a drive has failed. A yellow circle appears to the right of the icon of the virtual drive that uses this drive which indicates that the virtual drive is in a degraded state; the data is still safe, but data could be lost if another drive fails.
Follow these steps to rebuild a drive:
2.
Click Yes when the warning message appears. If the drive is still good, a rebuild starts.
You can monitor the progress of the rebuild in the Group Show Progress window by selecting Manage > Show Progress. If the drive cannot be rebuilt, an error message appears. Continue with the next step.
When the new drive spins up, the drive icon changes back to normal status, and the rebuild process begins automatically. You can monitor the progress of the rebuild in the Group Show Progress window by selecting Manage > Show Progress.
If you want to force a drive into Fail status to trigger a rebuild, right-click the drive icon, and select Make Drive Offline. A red circle appears next to the drive icon. Right-click the icon, and select Rebuild from the pop-up menu.
DB09000202-21, Rev 2.2, July 2015 |
Copyright© 2015 by Avago Technologies. All rights reserved. |