The following table lists all of the MegaRAID Storage Manager event messages. The event message descriptions include placeholders for specific values that are determined when the event is generated. For example, in message No. 1 in the Event Messages table, “%s” is replaced by the firmware version, which is read from the firmware when the event is generated.

Table 6. Event Messages

Number

Severity Level

Event Text

Generic Conditions when Each Event Occurs

0x0000

Information

MegaRAID firmware initialization started (PCI ID %04x/%04x/%04x/%04x)

Logged at firmware initialization.

0x0001

Information

MegaRAID firmware version %s

Logged at firmware initialization to display firmware version.

0x0002

Fatal

Unable to recover cache data from TBBU

Currently not logged.

0x0003

Information

Cache data recovered from TBBU successfully

Currently not logged.

0x0004

Information

Configuration cleared

Logged when controller configuration is cleared.

0x0005

Warning

Cluster down; communication with peer lost

Currently not logged.

0x0006

Information

Virtual drive %s ownership changed from %02x to %02x

Currently not logged.

0x0007

Information

Alarm disabled by user

Logged when user disables alarm.

0x0008

Information

Alarm enabled by user

Logged when user enables alarm.

0x0009

Information

Background initialization rate changed to %d%%

Logged to display background initialization progress indication in percentage.

0x000a

Fatal

Controller cache discarded due to memory/battery problems

Logged on cache discard due to hardware problems.

0x000b

Fatal

Unable to recover cache data due to configuration mismatch

Currently not logged.

0x000c

Information

Cache data recovered successfully

Logged when cache data is successfully recovered after reboot.

0x000d

Fatal

Controller cache discarded due to firmware version incompatibility

Logged when cache data discarded because of firmware version mismatch.

0x000e

Information

Consistency Check rate changed to %d%%

Logged to display Consistency check progress indication percentage.

0x000f

Fatal

Fatal firmware error: %s

Logged in case of fatal errors and also while entering debug monitor.

0x0010

Information

Factory defaults restored

Logged while controller is reset to factory defaults.

0x0011

Information

Flash downloaded image corrupt

Logged to inform downloaded flash image is corrupt.

0x0012

Critical

Flash erase error

Logged in case of flash erase failure, generally after flash update.

0x0013

Critical

Flash timeout during erase

Logged to indicate flash erase operation timed out.

0x0014

Critical

Flash error

Generic unknown internal error during flash update flash.

0x0015

Information

Flashing image: %s

Logged to display flash image name string before getting updated to controller.

0x0016

Information

Flash of new firmware images complete

Logged to inform successful update of flash image(s).

0x0017

Critical

Flash programming error

Logged to notify, write failure during flash update, not being allowed usually due to internal controller settings.

0x0018

Critical

Flash timeout during programming

Logged to indicate flash write operation timed out.

0x0019

Critical

Flash chip type unknown

Logged during flash update tried with unsupported flash chip type.

0x001a

Critical

Flash command set unknown

Logged while unsupported flash command set detected, most likely because of unsupported flash chip.

0x001b

Critical

Flash verify failure

Logged when compare operation fails between written flash data and original data.

0x001c

Information

Flush rate changed to %d seconds

Logged to notify modified cache flush frequency in seconds.

0x001d

Information

Hibernate command received from host

Logged to inform about reception of hibernation command from host to controller, generally during host shutdown.

0x001e

Information

Event log cleared

Logged when controller log has been cleared.

0x001f

Information

Event log wrapped

Logged when controller log has been wrapped around, when the maximum logs are written.

0x0020

Fatal

Multi-bit ECC error: ECAR=%x, ELOG=%x, (%s)

Logged to notify ECC multi bit error in memory, ELOG: ecc info (source, type, syndrome), ECAR:ecc address.

0x0021

Warning

Single-bit ECC error: ECAR=%x, ELOG=%x, (%s)

Logged to notify ECC single bit error in memory, ELOG: ecc info (source, type, syndrome), ECAR:ecc address.

0x0022

Fatal

Not enough controller memory

Logged to notify fatal controller condition, when you run out of memory to allocate.

0x0023

Information

Patrol Read complete

Logged when patrol read completes.

0x0024

Information

Patrol Read paused

Logged when patrol read is paused.

0x0025

Information

Patrol Read Rate changed to %d%%

Logged to indicate progress of patrol read in percentage.

0x0026

Information

Patrol Read resumed

Logged when patrol read is resumed.

0x0027

Information

Patrol Read started

Logged when patrol read is started.

0x0028

Information

Reconstruction rate changed to %d%%"

Logged to indicate progress of reconstruction in percentage.

0x0029

Information

Drive group modification rate changed to %d%%

Logged to indicate the change in Drive group modification frequency.

0x002a

Information

Shutdown command received from host

Logged when shutdown command is received from host to controller.

0x002b

Information

Test event: %s

General controller event, with a generic string.

0x002c

Information

Time established as %s; (%d seconds since power on)

Logged when controller time was set from host, also displaying time since power on in seconds.

0x002d

Information

User entered firmware debugger

Logged when user enters controller debug shell.

0x002e

Warning

Background Initialization aborted on %s

Logged to inform about user aborted background initialization on displayed LD number.

0x002f

Warning

Background Initialization corrected medium error (%s at %lx

logged to inform about corrected medium error on displayed LD number, LBALBA number, PD number and PDLBA number in that order.

0x0030

Information

Background Initialization completed on %s

Logged to inform Background Initialization completion on displayed LD.

0x0031

Fatal

Background Initialization completed with uncorrectable errors on %s

Logged to inform Background Initialization completion with error on displayed LD.

0x0032

Fatal

Background Initialization detected uncorrectable double medium errors (%s at %lx on %s)

Logged to inform Background Initialization completion with double medium error on displayed PD, PDLBA and LD in that order.

0x0033

Critical

Background Initialization failed on %s

Logged to inform Background Initialization failure on displayed LD.

0x0034

Progress

Background Initialization progress on %s is %s

Logged to inform Background Initialization progress in percentage of displayed LD.

0x0035

Information

Background Initialization started on %s

Logged to inform Background Initialization started for displayed LD.

0x0036

Information

Policy change on %s from %s to %s

Logged to inform the changed policy for displayed LD with old and new policies.

0x0038

Warning

Consistency Check aborted on %s

Logged to inform aborted Consistency check for displayed LD.

0x0039

Warning

Consistency Check corrected medium error (%s at %lx

Logged when Consistency check corrected medium error.

0x003a

Information

Consistency Check done on %s

Logged when Consistency check has completed successfully on the LD.

0x003b

Information

Consistency Check done with corrections on %s

Logged when Consistency check completed and inconsistency was found during check and was corrected.

0x003c

Fatal

Consistency Check detected uncorrectable double medium errors (%s at %lx on %s)

Logged when uncorrectable double medium error are detected while consistency check.

0x003d

Critical

Consistency Check failed on %s

Logged when Consistency check failed as fatal error was found.

0x003e

Fatal

Consistency Check completed with uncorrectable data on %s

Logged when Uncorrectable error occurred during consistency check.

0x003f

Warning

Consistency Check found inconsistent parity on %s at strip %lx

Logged when consistency check finds inconsistency parity on a strip.

0x0040

Warning

Consistency Check inconsistency logging disabled on %s (too many inconsistencies)

Logged when consistency check finds too many inconsistent parity (greater than 10) and the inconsistency parity logging is disabled.

0x0041

Progress

Consistency Check progress on %s is %s

Logs Consistency Check progress, the progress is logged only if the progress is greater than 1% at an interval of every 15 seconds.

0x0042

Information

Consistency Check started on %s

Logged when consistency check has started

0x0043

Warning

Initialization aborted on %s

Logged when consistency check is aborted by you or for some other reason.

0x0044

Critical

Initialization failed on %s

Logged when initialization has failed.

0x0045

Progress

Initialization progress on %s is %s

Logs initialization progress, the progress is logged only if the progress is greater than 1% at an interval of every 15 seconds.

0x0046

Information

Fast initialization started on %s

Logged when quick initialization has started on a LD. The parameter to decide Quick init or Full init is passed by you.

0x0047

Information

Full initialization started on %s

Logged when full initialization has started.

0x0048

Information

Initialization complete on %s

Logged when initialization has completed successfully.

0x0049

Information

LD Properties updated to %s (from %s)

Logged when LD properties has been changed.

0x004a

Information

Reconstruction complete on %s

Logged when reconstruction has completed successfully.

0x004b

Fatal

Reconstruction of %s stopped due to unrecoverable errors

Logged when reconstruction has finished because of failure (unrecoverable errors).

0x004c

Fatal

Reconstruct detected uncorrectable double medium errors (%s at %lx on %s at %lx)

Logged while reconstructing if an unrecoverable double medium error is encountered.

0x004d

Progress

Reconstruction progress on %s is %s

Logs reconstruction progress, the progress is logged only if the progress is greater than 1% at an interval of every 15 seconds.

0x004e

Information

Reconstruction resumed on %s

Logged when reconstruction resumes after a power cycle.

0x004f

Fatal

Reconstruction resume of %s failed due to configuration mismatch

Logged when reconstruction resume failed due to configuration mismatch.

0x0050

Information

Reconstruction started on %s

Logged on start of reconstruction on a LD.

0x0051

Information

State change on %s from %s to %s

Logged when there is change in LD state. The event gives the new and old state. The state could be one of the following, LDS_OFFLINE, LDS_PARTIALLY_DEGRADED, LDS_DEGRADED, LDS_OPTIMAL.

0x0052

Information

Drive Clear aborted on %s

Logged when PD clear is aborted.

0x0053

Critical

Drive Clear failed on %s (Error %02x)

Logged when drive clear is failed and the even is logged along with error code.

0x0054

Progress

Drive Clear progress on %s is %s

Logs drive clear progress, the progress is logged only if the progress is greater than 1% at an interval of every 15 seconds.

0x0055

Information

Drive Clear started on %s

Logged when drive clear started on a PD.

0x0056

Information

Drive Clear completed on %s

Logged when PD clear task is completed successfully on a PD.

0x0057

Warning

Error on %s (Error %02x)

Logged if Read returns with Uncorrectable error or same errors on both the drives or write long returns with an error (ie. puncture operation could failed).

0x0058

Information

Format complete on %s

Logged when Format has completed.

0x0059

Information

Format started on %s

Logged when format unit is started on a PD.

0x005a

Critical

Hot Spare SMART polling failed on %s (Error %02x)

Currently not logged.

0x005b

Information

Drive inserted: %s

Logged when drive is inserted and slot/enclosure fields of PD are updated.

0x005c

Warning

Drive %s is not supported

Logged when the drive is not supported; reason could be the number of drive has exceeded the MAX supported drives or an unsupported drive is inserted like a SATA drive in SAS only enclosure or could be a unsupported drive type.

0x005d

Warning

Patrol Read corrected medium error on %s at %lx

Logged when Patrol read has successfully completed recovery read and recovered data.

0x005e

Progress

Patrol Read progress on %s is %s

Logs patrol read progress, the progress is logged only if the progress is greater than 1% at an interval of every 15 seconds.

0x005f

Fatal

Patrol Read found an uncorrectable medium error on %s at %lx

Logged when Patrol read is unable to recover data.

0x0060

Critical

Predictive failure: CDB: %s

Logged when a failure is found during smart (predictive failure) poll.

0x0061

Fatal

Patrol Read puncturing bad block on %s at %lx

Logged when patrol read punctures a block due to unrecoverable medium error.

0x0062

Information

Rebuild aborted by user on %s

Logged when the user aborts a rebuild operation.

0x0063

Information

Rebuild complete on %s

Logged when the rebuild operation on a logical drive on a physical drive (which may have multiple LDs) is completed.

0x0064

Information

Rebuild complete on %s

Logged when rebuild operation is completed for all logical drives on a given physical drive.

0x0065

Critical

Rebuild failed on %s due to source drive error

Logged if one of the source drives for the rebuild operation fails or is removed.

0x0066

Critical

Rebuild failed on %s due to target drive error

Logged if the target rebuild drive (on which rebuild operation is going on) fails or is removed from the controller.

0x0067

Progress

Rebuild progress on %s is %s

Logged to indicate the progress (in percentage) of the rebuild operation on a given physical drive.

0x0068

Information

Rebuild resumed on %s

Logged when the rebuild operation on a physical drive resumes.

0x0069

Information

Rebuild started on %s

Logged when the rebuild operation is started on a physical drive.

0x006a

Information

Rebuild automatically started on %s

Logged when the rebuild operation kicks in on a spare.

0x006b

Critical

Rebuild stopped on %s due to loss of cluster ownership

Logged when the rebuild operation is stopped due to loss of ownership.

0x006c

Fatal

Reassign write operation failed on %s at %lx

Logged when a check condition or medium error is encountered for a reassigned write.

0x006d

Fatal

Unrecoverable medium error during rebuild on %s at %lx

Logged when the rebuild I/O encounters an unrecoverable medium error.

0x006e

Information

Corrected medium error during recovery on %s at %lx

Logged when recovery completed successfully and fixed a medium error.

0x006f

Fatal

Unrecoverable medium error during recovery on %s at %lx

Logged when the recovery for a failed I/O encounters a medium error.

0x0070

Information

Drive removed: %s

Logged when a drive is removed from the controller.

0x0071

Warning

Unexpected sense: %s, CDB%s, Sense: %s

Logged when an I/O fails due to unexpected reasons and sense data needs to be logged.

0x0072

Information

State change on %s from %s to %s

Logged when the state of a drive is changed by the firmware or by you.

0x0073

Information

State change by user on %s from %s to %s

Not logged by the firmware.

0x0074

Warning

Redundant path to %s broken

Not logged by the firmware.

0x0075

Information

Redundant path to %s restored

Not logged by the firmware

0x0076

Information

Dedicated Hot Spare Drive %s no longer useful due to deleted drive group

Not logged by the firmware.

0x0077

Critical

SAS topology error: Loop detected

Logged when device discovery fails for a SAS device as a loop was detected.

0x0078

Critical

SAS topology error: Unaddressable device

Logged when device discovery fails for a SAS device as an unaddressable device was found.

0x0079

Critical

SAS topology error: Multiple ports to the same SAS address

Logged when device discovery fails for a SAS device multiple ports with same SAS address were detected.

0x007a

Critical

SAS topology error: Expander error

Not logged by the firmware.

0x007b

Critical

SAS topology error: SMP timeout

Logged when device discovery fails for a SAS device due to SMP timeout.

0x007c

Critical

SAS topology error: Out of route entries

Logged when device discovery fails for a SAS device as expander route table is out of entries.

0x007d

Critical

SAS topology error: Index not found

Logged when device discovery fails for a SAS device as expander route table out of entries.

0x007e

Critical

SAS topology error: SMP function failed

Logged when device discovery fails for a SAS device due to SMP function failure.

0x007f

Critical

SAS topology error: SMP CRC error

Logged when device discovery fails for a SAS device due to SMP CRC error.

0x0080

Critical

SAS topology error: Multiple subtractive

Logged when device discovery fails for a SAS device as a subtractive-to-subtractive link was detected.

0x0081

Critical

SAS topology error: Table to table

Logged when device discovery fails for a SAS device as table-to-table link was detected.

0x0082

Critical

SAS topology error: Multiple paths

Not logged by the firmware.

0x0083

Fatal

Unable to access device %s

Logged when the inserted drive is bad and unusable.

0x0084

Information

Dedicated Hot Spare created on %s (%s)

Logged when a drive is configured as a dedicated spare.

0x0085

Information

Dedicated Hot Spare %s disabled

Logged when a drive is removes as a dedicated spare.

0x0086

Critical

Dedicated Hot Spare %s no longer useful for all drive groups

Logged when an array with a dedicated spare is resized. The hot spare (dedicated to this array and possibly others) will not be applicable to other arrays.

0x0087

Information

Global Hot Spare created on %s (%s)

Logged when a drive is configured as a global hot spare.

0x0088

Information

Global Hot Spare %s disabled

Logged when a drive configured as global host spare fails or is unconfigured by you.

0x0089

Critical

Global Hot Spare does not cover all drive groups

Logged when the global hotspare is too small (or doesn't meet the SAS/SATA restricitons) to cover certain arrays.

0x008a

Information

Created %s}

Logged as soon as the new logical drive created is added to the firmware configuration.

0x008b

Information

Deleted %s}

Logged when the firmware removes an LD from it's configuration upon a user request from the applications.

0x008c

Information

Marking LD %s inconsistent due to active writes at shutdown

Logged when we have active writes on one of the target disks of a Raid 5 LD at the time of shutdown.

0x008d

Information

Battery Present

Logged during firmware initialization when we check if there is a battery present and the check turns out true. This event is also logged when a battery is inserted or replaced with a new one and the battery present check returns true.

0x008e

Warning

Battery Not Present

Logged if the user has not disabled "Battery Not Present" warning at the boot time or if a battery has been removed.

0x008f

Information

New Battery Detected

Logged when we have a subsequent boot after a new battery has been inserted.

0x0090

Information

Battery has been replaced

Logged when a new battery has been replaced with an old battery.

0x0091

Critical

Battery temperature is high

Logged when we detect that the battery temperature is high during the periodic battery status check.

0x0092

Warning

Battery voltage low

Not logged by the firmware.

0x0093

Information

Battery started charging

Logged as part of monitoring the battery status when the battery is getting charged.

0x0094

Information

Battery is discharging

Logged as part of monitoring the battery status when the battery is getting discharged.

0x0095

Information

Battery temperature is normal

Logged as part of monitoring the battery status when the temperature of the battery is normal.

0x0096

Fatal

Battery has failed and cannot support data retention. Please replace the battery.

Logged when there is not enough capacity left in battery for expected data retention time. Battery has to be replaced.

0x0097

Information

Battery relearn started

logged when the battery relearn started, initiated either by the user or automatically.

0x0098

Information

Battery relearn in progress

Logged as part of monitoring the battery status when the battery relearn is in progress.

0x0099

Information

Battery relearn completed

Logged as part of monitoring the battery status when the battery relearn is complete.

0x009a

Critical

Battery relearn timed out

Not logged by the firmware.

0x009b

Information

Battery relearn pending: Battery is under charge

Logged as part of monitoring the battery status when the battery relearn is requested but yet to start.

0x009c

Information

Battery relearn postponed

Logged as part of monitoring the battery status when the battery relearn is requested but postponed as there is valid pinned cache present. This event can also be logged when learn delay interval has been explicitly set.

0x009d

Information

Battery relearn will start in 4 days

Logged as part of providing battery learn cycle information when auto learn is enabled.

0x009e

Information

Battery relearn will start in 2 day

Logged as part of providing battery learn cycle information when auto learn is enabled.

0x009f

Information

Battery relearn will start in 1 day

Logged as part of providing battery learn cycle information when auto learn is enabled.

0x00a0

Information

Battery relearn will start in 5 hours

Logged as part of providing battery learn cycle information when auto learn is enabled.

0x00a1

Information

Battery removed

Logged as part of periodic monitoring of the battery status when a battery has been removed.

0x00a2

Information

Current capacity of the battery is below threshold

Logged as part of monitoring the battery status when the capacity of the battery is below threshold.

0x00a3

Information

Current capacity of the battery is above threshold

Logged as part of monitoring the battery status when the capacity of the battery is above threshold.

0x00a4

Information

Enclosure (SES) discovered on %s

Logged when an Enclosure (SES) is discovered for the first time.

0x00a5

Information

Enclosure (SAFTE) discovered on %s

Not logged by the firmware.

0x00a6

Critical

Enclosure %s communication lost

Logged when the communication with an enclosure has been lost.

0x00a7

Information

Enclosure %s communication restored

Logged when the communication with an enclosure has been restored

0x00a8

Critical

Enclosure %s fan %d failed

Logged when an enclosure fan has failed.

0x00a9

Information

Enclosure %s fan %d inserted

Logged when an enclosure fan has been inserted newly.

0x00aa

Critical

Enclosure %s fan %d removed

Logged when an enclosure fan has been removed.

0x00ab

Critical

Enclosure %s power supply %d failed

Not logged by the firmware.

0x00ac

Information

Enclosure %s power supply %d inserted

Logged when power supply has been inserted to an enclosure.

0x00ad

Critical

Enclosure %s power supply %d removed

Logged when power supply has been removed from an enclosure.

0x00ae

Critical

Enclosure %s SIM %d failed

Logged when the enclosure SIM has failed.

0x00af

Information

Enclosure %s SIM %d inserted

Logged when an enclosure SIM has been inserted.

0x00b0

Critical

Enclosure %s SIM %d removed

Logged when an enclosure initialization was completed but later the SIM was removed.

0x00b1

Warning

Enclosure %s temperature sensor %d below warning threshold

Logged when the enclosure services process has detected a temperature lower than a normal operating temperature or lower than the value indicated by the LOW WARNING THRESHOLD field in the Threshold In diagnostic page.

0x00b2

Critical

Enclosure %s temperature sensor %d below error threshold

Logged when the enclosure services process has detected a temperature lower than a safe operating temperature or lower than the value indicated by the LOW CRITICAL THRESHOLD field in the Threshold In diagnostic page.

0x00b3

Warning

Enclosure %s temperature sensor %d above warning threshold

Logged when the enclosure services process has detected a temperature higher than a normal operating temperature or higher than the value indicated by the HIGH WARNING THRESHOLD field in the Threshold In diagnostic page.

0x00b4

Critical

Enclosure %s temperature sensor %d above error threshold

Logged when the enclosure services process has detected a temperature higher than a safe operating temperature or higher than the value indicated by the HIGH CRITICAL THRESHOLD field in the Threshold In diagnostic page.

0x00b5

Critical

Enclosure %s shutdown

Logged when an unrecoverable condition is detected in the enclosure.

0x00b6

Warning

Enclosure %s not supported; too many enclosures connected to port

Logged when the maximum allowed enclosures per port is exceeded.

0x00b7

Critical

Enclosure %s firmware mismatch

Logged when two ESMs have different firmware versions.

0x00b8

Warning

Enclosure %s sensor %d bad

Logged when the device is present on the phy, but the status does not indicate its presence.

0x00b9

Critical

Enclosure %s phy %d bad

Logged when the status indicates a device presence, but there is no corresponding SAS address is associated with the device.

0x00ba

Critical

Enclosure %s is unstable

Logged when the enclosure services process reports the sense errors.

0x00bb

Critical

Enclosure %s hardware error

Logged when a critical or an unrecoverable enclosure failure has been detected by the enclosure services process.

0x00bc

Critical

Enclosure %s not responding

Logged when there is no response from the enclosure.

0x00bd

Information

SAS/SATA mixing not supported in enclosure; Drive %s disabled

Logged when the SAS/SATA mixing in an enclosure is being violated.

0x00be

Information

Enclosure (SES) hotplug on %s was detected, but is not supported

Not reported to the user.

0x00bf

Information

Clustering enabled

Logged when the clustering is enabled in the controller properties.

0x00c0

Information

Clustering disabled

Logged when the clustering is disabled in the controller properties.

0x00c1

Information

Drive too small to be used for auto-rebuild on %s

Logged when the size of the drive is not sufficient for auto-rebuild.

0x00c2

Information

BBU enabled; changing WT virtual drives to WB

Logged when changing WT virtual drives to WB and the BBU status is good.

0x00c3

Warning

BBU disabled; changing WB virtual drives to WT

Logged when changing WB virtual drives to WT and the BBU status is bad.

0x00c4

Warning

Bad block table on drive %s is 80% full

Logged when the Bad block table on a drive is 80% full.

0x00c5

Fatal

Bad block table on drive %s is full; unable to log block %lx

Logged when the Bad block table on a drive is full and not able to add the bad block in the Bad block table.

0x00c6

Information

Consistency Check Aborted due to ownership loss on %s

Logged when the Consistency Check is aborted due to ownership is lost.

0x00c7

Information

Background Initialization (BGI) Aborted Due to Ownership Loss on %s

Logged when the Background Initialization (BGI) is aborted due to ownership loss.

0x00c8

Critical

Battery/charger problems detected; SOH Bad

Logged when the battery is not presented or removed and SOH is bad.

0x00c9

Warning

Single-bit ECC error: ECAR=%x, ELOG=%x, (%s); warning threshold exceeded

Logged when the Single-bit ECC errors exceeded the warning threshold.

0x00ca

Critical

Single-bit ECC error: ECAR=%x, ELOG=%x, (%s); critical threshold exceeded

Logged when the Single-bit ECC errors exceeded the critical threshold.

0x00cb

Critical

Single-bit ECC error: ECAR=%x, ELOG=%x, (%s); further reporting disabled

Logged when the Single-bit ECC errors exceeded all the thresholds and disable further logging.

0x00cc

Critical

Enclosure %s Power supply %d switched off

Logged when the enclosure services process has detected that the Enclosure Power supply is switched off and it was switched on earlier.

0x00cd

Information

Enclosure %s Power supply %d switched on

Logged when the enclosure services process has detected that the Enclosure Power supply is switched on and it was switched off earlier.

0x00ce

Critical

Enclosure %s Power supply %d cable removed

Logged when the enclosure services process has detected that the Enclosure Power supply cable is removed and it was inserted earlier.

0x00cf

Information

Enclosure %s Power supply %d cable inserted

Logged when the enclosure services process has detected that the Enclosure Power supply cable is inserted and it was removed earlier.

0x00d0

Information

Enclosure %s Fan %d returned to normal

Logged when the enclosure services process has detected that the current status of a fan is good and it was failed earlier.

0x00d1

Information

BBU Retention test was initiated on previous boot

Logged when the Battery Retention test was initiated on previous boot.

0x00d2

Information

BBU Retention test passed

Logged when the Battery Retention test passed successfully.

0x00d3

Critical

BBU Retention test failed!

Logged when the Battery Retention test failed.

0x00d4

Information

NVRAM Retention test was initiated on previous boot

Logged when the NVRAM Retention test was initiated on previous boot.

0x00d5

Information

NVRAM Retention test passed

Logged when the NVRAM Retention test passed successfully.

0x00d6

Critical

NVRAM Retention test failed!

Logged when the NVRAM Retention test failed.

0x00d7

Information

%s test completed %d passes successfully

Logged when the controller diagnostics test passes successfully.

0x00d8

Critical

%s test FAILED on %d pass. Fail data: errorOffset=%x goodData=%x badData=%x

Logged when the controller diagnostics test fails.

0x00d9

Information

Self check diagnostics completed

Logged when Self check diagnostics is completed.

0x00da

Information

Foreign Configuration detected

Logged when Foreign Configuration is detected.

0x00db

Information

Foreign Configuration imported

Logged when Foreign Configuration is imported.

0x00dc

Information

Foreign Configuration cleared

Logged when Foreign Configuration is cleared.

0x00dd

Warning

NVRAM is corrupt; reinitializing

Logged when NVRAM is corrupt and re-initialized.

0x00de

Warning

NVRAM mismatch occurred

Logged when NVRAM mismatch occurs.

0x00df

Warning

SAS wide port %d lost link on PHY %d

Logged when SAS wide port lost link on a PHY.

0x00e0

Information

SAS wide port %d restored link on PHY %d

Logged when a SAS wide port restored link on a PHY.

0x00e1

Warning

SAS port %d, PHY %d has exceeded the allowed error rate

Logged when a SAS PHY on port has exceeded the allowed error rate.

0x00e2

Warning

Bad block reassigned on %s at %lx to %lx

Logged when a Bad block is reassigned on a drive from a error sector to a new sector.

0x00e3

Information

Controller Hot Plug® detected

Logged when a Controller Hot Plug is detected.

0x00e4

Warning

Enclosure %s temperature sensor %d differential detected

Logged when an Enclosure temperature sensor differential is detected.

0x00e5

Information

Drive test cannot start. No qualifying drives found

Logged when Disk test cannot start. No qualifying disks found.

0x00e6

Information

Time duration provided by host is not sufficient for self check

Logged when Time duration provided by the host is not sufficient for self check.

0x00e7

Information

Marked Missing for %s on drive group %d row %d

Logged when a physical drive is Marked Missing on an array at a particular row.

0x00e8

Information

Replaced Missing as %s on drive group %d row %d

Logged when a physical drive is Replaced Missing on an array at a particular row.

0x00e9

Information

Enclosure %s Temperature %d returned to normal

Logged when an Enclosure temperature returns to normal.

0x00ea

Information

Enclosure %s Firmware download in progress

Logged when Enclosure a Firmware download is in progress.

0x00eb

Warning

Enclosure %s Firmware download failed

Logged when Enclosure a Firmware download failed.

0x00ec

Warning

%s is not a certified drive

Logged if the drive is not certified.

0x00ed

Information

Dirty cache data discarded by user

Logged when Dirty cache data is discarded by the user.

0x00ee

Information

Drives missing from configuration at boot

Logged when physical drives are missing from configuration at boot.

0x00ef

Information

Virtual drives (VDs) missing drives and will go offline at boot: %s

Logged when virtual drives missing drives and will go offline at boot.

0x00f0

Information

VDs missing at boot: %s

Logged when virtual drives missing at boot.

0x00f1

Information

Previous configuration completely missing at boot

Logged when Previous configuration completely missing at boot.

0x00f2

Information

Battery charge complete

Logged when Battery charge is completed.

0x00f3

Information

Enclosure %s fan %d speed changed

Logged when an Enclosure fan speed changed.

0x00f4

Information

Dedicated spare %s imported as global due to missing arrays

Logged when a Dedicated spare is imported as global due to missing arrays.

0x00f5

Information

%s rebuild not possible as SAS/SATA is not supported in an array

Logged when a rebuild is not possible as SAS/SATA is not supported in an array.

0x00f6

Information

SEP %s has been rebooted as a part of enclosure firmware download. SEP will be unavailable until this process completes.

Logged when SEP has been rebooted as part of enclosure firmware download. It will be unavailable until reboot completes.

0x00f7

Information

Inserted PD: %s Info: %s

Logged when a physical drive is inserted.

0x00f8

Information

Removed PD: %s Info: %s

Logged when a physical drive is removed.

0x00f9

Information

VD %s is now OPTIMAL

Logged when a logical drive state changes to OPTIMAL.

0x00fa

Warning

VD %s is now PARTIALLY DEGRADED

Logged when a logical drive state changes to a partially degraded state.

0x00fb

Critical

VD %s is now DEGRADED

Logged when a logical drive state changes to degraded state.

0x00fc

Fatal

VD %s is now OFFLINE

Logged when a logical drive state changes to offline state.

0x00fd

Warning

Battery requires reconditioning; please initiate a LEARN cycle

Logged when a Battery requires reconditioning; please initiate a LEARN cycle.

0x00fe

Warning

VD %s disabled because RAID-5 is not supported by this RAID key

Logged when a virtual drive is disabled because RAID-5 is not supported by this RAID key.

0x00ff

Warning

VD %s disabled because RAID-6 is not supported by this controller

Logged when a virtual drive is disabled because RAID-6 is not supported by this controller.

0x0100

Warning

VD %s disabled because SAS drives are not supported by this RAID key

Logged when a virtual drive is disabled because SAS drives are not supported by this RAID key.

0x0101

Warning

PD missing: %s

Logged to provide information about the missing drive during boot.

0x0102

Warning

Puncturing of LBAs enabled

Currently not logged in the firmware.

0x0103

Warning

Puncturing of LBAs disabled

Currently not logged in the firmware.

0x0104

Critical

Enclosure %s EMM %d not installed

Logged when Enclosure SIM is not installed.

0x0105

Information

Package version %s

Prints the Package version number.

0x0106

Warning

Global affinity Hot Spare %s commissioned in a different enclosure

Logged when a hot spare that is a part of an enclosure is commissioned in a different enclosure.

0x0107

Warning

Foreign configuration table overflow

Logged when the number of GUIDs to import exceeds the total supported by the firmware.

0x0108

Warning

Partial foreign configuration imported, PDs not imported:%s

Logged when all the foreign configuration drives could not be imported.

0x0109

Information

Connector %s is active

Logged during initial boot when a SAS MUX connector is found for the controller.

0x010a

Information

Board Revision %s

Logged during boot.

0x010b

Warning

Command timeout on PD %s, CDB:%s

Logged when command to a PD Timesout.

0x010c

Warning

PD %s reset (Type %02x)

Logged when PD is reset.

0x010d

Warning

VD bad block table on %s is 80% full

Logged when number of Bad Blocks entries is at 80 % of what can be supported in the firmware.

0x010e

Fatal

VD bad block table on %s is full; unable to log block %lx (on %s at %lx)

Logged when number of Bad Blocks exceed what can be supported in the firmware.

0x010f

Fatal

Uncorrectable medium error logged for %s at %lx (on %s at %lx)

Logged when an uncorrectable medium error is detected.

0x0110

Information

VD medium error corrected on %s at %lx

Logged on the corrected medium error.

0x0111

Warning

Bad block table on PD %s is 100% full

Logged when Bad block table is 100 % Full. Any more media errors on this physical drive will not be logged in the bad block table.

0x0112

Warning

VD bad block table on PD %s is 100% full

Logged when Bad block table is 100 % Full. Any more media errors on this logical drive will not be logged in the bad block table.

0x0113

Fatal

Controller needs replacement, IOP is faulty

Currently not logged in the firmware.

0x0114

Information

Replace Drive started on PD %s from PD %s

Logged when Replace is started.

0x0115

Information

Replace Drive aborted on PD %s and src is PD %s

Logged when Replace is aborted.

0x0116

Information

Replace Drive complete on PD %s from PD %s

Logged when Replace is completed.

0x0117

Progress

Replace Drive progress on PD %s is %s

Logged to provide the progress of Replace.

0x0118

Information

Replace Drive resumed on PD %s from %s

Logged when Replace operation is resumed.

0x0119

Information

Replace Drive automatically started on PD %s from %s

Logged on automatic start of Replace.

0x011a

Critical

Replace Drive failed on PD %s due to source %s error

Logged when the source physical drive of a Replace fails. The Replace stops and rebuild starts on the destination physical drive.

0x011b

Warning

Early Power off warning was unsuccessful

Currently not logged in the firmware.

0x011c

Information

BBU FRU is %s

Logged only for IBM.

0x011d

Information

%s FRU is %s

Logged if FRU data is present. Logged only for IBM.

0x011e

Information

Controller hardware revision ID %s

Currently not used in the firmware.

0x011f

Warning

Foreign import shall result in a backward incompatible upgrade of configuration metadata

Currently not used in the firmware.

0x0120

Information

Redundant path restored for PD %s

Logged when new path is added for the physical drives.

0x0121

Warning

Redundant path broken for PD %s

Logged when one path is removed.

0x0122

Information

Redundant enclosure EMM %s inserted for EMM %s

Logged when an enclosure is added.

0x0123

Information

Redundant enclosure EMM %s removed for EMM %s

Logged when an enclosure is removed

0x0124

Warning

Patrol Read can't be started, as PDs are either not ONLINE, or are in a VD with an active process, or are in an excluded VD

Logged when none of the disks can start PR.

0x0125

Information

Replace Drive aborted by user on PD %s and src is PD %s

Logged when Replace is aborted by the user.

0x0126

Critical

Replace Drive aborted on hot spare %s from %s, as hot spare needed for rebuild

Logged when Replace is aborted on a Hotspare.

0x0127

Warning

Replace Drive aborted on PD %s from PD %s, as rebuild required in the array

Logged when Replace is stopped for a higher priority rebuild operation on a drive.

0x0128

Fatal

Controller cache discarded for missing or offline VD %s

When a VD with cached data goes offline or missing during runtime, the cache for the VD is discarded. Because the VD is offline, the cache cannot be saved.

Logged when pinned cache lines are discarded for a LD.

0x0129

Information

Replace Drive cannot be started as PD %s is too small for src PD %s

Logged when destination PD is too small for Replace.

0x012a

Information

Replace Drive cannot be started on PD %s from PD %s, as SAS/SATA is not supported in an array

Logged when there is a SAS/SATA mixing violation for the destination PD.

0x012b

Information

Microcode update started on PD %s

Logged when PD Firmware download starts.

0x012c

Information

Microcode update completed on PD %s

Logged when PD Firmware download completes.

0x012d

Warning

Microcode update timeout on PD %s

Logged when PD Firmware download does not complete and times out.

0x012e

Warning

Microcode update failed on PD %s

Logged when PD Firmware download fails.

0x012f

Information

Controller properties changed

Logged when any of the controller properties has changed.

0x0130

Information

Patrol Read properties changed

Currently not logged in the firmware.

0x0131

Information

CC Schedule properties changed

Logged when consistency check scheduling property has changed.

0x0132

Information

Battery properties changed

Logged when any of the BBU properties has changed.

0x0133

Warning

Periodic Battery Relearn is pending. Please initiate manual learn cycle as Automatic learn is not enabled

Logged when BBU periodic relearn is pending.

0x0134

Information

Drive security key created

Logged when controller lock key is created.

0x0135

Information

Drive security key backed up

Logged when controller lock key is backed up.

0x0136

Information

Drive security key from escrow, verified

Logged when controller lock key is verified from escrow.

0x0137

Information

Drive security key changed

Logged when controller lock key is re-keyed.

0x0138

Warning

Drive security key, re-key operation failed

Logged when controller lock re-key operation failed.

0x0139

Warning

Drive security key is invalid

Logged when the controller lock is not valid.

0x013a

Information

Drive security key destroyed

Logged when the controller lock key is destroyed.

0x013b

Warning

Drive security key from escrow is invalid

Logged when the controller escrow key is not valid. This escrow key can not unlock any drive.

0x013c

Information

VD %s is now secured

Logged when secure LD is created.

0x013d

Warning

VD %s is partially secured

Logged when all the drives in the array are not secure.

0x013e

Information

PD %s security activated

Logged when PD security key is set.

0x013f

Information

PD %s security disabled

Logged when security key is removed from an FDE drive.

0x0140

Information

PD %s is reprovisioned

Logged when PD security is cleared.

0x0141

Information

PD %s security key changed

Logged when PD lock key is re-keyed.

0x0142

Fatal

Security subsystem problems detected for PD %s

Logged when PD security can not be set.

0x0143

Fatal

Controller cache pinned for missing or offline VD %s

Logged when LD cache is pinned.

0x0144

Fatal

Controller cache pinned for missing or offline VDs: %s

Logged when pinned cache is found during OCR.

0x0145

Information

Controller cache discarded by user for VDs: %s

Logged when LD pinned cache is discarded by the user.

0x0146

Information

Controller cache destaged for VD %s

Logged when LD pinned cache is recovered.

0x0147

Warning

Consistency Check started on an inconsistent VD %s

Logged when consistency check is started on an inconsistent LD.

0x0148

Warning

Drive security key failure, cannot access secured configuration

Logged when an invalid lock key is detected.

0x0149

Warning

Drive security password from user is invalid

Not logged.

0x014a

Warning

Detected error with the remote battery connector cable

Not logged.

0x014b

Information

Power state change on PD %s from %s to %s

Logged when PD power state (spun up, spun down, in-transition) changes.

0x014c

Information

Enclosure %s element (SES code 0x%x) status changed

Not logged.

0x014d

Information

PD %s rebuild not possible as HDD/CacheCade software mix is not supported in a drive group

Logged when mixing violation occurs due to HDD/SSD mismatch.

0x014e

Information

Replace Drive cannot be started on PD %s from %s, as HDD/CacheCade software mix is not supported in a drive group

Logged when Replace could not be started on a PD because HDD/CacheCade software mix was not supported in a drive group.

0x014f

Information

VD bad block table on %s is cleared

Logged when a VD bad block table was cleared.

0x0150

Caution

SAS topology error: 0x%lx

Logged when a SAS topology error occurred.

0x0151

Information

VD cluster of medium errors corrected for %s at %lx (on %s at %lx)

Logged when medium errors were corrected for a PD for a LD.

0x0152

Information

Controller requests a host bus rescan

Logged when controller requested a host bus rescan.

0x0153

Information

Controller repurposed and factory defaults restored

Logged when controller repurposed and factory defaults were restored.

0x0154

Information

Drive security key binding updated

Logged when drive security key binding was updated.

0x0159

Critical

Controller encountered a fatal error and was reset

Logged when a controller encountered a fatal error and was reset.

0x015a

Information

Snapshots enabled on %s (Repository %s)

Logged when snapshot was enabled on a LD.

0x015b

Information

Snapshots disabled on %s (Repository %s) by the user

Logged when snapshot was disabled on a LD by the user.

0x015c

Critical

Snapshots disabled on %s (Repository %s), due to a fatal error

Logged when snapshot was disabled on a LD due to a fatal error.

0x015d

Information

Snapshot created on %s at %s

Logged when snapshot was created on a LD.

0x015e

Information

Snapshot deleted on %s at %s

Logged when snapshot was deleted on a LD.

0x015f

Information

View created at %s to a snapshot at %s for %s

Logged when view was created at a LD.

0x0160

Information

View at %s is deleted, to snapshot at %s for %s

Logged when View at a LD was deleted

0x0161

Information

Snapshot rollback started on %s from snapshot at %s

Logged when snapshot rollback was started on a LD.

0x0162

Fatal

Snapshot rollback on %s internally aborted for snapshot at %s

Logged when snapshot rollback was internally aborted.

0x0163

Information

Snapshot rollback on %s completed for snapshot at %s

Logged when snapshot rollback on a LD was completed.

0x0164

Information

Snapshot rollback progress for snapshot at %s, on %s is %s

Logged to report snapshot rollback progress on a LD.

0x0165

Warning

Snapshot space for %s in snapshot repository %s, is 80%% full

Logged when snapshot space for a LD in a snapshot repository was 80% full.

0x0166

Critical

Snapshot space for %s in snapshot repository %s, is full

Logged when snapshot space for a LD in a snapshot repository was full.

0x0167

Warning

View at %s to snapshot at %s, is 80%% full on snapshot repository %s

Logged when view at a LD to a snapshot was 80% full on a snapshot repository.

0x0168

Critical

View at %s to snapshot at %s, is full on snapshot repository %s

Logged when view at a LD to a snapshot was full on a snapshot repository.

0x0169

Critical

Snapshot repository lost for %s

Logged when snapshot repository was lost for a LD.

0x016a

Warning

Snapshot repository restored for %s

Logged when snapshot repository was restored for a LD.

0x016b

Critical

Snapshot encountered an unexpected internal error: 0x%lx

Logged when snapshot encountered an unexpected internal error.

0x016c

Information

Auto Snapshot enabled on %s (snapshot repository %s)

Logged when auto snapshot was enabled.

0x016d

Information

Auto Snapshot disabled on %s (snapshot repository %s)

Logged when auto Snapshot was disabled.

0x016e

Critical

Configuration command could not be committed to disk, please retry

Logged when configuration command could not be committed to disk and was asked to retry.

0x016f

Information

COD on %s updated as it was stale

Logged when COD in DDF is updated due to various reasons.

0x0170

Warning

Power state change failed on %s (from %s to %s)

Logged when power state change failed on a PD.

0x0171

Warning

%s is not available

Logged when a LD was not available.

0x0172

Information

%s is available

Logged when a LD was available.

0x0173

Information

%s is used for CacheCade with capacity 0x%lx logical blocks

Logged when a LD was used for CacheCade with the indicated capacity in logical blocks.

0x0174

Information

%s is using CacheCade %s

Logged when a LD was using CacheCade.

0x0175

Information

%s is no longer using CacheCade %s

Logged when a LD was no longer using CacheCade.

0x0176

Critical

Snapshot deleted due to resource constraints for %s in snapshot repository %s

Logged when the snapshot is deleted due to resource constraints in snapshot repository.

0x0177

Warning

Auto Snapshot failed for %s in snapshot repository %s

Logged when the Auto Snapshot is failed for a VD in snapshot repository.

0x0178

Warning

Controller reset on-board expander

Logged when the chip reset issued to on-board expander.

0x0179

Warning

CacheCade (%s) capacity changed and is now 0x%lx logical blocks

Logged when the CacheCade capacity is changed along with the current capacity.

0x017a

Warning

Battery cannot initiate transparent learn cycles

Logged when the Battery cannot initiate transparent learn cycles.

0x017b

Information

Premium feature %s key was applied for - %s

Logged when the Premium feature key was applied.

0x017c

Information

Snapshot schedule properties changed on %s

Logged when the Snapshot schedule properties changed.

0x017d

Information

Snapshot scheduled action is due on %s

Logged when the Snapshot scheduled action is due.

0x017e

Information

Performance Metrics: collection command 0x%lx

Logged during the Performance Metrics collection.

0x017f

Information

Premium feature %s key was transferred - %s

Logged when the Premium feature key was transferred.

0x0180

Information

Premium feature serial number %s

Logged when displaying the Premium feature serial number.

0x0181

Warning

Premium feature serial number mismatched. Key-vault serial num - %s

Logged when Premium feature serial number mismatched.

0x0182

Warning

Battery cannot support data retention for more than %d hours. Please replace the battery

Logged during the Battery monitoring and it displays the remaining data retention time of the battery.

0x0183

Information

%s power policy changed to %s (from %s)

Logged when the power policy of an LD is changed.

0x0184

Warning

%s cannot transition to max power savings

Logged when LD cannot transition to max power savings.

0x0185

Information

Host driver is loaded and operational

This event is not reported to the user.

0x0186

Information

%s mirror broken

Logged when the mirror is broken for an LD.

0x0187

Information

%s mirror joined

Logged when joining the LD with its broken mirror.

0x0188

Warning

%s link %d failure in wide port

This event is not reported to the user.

0x0189

Information

%s link %d restored in wide port

This event is not reported to the user.

0x018a

Information

Memory module FRU is %s

This event is not reported to the user.

0x018b

Warning

Cache-vault power pack is sub-optimal. Please replace the pack

This event is not reported to the user.

0x018c

Warning

Foreign configuration auto-import did not import any drives

Logged when the Foreign configuration auto-import did not import any drives.

0x018d

Warning

Cache-vault microcode update required

Logged when the BMU is not in Normal mode and Cache-vault microcode update required.

0x018e

Warning

CacheCade (%s) capacity exceeds maximum allowed size, extra capacity is not used

Logged when CacheCade capacity exceeds maximum allowed size, extra capacity is not used.

0x018f

Warning

LD (%s) protection information lost

Logged when the protection information is lost for an LD.

0x0190

Information

Diagnostics passed for %s

Logged when the SHIELD™ Diagnostics passed for a PD.

0x0191

Critical

Diagnostics failed for %s

Logged when the SHIELD Diagnostics failed for a PD.

0x0192

Information

Server Power capability Diagnostic Test Started

Logged when the Server Power capability Diagnostic Test starts.

0x0193

Information

Drive Cache settings enabled during rebuild for %s

Logged when the Drive Cache settings enabled during rebuild for a PD.

0x0194

Information

Drive Cache settings restored after rebuild for %s

Logged when the Drive Cache settings restored after rebuild for a PD.

0x0195

Information

Drive %s commissioned as Emergency spare

Logged when the Drive commissioned as Emergency spare.

0x0196

Warning

Reminder: Potential non-optimal configuration due to drive %s commissioned as emergency spare

Logged when the PD being imported is an Emergency Spare.

0x0197

Information

Consistency Check suspended on %s

Logged when the Consistency Check is suspended on an LD.

0x0198

Information

Consistency Check resumed on %s

Logged when the Consistency Check is resumed on an LD.

0x0199

Information

Background Initialization suspended on %s

Logged when the Background Initialization is suspended on an LD.

0x019a

Information

Background Initialization resumed on %

Logged when the Background Initialization is resumed on an LD.

0x019b

Information

Reconstruction suspended on %s

Logged when the Reconstruction is suspended on an LD.

0x019c

Information

Rebuild suspended on %

Logged when the Rebuild is suspended on a PD.

0x019d

Information

Replace Drive suspended on %s

Logged when the Replace is suspended on a PD.

0x019e

Information

Reminder: Consistency Check suspended on %

Logged as a reminder when the Consistency Check is suspended on an LD.

0x019f

Information

Reminder: Background Initialization suspended on %s

Logged as a reminder when the Background Initialization is suspended on an LD.

0x01a0

Information

Reminder: Reconstruction suspended on %s

Logged as a reminder when the Reconstruction is suspended on an LD.

0x01a1

Information

Reminder: Rebuild suspended on %s

Logged as a reminder when the Rebuild is suspended on a PD.

0x01a2

Information

Reminder: Replace Drive suspended on %s

Logged as a reminder when Replace is suspended on a PD.

0x01a3

Information

Reminder: Patrol Read suspended

Logged as a reminder when the Patrol Read is suspended.

0x01a4

Information

Erase aborted on %s

Logged when the Erase is aborted on a PD.

0x01a5

Critical

Erase failed on %s (Error %02x)

Logged when the Erase is failed on a PD along with the error.

0x01a6

Progress

Erase progress on %s is %s

Logged to display the Erase progress on a PD along with its current progress.

0x01a7

Information

Erase started on %s

Logged when Erase is started on a PD.

0x01a8

Information

Erase completed on %s

Logged when the Erase is completed on a PD.

0x01a9

Information

Erase aborted on %s

Logged when the Erase is aborted on an LD.

0x01aa

Critical

Erase failed on %s

Logged when the Erase is failed on an LD.

0x01ab

Progress

Erase progress on %s is %s

Logged to display the Erase progress on an LD along with its current progress.

0x01ac

Information

Erase started on %s

Logged when the Erase is started on an LD.

0x01ad

Information

Erase complete on %s

Logged when the Erase is complete on an LD.

0x01ae

Warning

Potential leakage during erase on %s

Logged to inform the Potential leakage during erase on an LD.

0x01af

Warning

Battery charging was suspended due to high battery temperature

Logged when the Battery charging was suspended due to high battery temperature.

0x01b0

Information

NVCache firmware update was successful

This event is not reported to the user.

0x01b1

Warning

NVCache firmware update failed

This event is not reported to the user.

0x01b2

Fatal

%s access blocked as cached data in CacheCade is unavailable

This event is not reported to the user.

0x01b3

Information

CacheCade disassociate started on %s

This event is not reported to the user.

0x01b4

Information

CacheCade disassociate completed on %s

This event is not reported to the user.

0x01b5

Critical

CacheCade disassociate failed on %s

This event is not reported to the user.

0x01b6

Progress

CacheCade disassociate progress on %s is %s

This event is not reported to the user.

0x01b7

Information

CacheCade disassociate aborted by user on %s

This event is not reported to the user.

0x01b8

Information

Link speed changed on SAS port %d and PHY %d

Logged when the Link speed changed on SAS port and PHY.

0x01b9

Warning

Advanced Software Options was deactivated for - %s

This event is not reported to the user.

0x01ba

Information

%s is now accessible

This event is not reported to the user.

0x01bb

Information

%s is using CacheCade

This event is not reported to the user.

0x01bc

Information

%s is no longer using CacheCade

This event is not reported to the user.

0x01bd

Warning

Patrol Read aborted on %s

Logged when the Patrol Read is aborted on a PD.

0x01c2

Information

Periodic Battery Relearn was missed, and rescheduled to %s

Logged if Battery Relearn was missed at the scheduled time due to a system power off then the controller will reschedule automatically when you power on the system.

0x01c3

Information

Controller reset requested by host

Logged when the Controller Reset process started on the corresponding controller.

0x01c4

Information

Controller reset requested by host, completed

Logged when the Controller Reset process completed on the corresponding controller.

0x01c7

Warning

Controller booted in headless mode with errors

Logged when the Controller is booted to safe mode due to warning errors.

0x01c8

Critical

Controller booted to safe mode due to critical errors

Logged when the Controller is booted to safe mode due to critical errors.

0x01c9

Warning

Warning Error during boot - %s

Logged when a warning error occurs during booting the controller to safe mode.

0x01ca

Critical

Critical Error during boot - %s

Logged when a critical error occurs during booting the controller to safe mode

0x01cb

Fatal

Fatal Error during boot - %s

Logged when a fatal error occurs during booting the controller to safe mode